Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
1.
Gastroenterology ; 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38582271

ABSTRACT

BACKGROUND & AIMS: High-dose proton pump inhibitor (PPI) therapy has been recommended to prevent rebleeding of high-risk peptic ulcer (PU) after hemostasis. Vonoprazan has been proven to be noninferior to PPIs in various acid-related diseases. This study aimed to compare the efficacy of vonoprazan vs PPI for preventing high-risk PU rebleeding after hemostasis. METHODS: A multicenter, randomized, noninferiority study was conducted in 6 centers. Pre-endoscopic and endoscopic therapy were performed according to standard protocol. After successful hemostasis, patients with high-risk PU bleeding (Forrest class Ia/Ib, IIa/IIb) were randomized into 1:1 to receive vonoprazan (20 mg twice a day for 3 days, then 20 mg once a day for 28 days) or high-dose PPI (pantoprazole intravenous infusion 8 mg/h for 3 days, then omeprazole 20 mg twice a day for 28 days). The primary outcome was a 30-day rebleeding rate. Secondary outcomes included 3- and 7-day rebleeding rate, all-cause and bleeding-related mortality, rate of rescue therapy, blood transfusion, length of hospital stay, and safety. RESULTS: Of 194 patients, baseline characteristics, severity of bleeding, and stage of ulcers were comparable between the 2 groups. The 30-day rebleeding rates in vonoprazan and PPI groups were 7.1% (7 of 98) and 10.4% (10 of 96), respectively; noninferiority (within 10% margin) of vonoprazan to PPI was confirmed (%risk difference, -3.3; 95% confidence interval, -11.2 to 4.7; P < .001). The 3-day and 7-day rebleeding rates in the vonoprazan group remained noninferior to PPI (P < .001 by Farrington and Manning test). All secondary outcomes were also comparable between the 2 groups. CONCLUSION: In patients with high-risk PU bleeding, the efficacy of vonoprazan in preventing 30-day rebleeding was noninferior to intravenous PPI. (ClinicalTrials.gov, Number: NCT05005910).

2.
Dig Endosc ; 2024 Mar 03.
Article in English | MEDLINE | ID: mdl-38433315

ABSTRACT

OBJECTIVES: This consensus was developed by the Asian EUS Group (AEG), who aimed to formulate a set of practice guidelines addressing various aspects of endoscopic ultrasound-guided tissue acquisition (EUS-TA). METHODS: The AEG initiated the development of consensus statements and formed an expert panel comprising surgeons, gastroenterologists, and pathologists. Three online consensus meetings were conducted to consolidate the statements and votes. The statements were presented and discussed in the first two consensus meetings and revised according to comments. Final voting was conducted at a third consensus meeting. The Grading of Recommendations, Assessment, Development, and Evaluation system was adopted to define the strength of the recommendations and quality of evidence. RESULTS: A total of 20 clinical questions and statements regarding EUS-TA were formulated. The committee recommended that fine-needle biopsy (FNB) needles be preferred over conventional fine-needle aspiration (FNA) needles for EUS-TA of subepithelial lesions. For solid pancreatic masses, rapid on-site evaluation is not routinely recommended when FNB needles are used. For dedicated FNB needles, fork-tip and Franseen-tip needles have essentially equivalent performance. CONCLUSION: This consensus provides guidance for EUS-TA, thereby enhancing the quality of EUS-TA.

