Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Cardiol ; 21(10): 769-71, 1998 Oct.
Article in English | MEDLINE | ID: mdl-9789701

ABSTRACT

This paper reports a patient in atrial flutter who spontaneously converted to sinus rhythm while undergoing a transesophageal echocardiogram. Atrial appendage flow velocities were noted to be significantly decreased after conversion to sinus rhythm. Spontaneous contrast also developed in the left atrium shortly after conversion. Spontaneous cardioversion may be associated with decreased mechanical activity of the left atrium and appendage, resulting in "stunning." This provides a possible explanation for the occurrence of thromboembolic events in patients without apparent thrombus before cardioversion.


Subject(s)
Atrial Flutter , Atrial Function, Left , Atrial Flutter/diagnosis , Atrial Flutter/physiopathology , Echocardiography, Transesophageal , Heart Atria/physiopathology , Humans , Male , Middle Aged , Ultrasonography, Doppler, Pulsed
2.
Am Heart J ; 136(4 Pt 1): 724-33, 1998 Oct.
Article in English | MEDLINE | ID: mdl-9778078

ABSTRACT

BACKGROUND: Accurate identification of patients at high risk for acute coronary syndromes among those seen in the emergency department (ED) with possible myocardial ischemia and nonischemic electrocardiograms is problematic. Both 2-dimensional echocardiography and myocardial perfusion imaging with technetium-99m sestamibi can identify patients at low and high risk; however, comparative studies are lacking. METHODS AND RESULTS: Patients initially considered at low or moderate risk for myocardial ischemia on the basis of the presenting history, physical examination, and electrocardiogram underwent both echocardiography and myocardial perfusion imaging within 4 hours of ED presentation. Positive echocardiography was defined as the presence of segmental wall motion abnormalities or moderate to severe global systolic dysfunction; positive perfusion imaging was defined as a perfusion defect in association with abnormal wall motion, thickening, or both. End points included MI, percutaneous transluminal coronary angioplasty, and positive stress perfusion imaging. Both imaging procedures were performed in the ED on 185 patients. Six patients had MI, and an additional 4 patients underwent percutaneous transluminal coronary angioplasty. Echocardiography and perfusion imaging were positive in all 10. Overall agreement between the 2 techniques was high (concordance 89%, kappa coefficient 0.74) in the 27 patients who had MI or underwent coronary angiography. For all patients, concordance was 89%, with a kappa coefficient of 0.66. CONCLUSIONS: Agreement between echocardiography and perfusion imaging with technetium-99m sestamibi is high when used in patients in the ED with possible myocardial ischemia. Both techniques identified patients at high risk who required admission and those who could be safely discharged directly from the ED.


Subject(s)
Echocardiography, Doppler , Myocardial Infarction/diagnostic imaging , Radiopharmaceuticals , Technetium Tc 99m Sestamibi , Adult , Aged , Confounding Factors, Epidemiologic , Echocardiography, Doppler/methods , Electrocardiography , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Radionuclide Imaging , Sensitivity and Specificity , Virginia
3.
Ann Emerg Med ; 31(5): 550-7, 1998 May.
Article in English | MEDLINE | ID: mdl-9581137

ABSTRACT

STUDY OBJECTIVE: Accurate diagnosis in emergency department patients with possible myocardial ischemia is problematic. Two-dimensional echocardiography has a high sensitivity for identifying patients with myocardial infarction (MI); however, few studies have investigated its diagnostic ability when used acutely in ED patients with possible myocardial ischemia. Therefore we investigated the ability of ED echocardiography for predicting cardiac events in patients with possible myocardial ischemia. METHODS: Echocardiography was performed within 4 hours of ED presentation in 260 patients with possible myocardial ischemia, and was considered positive if there were segmental wall motion abnormalities or the ejection fraction was less than 40%. ECGs were considered abnormal if there was an ST-segment elevation or depression of greater than or equal to 1 mm, or ischemic T-wave inversion. Cardiac events included MI and revascularization. RESULTS: Of the 260 patients studied, 45 had cardiac events (23 MI, 19 percutaneous transluminal angioplasty, 3 coronary bypass surgery). The sensitivity of echocardiography for predicting cardiac events was 91% (95% confidence interval 79% to 97%]), which was significantly higher than the ECG (40% [95% CI 27% to 55%]: P < .0001), although specificity was lower (75% [95% CI 69% to 81%] versus 94% [95% CI 90% to 97%]; P < .001). Addition of the echocardiography results to baseline clinical variables and the ECG added significant incremental diagnostic value (P < .001). With use of multivariate analysis, only male gender (P < .03, odds ratio [OR] 2.4 [1.1 to 5.3]), and a positive echocardiographic finding (P < .0001, OR 24 [9 to 65]) predicted cardiac events. Excluding patients with abnormal ECGs (N = 30) did not affect sensitivity (85%) or specificity (74%) of echocardiography. CONCLUSION: Echocardiography performed in ED patients with possible myocardial ischemia identifies those who will have cardiac events, is more sensitive than the ECG, and has significant incremental value when added to baseline clinical variables and the ECG.


