Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 100
Filter
1.
Korean J Radiol ; 25(6): 559-564, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38807337

ABSTRACT

Incidental pancreatic cystic lesions are a common challenge encountered by diagnostic radiologists. Specifically, given the prevalence of benign pancreatic cystic lesions, determining when to recommend aggressive actions such as surgical resection or endoscopic ultrasound with sampling is difficult. In this article, we review the common types of cystic pancreatic lesions including serous cystadenoma, intraductal papillary mucinous neoplasm, and mucinous cystic neoplasm with imaging examples of each. We also discuss high-risk or worrisome imaging features that warrant a referral to a surgeon or endoscopist and provid several examples of these features. These imaging features adhere to the latest guidelines from the International Consensus Guidelines, American Gastroenterological Association (2015), American College of Gastroenterology (2018), American College of Radiology (2010, 2017), and European Guidelines (2013, 2018). Our focused article addresses the imaging dilemma of managing incidental cystic pancreatic lesions, weighing the options between imaging follow-up and aggressive interventions.


Subject(s)
Incidental Findings , Pancreatic Cyst , Pancreatic Neoplasms , Humans , Pancreatic Cyst/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Diagnosis, Differential , Pancreas/diagnostic imaging , Pancreas/pathology , Tomography, X-Ray Computed/methods
3.
J Cannabis Res ; 5(1): 29, 2023 Jul 26.
Article in English | MEDLINE | ID: mdl-37496090

ABSTRACT

BACKGROUND: Hemp-derived delta-9 tetrahydrocannabinol (∆9 THC) products are freely available for sale across much of the USA, but the federal legislation allowing their sale places only minimal requirements on companies. Products must contain no more than 0.3% ∆9 THC by dry weight, but no limit is placed on overall dosage and there is no requirement that products are tested. However, some states-such as Colorado-specifically prohibit products created by "chemically modifying" a natural hemp component. METHODS: Fifty-three ∆9 THC products were ordered and submitted to InfiniteCAL laboratory for analysis. The lab analysis considered potency, the presence of impurities, and whether the ∆9 THC present was natural or converted from CBD. The presence of age verification, company-conducted testing, and warning labels was also considered. RESULTS: While 96.2% of products were under the legal ∆9 THC limit, 66.0% differed from their stated dosage by more than 10%, and although 84.9% provided a lab report to customers, 71.1% of these did not check for impurities. Additionally, 49% of products converted CBD to THC to achieve their levels, and only 15.1% performed age verification at checkout. CONCLUSIONS: Despite some positive findings, the results show that hemp ∆9 THC companies offer inaccurately labeled products that contain more THC than would be allowed in adult-use states. This raises serious issues around consumer safety, and consent when consuming intoxicating products. Steps to boost accountability for companies must be considered by either the industry or lawmakers if intoxicating hemp products are to remain on the market safely.

5.
JAMA ; 326(22): 2299-2311, 2021 Dec 14.
Article in English | MEDLINE | ID: mdl-34905026

ABSTRACT

IMPORTANCE: Acute appendicitis is the most common abdominal surgical emergency in the world, with an annual incidence of 96.5 to 100 cases per 100 000 adults. OBSERVATIONS: The clinical diagnosis of acute appendicitis is based on history and physical, laboratory evaluation, and imaging. Classic symptoms of appendicitis include vague periumbilical pain, anorexia/nausea/intermittent vomiting, migration of pain to the right lower quadrant, and low-grade fever. The diagnosis of acute appendicitis is made in approximately 90% of patients presenting with these symptoms. Laparoscopic appendectomy remains the most common treatment. However, increasing evidence suggests that broad-spectrum antibiotics, such as piperacillin-tazobactam monotherapy or combination therapy with either cephalosporins or fluroquinolones with metronidazole, successfully treats uncomplicated acute appendicitis in approximately 70% of patients. Specific imaging findings on computed tomography (CT), such as appendiceal dilatation (appendiceal diameter ≥7 mm), or presence of appendicoliths, defined as the conglomeration of feces in the appendiceal lumen, identify patients for whom an antibiotics-first management strategy is more likely to fail. CT findings of appendicolith, mass effect, and a dilated appendix greater than 13 mm are associated with higher risk of treatment failure (≈40%) of an antibiotics-first approach. Therefore, surgical management should be recommended in patients with CT findings of appendicolith, mass effect, or a dilated appendix who are fit for surgery, defined as having relatively low risk of adverse outcomes or postoperative mortality and morbidity. In patients without high-risk CT findings, either appendectomy or antibiotics can be considered as first-line therapy. In unfit patients without these high-risk CT findings, the antibiotics-first approach is recommended, and surgery may be considered if antibiotic treatment fails. In unfit patients with high-risk CT findings, perioperative risk assessment as well as patient preferences should be considered. CONCLUSIONS AND RELEVANCE: Acute appendicitis affects 96.5 to 100 people per 100 000 adults per year worldwide. Appendectomy remains first-line therapy for acute appendicitis, but treatment with antibiotics rather than surgery is appropriate in selected patients with uncomplicated appendicitis.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Appendectomy , Appendicitis , Acute Disease , Adult , Algorithms , Anti-Bacterial Agents/adverse effects , Appendectomy/adverse effects , Appendicitis/complications , Appendicitis/diagnosis , Appendicitis/drug therapy , Appendicitis/surgery , Humans , Recurrence , Rupture, Spontaneous , Symptom Assessment , Tomography, X-Ray Computed , Ultrasonography
6.
J Exp Biol ; 224(19)2021 10 01.
Article in English | MEDLINE | ID: mdl-34581401