3.
Endosc Int Open ; 12(1): E68-E77, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38193007

ABSTRACT

Background and study aims Adequacy of endoscope disinfection in resource-limited settings is unknown. Adenosine triphosphate (ATP) testing is useful for evaluation of endoscope reprocessing, and ATP <200 relative light units (RLUs) after manual endoscope cleaning has been associated with adequacy of endoscope disinfection. Methods Consecutive endoscopes undergoing reprocessing at five World Gastroenterology Organisation (WGO) training centers underwent ATP testing before and after an on-site educational intervention designed to optimize reprocessing practices. Results A total of 343 reprocessing cycles of 65 endoscopes were studied. Mean endoscope age was 5.3 years (range 1-13 years). Educational interventions, based on direct observation of endoscope reprocessing practices at each site, included refinements in pre-cleaning, manual cleaning, high-level disinfection, and endoscope drying and storage. The percentage of reprocessing cycles with post-manual cleaning ATP ≧200 decreased from 21.4% prior to educational intervention to 14.8% post-intervention ( P =0.11). In multivariable logistic modelling, gastroscopes were significantly less likely (odds ratio [OR] 0.04, 95% confidence interval [CI] 0.01-0.19; P <0.001) than colonoscopes to achieve post-manual cleaning ATP < 200. No other factor (educational intervention, study site, endoscope age) was significantly associated with improved outcomes. Endoscope ID was not significantly associated with ATP values, and sites that performed manual versus automated HLD did not have significantly different likelihood of post-manual cleaning ATP <200 (OR 1.18, 95% CI 0.56-2.50; P =0.67). Conclusions In resource-limited settings, approximately 20% of endoscope reprocessing cycles may result in inadequate disinfection. This was not significantly improved by a comprehensive educational intervention. Alternative approaches to endoscope reprocessing are needed.

5.
Endosc Ultrasound ; 12(1): 96-103, 2023.
Article in English | MEDLINE | ID: mdl-36861508

ABSTRACT

Background and Objectives: EUS-guided biliary drainage (EUS-BD) required a dedicated training. We developed and evaluated a nonfluoroscopic, all-artificial training model known as Thai Association for Gastrointestinal Endoscopy Model 2 (TAGE-2) for the training of EUS-guided hepaticogastrostomy (EUS-HGS) and EUS-guided choledochoduodenostomy (EUS-CDS). We hypothesize that trainers and trainees would appreciate the ease of the nonfluoroscopy model and increase their confidence to start their real procedures in humans. Materials and Methods: We prospectively evaluated the TAGE-2 launched in two international EUS hands-on workshops and have followed trainees for 3 years to see long-term outcomes. After completing the training procedure, the participants answered questionnaires to assess their immediate satisfaction of the models in and also the impact of these models on their clinical practice 3 years after the workshop. Results: A total of 28 participants used the EUS-HGS model and 45 participants used the EUS-CDS model. The EUS-HGS model was rated as excellent by 60% of beginners and 40% by experienced and the EUS-CDS model was rated as excellent by 62.5% of beginners and 57.2% of experienced. The majority of trainees (85.7%) have started the EUS-BD procedure in humans without additional training in other models. Conclusion: Our nonfluoroscopic, all-artificial model for EUS-BD training is convenient to be used with good-to-excellent satisfaction scored by the participants in most aspects. It can help the majority of trainees start their procedures in humans without additional training in other models.

6.
DEN Open ; 3(1): e213, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36843625

ABSTRACT

Background and aim: Endoscopic sleeve gastroplasty (ESG) is an effective treatment for obesity. Recently, a novel single-channel endoscopic suturing device has been made available to overcome the need for a double-channel endoscope. However, there is limited evidence evaluating its utility for ESG. In this multicenter study, we aim to assess the efficacy and safety of the single-channel suturing device for ESG. Methods: We reviewed the records of 18 patients who underwent ESG using the novel device at the Singapore General Hospital, Singapore, and Siriraj Hospital, Bangkok, between 2020-2021. We adopted a "U" suture pattern. Our primary outcome was to assess technical feasibility and safety. The secondary outcome was to determine the percentage of total body weight loss at 1 year. Results: The mean ± SD age and body mass index were 42 ± 8.5 years and 34.9 ± 4.4 kg/m2, respectively. The majority were female (61%). ESG was technically successful in 94% (n = 17) of patients. Device dislodgement occurred in one patient. We used an average of five sutures (range, 4-8), and the mean ± SD procedure time was 96.5 ± 43.8 min. No complications occurred. The mean ± SD length of stay was 2.3 ± 1.5 days. The mean ± SD percentage of total body weight loss at 6 and 12 months were 16 ± 5.2% and 13.1 ± 5.8%, respectively. We found that >5%, >10%, and >15% total body weight loss was observed in 83.3%, 72.2%, and 56%, respectively. Conclusion: ESG using the single-channel endoscopic suturing system is safe and effective for inducing weight loss at 1 year in patients with obesity.

