Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Strahlenther Onkol ; 199(10): 922-935, 2023 10.
Article in English | MEDLINE | ID: mdl-37278833

ABSTRACT

PURPOSE: Total marrow lymphoid irradiation (TMLI) with volumetric modulated arc therapy (VMAT) is challenging due to large treatment fields with multiple isocenters, field matching at junctions, and targets being surrounded by many organs at risk. This study aimed to describe our methodology for safe dose escalation and accurate dose delivery of TMLI treatment with the VMAT technique based on early experience at our center. MATERIALS AND METHODS: Computed tomography (CT) scans were acquired in head-first supine and feet-first supine orientations for each patient with an overlap at mid-thigh. VMAT plans were generated for 20 patients on the head-first CT images with either three or four isocenters in the Eclipse treatment planning system (Varian Medical Systems Inc., Palo Alto, CA) and the treatment was delivered in a Clinac 2100 C/D linear accelerator (Varian Medical Systems Inc., Palo Alto, CA). RESULTS: Five patients were treated with a prescription dose of 13.5 Gy in 9 fractions and 15 patients were treated with an escalated dose of 15 Gy in 10 fractions. The mean doses to 95% of the clinical target volume (CTV) and planning target volume (PTV) were 14.3 ± 0.3 Gy and 13.6 ± 0.7 Gy for the prescription doses of 15 Gy, and 13 ± 0.2 Gy and 12.3 ± 0.3 Gy for the prescription doses of 13.5 Gy, respectively. Mean dose to the lung in both schedules was 8.7 ± 0.6 Gy. The overall time taken to execute the treatment plans was approximately 2 h for the first fraction and 1.5 h for subsequent fractions. The average in-room time of 15.5 h per patient over 5 days leads to potential changes in the regular treatment schedules for other patients. CONCLUSION: This feasibility study highlights the methodology adopted for safe implementation of TMLI with the VMAT technique at our institution. Escalation of dose to the target with adequate coverage and sparing of critical structures was achieved with the adopted treatment technique. Clinical implementation of this methodology at our center could serve as a practical guide to start the VMAT-based TMLI program safely by others who are keen to start this service.


Subject(s)
Radiotherapy, Intensity-Modulated , Humans , Bone Marrow/radiation effects , Feasibility Studies , Lymphatic Irradiation , Organs at Risk/radiation effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL
...