ABSTRACT

An unavoidable consequence of aerobic metabolism is the production of reactive oxygen species (ROS). Mitochondria have historically been considered the primary source of ROS; however, recent literature has highlighted the uncertainty in primary ROS production sites and it is unclear how variation in mitochondrial density influences ROS-induced damage and protein turnover. Fish skeletal muscle is composed of distinct, highly aerobic red muscle and anaerobic white muscle, offering an excellent model system in which to evaluate the relationship of tissue aerobic capacity and ROS-induced damage under baseline conditions. The present study used a suite of indices to better understand potential consequences of aerobic tissue capacity in red and white muscle of the pinfish, Lagodon rhomboides. Red muscle had a 7-fold greater mitochondrial volume density than white muscle, and more oxidative damage despite also having higher activity of the antioxidant enzymes superoxide dismutase and catalase. The dominant protein degradation system appears to be tissue dependent. Lysosomal degradation markers and autophagosome volume density were greater in white muscle, while ubiquitin expression and 20S proteasome activity were significantly greater in red muscle. However, ubiquitin ligase expression was significantly higher in white muscle. Red muscle had a more than 2-fold greater rate of translation and total ATP turnover than white muscle, results that may be due in part to the higher mitochondrial density and the associated increase in oxidative damage. Together, these results support the concept that an elevated aerobic capacity is associated with greater oxidative damage and higher costs of protein turnover.


Subject(s)
Muscle, Skeletal , Oxidative Stress , Adenosine Triphosphate/metabolism , Animals , Mitochondria, Muscle/metabolism , Muscle, Skeletal/metabolism , Oxidation-Reduction , Reactive Oxygen Species/metabolism
7.
J Am Coll Radiol ; 16(6): 810-813, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30598415

ABSTRACT

Radiologists play a critical role in helping the health care system achieve greater value. Unfortunately, today radiology is often judged by simple "checkbox" metrics, which neither directly reflect the value radiologists provide nor the outcomes they help drive. To change this system, first, we must attempt to better define the elusive term value and, then, quantify the value of imaging through more relevant and meaningful metrics that can be more directly correlated with outcomes. This framework can further improve radiology's value by enhancing radiologists' integration into the care team and their engagement with patients. With these improvements, we can maximize the value of imaging in the overall care of patients.


Subject(s)
Delivery of Health Care/organization & administration , Practice Management, Medical/organization & administration , Prospective Payment System/economics , Radiologists/organization & administration , Efficiency, Organizational , Female , Humans , Male , Needs Assessment , Physician's Role , Radiology/organization & administration , United States
8.
J Am Coll Radiol ; 15(9): 1203-1204, 2018 09.
Article in English | MEDLINE | ID: mdl-30082234

Subject(s)
Radiography , Radiology
11.
Abdom Imaging ; 40(8): 2932-44, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26482048

ABSTRACT

Disease involving the pancreas can be a significant diagnostic challenge to the interpreting radiologist. Moreover, the majority of disease processes involving the pancreas carry high significant morbidity and mortality either due to their natural process or related to their treatment options. As such, it is critical for radiologists to not only provide accurate information from imaging to guide patient management, but also deliver that information in a clear manner so as to aid the referring physician. This is no better exemplified than in the case of pre-operative staging for pancreatic adenocarcinoma. Furthermore, with the changing healthcare landscape, it is now more important than ever to ensure that the value of radiology service to other providers is high. In this review, we will discuss how the radiologist can add value to the referring physician by employing novel imaging techniques in the pre-operative evaluation as well as how the information can be conveyed in the most meaningful manner through the use of structured reporting. We will also familiarize the radiologist with the imaging appearance of common complications that occur after pancreatic surgery.