7.
Clin Transl Gastroenterol ; 14(5): e00574, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36854054

ABSTRACT

INTRODUCTION: Cytomegalovirus (CMV) viral load detected by real-time polymerase chain reaction (PCR) in plasma or stool may facilitate detection of CMV colitis. METHODS: This prospective study enrolled 117 patients with clinically suspected CMV colitis. Patients presenting with gastrointestinal symptoms and having increased risk of CMV infection were eligible. All participants underwent colonoscopy with tissue biopsy. Five patients underwent colonoscopy twice because of clinical recurrence, resulting in a total of 122 colonoscopies. Stool CMV-PCR and plasma CMV-PCR were performed within 7 days before/after colonoscopy. Twenty asymptomatic volunteers also underwent the same protocol. RESULTS: Twenty-seven (23.1%) of 122 colonoscopies yielded positive for CMV colitis. The sensitivity and specificity was 70.4% and 91.6% for stool CMV-PCR and 66.7% and 94.7% for plasma CMV-PCR, respectively. The sensitivity of either positive plasma or positive stool CMV-PCR was 81.5%, which is significantly higher than that of plasma CMV-PCR alone ( P = 0.045). However, positive results from both tests yielded a specificity of 95.8%, which is significantly higher than that of stool CMV-PCR alone ( P = 0.045). There was a good and significant correlation between stool CMV-PCR and plasma CMV-PCR ( r = 0.71, P < 0.01), and both tests significantly correlated with the cytomegalic cell count ( r = 0.62, P < 0.01 for stool and r = 0.64, P < 0.01 for plasma). There were no positive stool or plasma CMV-PCR assays among volunteers. DISCUSSION: The results of this study strongly suggest that the combination of stool CMV-PCR and plasma CMV-PCR can be used to confidently rule in (both positive) or rule out (both negative) a diagnosis of CMV colitis.


Subject(s)
Colitis , Cytomegalovirus Infections , Humans , Cytomegalovirus/genetics , Real-Time Polymerase Chain Reaction , Prospective Studies , DNA, Viral/genetics , Cytomegalovirus Infections/diagnosis , Colitis/diagnosis
8.
Dig Endosc ; 35(4): 422-429, 2023 May.
Article in English | MEDLINE | ID: mdl-36749036

ABSTRACT

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost-effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer-aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health-care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe-related cancer prevention; Statement 1.4: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer-aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health-care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high-quality cost-effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health-care systems.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Humans , Artificial Intelligence , Colonoscopy , Endoscopy, Gastrointestinal , Diagnosis, Computer-Assisted , Colonic Polyps/diagnosis , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/prevention & control
9.
J Gastroenterol Hepatol ; 38(4): 584-589, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36582040