Subject(s)
Chest Pain/etiology , Myocardial Ischemia/complications , Myocardial Ischemia/diagnostic imaging , Aged , Echocardiography/standards , Electrocardiography , Emergency Service, Hospital , Female , Follow-Up Studies , Humans , Male , Middle Aged , Multivariate Analysis , Myocardial Ischemia/physiopathology , Reproducibility of Results , Sensitivity and Specificity , Stroke Volume , Time Factors
4.
Cathet Cardiovasc Diagn ; 29(2): 122-7, 1993 Jun.
Article in English | MEDLINE | ID: mdl-8348596

ABSTRACT

Dobutamine infusion was performed in 16 patients following cardiac catheterization, and non-invasive assessment was performed with thallium SPECT and echocardiography. Dobutamine thallium scintigraphy was abnormal in 93% of patients with significant coronary artery disease. In addition, individual epicardial vessel involvement was identified by a corresponding perfusion defect with 88% sensitivity and 93% specificity. Dobutamine echocardiography revealed segmental wall motion abnormalities in 62% of patients with significant coronary disease. However, in six patients baseline segmental wall motion abnormalities on echocardiography improved during dobutamine infusion. Dobutamine thallium SPECT is a safe and useful test for the detection and localization of coronary artery disease. Dobutamine echocardiography is less useful in screening for coronary disease, but may detect areas of abnormally functioning myocardium having retained viability.


Subject(s)
Coronary Disease/diagnosis , Dobutamine , Echocardiography , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Coronary Angiography , Coronary Circulation/drug effects , Coronary Circulation/physiology , Coronary Disease/physiopathology , Dobutamine/adverse effects , Echocardiography/drug effects , Exercise Test/drug effects , Female , Hemodynamics/drug effects , Hemodynamics/physiology , Humans , Infusions, Intravenous , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/physiopathology , Thallium Radioisotopes
5.
J Am Coll Cardiol ; 7(3): 681-7, 1986 Mar.
Article in English | MEDLINE | ID: mdl-3950245

ABSTRACT

Doppler echocardiographic characteristics of normally functioning Hancock and Björk-Shiley prostheses in the mitral and aortic positions were studied in 50 patients whose valvular function was considered normal by clinical evaluation. Doppler studies were also performed in 46 patients with suspected malfunction of Hancock and Björk-Shiley valves and who subsequently underwent cardiac catheterization. Mean gradients were estimated for both mitral and aortic valve prostheses and valve area was calculated for the mitral prostheses. Doppler prosthetic mitral valve gradient and valve area showed good correlation with values obtained with cardiac catheterization (r = 0.93 and 0.97, respectively) for both types of prosthetic valves. The correlation coefficient (r = 0.93) for mean prosthetic aortic valve gradient was also good, although Doppler echocardiography overestimated the mean gradient at lower degrees of obstruction. Regurgitation of Hancock and Björk-Shiley prostheses in the mitral and aortic positions was correctly diagnosed. These results suggest that Doppler echocardiography is a reliable method for the characterization of normal and abnormal prosthetic valve function.


Subject(s)
Bioprosthesis , Echocardiography , Heart Valve Prosthesis , Adult , Aged , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/physiopathology , Bioprosthesis/adverse effects , Blood Flow Velocity , Cardiac Catheterization , Heart Valve Prosthesis/adverse effects , Humans , Middle Aged , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Prosthesis Design
SELECTION OF CITATIONS