Subject(s)
Adenocarcinoma/diagnosis , Magnetic Resonance Imaging , Pancreas/diagnostic imaging , Pancreas/pathology , Pancreatic Neoplasms/diagnosis , Tomography, X-Ray Computed , Contrast Media , Humans , Radiographic Image Enhancement , Pancreatic Neoplasms
12.
Abdom Imaging ; 40(8): 3257-64, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26329977

ABSTRACT

OBJECTIVE: The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. MATERIALS AND METHODS: An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. RESULTS: Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. CONCLUSIONS: Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.


Subject(s)
Abdomen/surgery , Air , Drainage , Radiography, Interventional , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Catheters , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
13.
Radiology ; 275(2): 332-42, 2015 May.
Article in English | MEDLINE | ID: mdl-25906301

ABSTRACT

This is a review of small-bowel obstruction written primarily for residents. The review focuses on radiography and computed tomography (CT) for diagnosing small-bowel obstruction and CT for determining complications. (©) RSNA, 2015.


Subject(s)
Intestinal Obstruction/diagnostic imaging , Intestine, Small , Tomography, X-Ray Computed , Decision Trees , Humans , Intestinal Obstruction/complications , Intestinal Obstruction/etiology , Intestine, Small/blood supply , Ischemia/complications , Ischemia/diagnostic imaging , Tomography, X-Ray Computed/methods
14.
AJR Am J Roentgenol ; 204(6): W640-7, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25730444

ABSTRACT

OBJECTIVE: The purpose of this article is to provide the reader with a comprehensive overview of dual-energy MDCT applications for imaging renal masses. CONCLUSION: Dual-energy MDCT has the potential to substantially improve the ability of radiologists to diagnose renal masses compared with conventional MDCT, potentially streamlining patients' clinical management.


Subject(s)
Kidney Diseases/diagnostic imaging , Kidney/diagnostic imaging , Multidetector Computed Tomography/methods , Radiographic Image Enhancement/methods , Radiography, Dual-Energy Scanned Projection/methods , Adult , Diagnosis, Differential , Female , Humans , Male , Middle Aged
15.
Radiology ; 272(3): 767-76, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24844472

ABSTRACT

PURPOSE: To investigate whether dual-energy multi-detector row computed tomography (CT) with virtual monochromatic imaging can overcome renal cyst pseudoenhancement in a phantom experiment and a clinical study. MATERIALS AND METHODS: This retrospective single-center HIPAA-compliant study was approved by the institutional review board, with waiver of informed consent. Four renal compartments inserted into torso phantoms were filled with saline to simulate the unenhanced state and with iodinated solutions to simulate the three levels of renal parenchyma enhancement (140, 180, and 240 HU). Saline-filled spheres simulating renal cysts (15 and 18 mm in diameter) were serially suspended in the renal compartments and imaged with dual-energy and single-energy multi-detector row CT at four different energy levels (80, 100, 120, and 140 kVp). In addition, 28 patients (mean age, 66 years ± 10; mean body mass index, 31.3 kg/m(2) ± 6.2) with 34 intrarenal cysts were included. Virtual monochromatic images were reconstructed in 10-keV increments at energy levels ranging from 40 to 140 keV. Phantom and clinical data were analyzed by using multivariate regression analysis. RESULTS: In the phantom experiment, all polychromatic image data sets showed pseudoenhancement (postcontrast attenuation increase >10 HU) in all investigated conditions, with a significant effect on cyst size (P <.001), location (P <.001), and renal background attenuation level (P <.001). Virtual monochromatic images at energy levels ranging from 80 to 140 keV did not show pseudoenhancement, with the minimum attenuation increase (mean, 6.1 HU ± 1.6; range, 1.6-7.7 HU) on 80-keV images. In patients, pseudoenhancement never occurred on virtual monochromatic images at energy levels ranging from 90 to 140 keV. Patient body size had a significant effect (P = .007) on selection of the optimal monochromatic energy level. CONCLUSION: Dual-energy multi-detector row CT with reconstruction of virtual monochromatic images at an optimal energy level can overcome renal cyst pseudoenhancement.


Subject(s)
Algorithms , Kidney Diseases, Cystic/diagnostic imaging , Multidetector Computed Tomography/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Adult , Aged , Aged, 80 and over , Computer Simulation , Female , Humans , Male , Middle Aged , Models, Theoretical , Multidetector Computed Tomography/instrumentation , Phantoms, Imaging , Radiography, Dual-Energy Scanned Projection/instrumentation , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
16.
Radiology ; 270(2): 535-47, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24126364

ABSTRACT

PURPOSE: To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. RESULTS: For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. CONCLUSION: It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice.


Subject(s)
Multidetector Computed Tomography/methods , Radiation Dosage , Adolescent , Child , Child, Preschool , Female , Humans , Imaging, Three-Dimensional , Infant , Infant, Newborn , Male , Monte Carlo Method , Radiography, Abdominal , Radiography, Thoracic , Retrospective Studies
17.
Phys Med Biol ; 58(24): 8755-68, 2013 Dec 21.
Article in English | MEDLINE | ID: mdl-24301136

ABSTRACT

Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.


Subject(s)
Abdomen/anatomy & histology , Models, Anatomic , Pelvis/anatomy & histology , Pelvis/diagnostic imaging , Radiation Dosage , Radiography, Abdominal , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Body Mass Index , Child , Child, Preschool , Feasibility Studies , Female , Humans , Infant , Infant, Newborn , Male , Middle Aged , Young Adult
18.
AJR Am J Roentgenol ; 201(6): W867-76, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24261394

ABSTRACT

OBJECTIVE: This article will review the multimodality imaging spectrum of medullary thyroid carcinoma (MTC) with an emphasis on anatomic and functional imaging. Recent advances in the molecular cytogenetics of this tumor and the impact on diagnosis, prognosis, and development of novel targeted therapy will be discussed. CONCLUSION: MTC is a neuroendocrine tumor with unique clinicopathologic and radiologic features compared with other thyroid malignancies. Imaging plays an important role in the optimal management of this malignancy.


Subject(s)
Carcinoma, Medullary/diagnosis , Diagnostic Imaging , Thyroid Neoplasms/diagnosis , Biomarkers, Tumor/analysis , Carcinoma, Medullary/therapy , Diagnosis, Differential , Humans , Prognosis , Thyroid Neoplasms/therapy
19.
AJR Am J Roentgenol ; 201(5): W712-9, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24147501

ABSTRACT

OBJECTIVE: This article reviews the CT and MRI patterns of primary and secondary renal lymphomas and discusses the role of percutaneous biopsy in diagnosis and management. CONCLUSION: Renal lymphoma has a variable imaging spectrum and may mimic renal cell carcinoma. An awareness of the typical and atypical imaging features of both primary and secondary renal lymphomas can help the radiologist to suggest these diagnoses and recommend biopsy when appropriate.


Subject(s)
Kidney Neoplasms/diagnosis , Lymphoma/diagnosis , Magnetic Resonance Imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Diagnosis, Differential , Humans , Image Interpretation, Computer-Assisted , Kidney Neoplasms/diagnostic imaging , Lymphoma/diagnostic imaging , Multimodal Imaging
20.
AJR Am J Roentgenol ; 201(3): 651-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23971460

ABSTRACT

OBJECTIVE: The purpose of this study was to compare CT with conventional and simulated reduced-tube current in the evaluation for acute appendicitis in children. MATERIALS AND METHODS: Validated noise-addition (tube current-reduction) software was used to create 50% and 75% tube current reductions in 60 CT examinations performed for suspected appendicitis, resulting in 180 image sets. Three blinded pediatric radiologists scored the randomized studies for the following factors: presence of the normal appendix or appendicitis (5-point scale; 1=definitely absent and 5=definitely present), presence of alternate diagnoses, and overall image quality (1=nondiagnostic and 5=excellent). Truth was defined by the interpretation of the conventional examination. RESULTS: For conventional examinations, the total number of reviews (60 cases×3 readers=180) in which the normal appendix was identified was 120 of 180 (66.7%), compared with 108 of 180 (60%) in the 50% (p=0.19) and 91 of 180 (50.6%) in the 75% (p=0.002) tube current-reduction groups. Appendicitis was identified in a total of 39 of 180 (21.7%), 38 of 180 (21.1%), and 37 of 180 (20.6%) examinations, respectively (p>0.05). This translates to sensitivities of 97% and 95% for the 50% and 75% tube current-reduction groups, respectively. Alternate diagnoses were detected in 14%, 16%, and 13% of scans, respectively. Compared with conventional-tube current examinations, reader confidence and assessment of image quality were significantly decreased for both tube current-reduction groups. CONCLUSION: Simulated tube current-reduction technology provides for systematic evaluation of diagnostic thresholds. Application of this technology in the setting of suspected appendicitis shows that tube current can be reduced by at least 50% without significantly affecting diagnostic quality, despite a decrease in reader confidence and assessment of image quality.


Subject(s)
Appendicitis/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Child , Child, Preschool , Diagnosis, Differential , Female , Humans , Male , Radiation Dosage , Randomized Controlled Trials as Topic , Retrospective Studies , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...