ABSTRACT

BACKGROUND AND AIM: Dedicated studies evaluating the impact of COVID-19 on outcomes of pancreatobiliary IgG4 related disease (IgG4-RD) patients are scarce. Whether COVID-19 infection or vaccination would trigger IgG4-RD exacerbation remains unknown. METHODS: Pancreatobiliary IgG4-RD patients ≥ 18 years old with active follow-up since January 2020 from nine referral centers in Asia, Europe, and North America were included in this multicenter retrospective study. Outcome measures include incidence and severity of COVID-19 infection, IgG4-RD disease activity and treatment status, interruption of indicated IgG4-RD treatment. Prospective data on COVID-19 vaccination status and new COVID-19 infection during the Omicron outbreak were also retrieved in the Hong Kong cohort. RESULTS: Of the 124 pancreatobiliary IgG4-RD patients, 25.0% had active IgG4-RD, 71.0% were on immunosuppressive therapies and 80.6% had ≥ 1 risk factor for severe COVID. In 2020 (pre-vaccination period), two patients (1.6%) had COVID-19 infection (one requiring ICU admission), and 7.2% of patients had interruptions in indicated immunosuppressive treatment for IgG4-RD. Despite a high vaccination rate (85.0%), COVID-19 infection rate has increased to 20.0% during Omicron outbreak in the Hong Kong cohort. A trend towards higher COVID-19 infection rate was noted in the non-fully vaccinated/unvaccinated group (17.6% vs 33.3%, P = 0.376). No IgG4-RD exacerbation following COVID-19 vaccination or infection was observed. CONCLUSION: While a low COVID-19 infection rate with no mortality was observed in pancreatobiliary IgG4-RD patients in the pre-vaccination period of COVID-19, infection rate has increased during the Omicron outbreak despite a high vaccination rate. No IgG4-RD exacerbation after COVID-19 infection or vaccination was observed.


Subject(s)
COVID-19 , Immunoglobulin G4-Related Disease , Humans , Adolescent , Retrospective Studies , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19 Vaccines , Prospective Studies , Immunoglobulin G , Vaccination , Hong Kong/epidemiology
10.
Medicine (Baltimore) ; 101(48): e31989, 2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36482571

ABSTRACT

In potential small bowel bleeding, video capsule endoscopy (VCE) is excellent to detect mucosal lesions, while mural-based lesions are better detected by computed tomography enterography (CTE). A predictive tool to identify mural-based lesions should guide selecting investigations. In this retrospective study, we developed and validated the "MURAL" model based on logistic regression to predicts bleeding from mural-based lesions. Cost-effectiveness analysis comparing diagnostic strategy among VCE, CTE, and MURAL model was performed. Of 296 patients, 196 and 100 patients were randomly included in the derivative and validation cohorts, respectively. The MURAL model comprises 5 parameters: age, presence of atherosclerosis, chronic kidney disease, antiplatelet use, and serum albumin level. The area under the receiver operating characteristic curve was 0.778 and 0.821 for the derivative and validation cohorts, respectively. At a cutoff value of 24.2%, the model identified mural-based lesions with 70% sensitivity and 83% specificity in the validation cohort. Cost-effectiveness analysis revealed that application of the MURAL model demonstrated a comparable missed lesion rate but had a lower missed tumor rate, and lower cost compared to VCE strategy. The model for predicting mural-based lesions provide some guidance in investigative decision-making, which may improve diagnostic efficiency and reduce costs.


Subject(s)
Hemorrhage , Intestines , Humans , Retrospective Studies
11.
J Clin Transl Hepatol ; 10(6): 1229-1239, 2022 Dec 28.
Article in English | MEDLINE | ID: mdl-36381092

ABSTRACT

Currently, scientific interest has focused on fat accumulation outside of subcutaneous adipose tissue. As various imaging modalities are available to quantify fat accumulation in particular organs, fatty pancreas has become an important area of research over the last decade. The pancreas has an essential role in regulating glucose metabolism and insulin secretion by responding to changes in nutrients under various metabolic circumstances. Mounting evidence has revealed that fatty pancreas is linked to impaired ß-cell function and affects insulin secretion with metabolic consequences of impaired glucose metabolism, type 2 diabetes, and metabolic syndrome. It has been shown that there is a connection between fatty pancreas and the presence and severity of nonalcoholic fatty liver disease (NAFLD), which has become the predominant cause of chronic liver disease worldwide. Therefore, it is necessary to better understand the pathogenic mechanisms of fat accumulation in the pancreas and its relationship with NAFLD. This review summarizes the epidemiology, diagnosis, risk factors, and metabolic consequences of fatty pancreas and discusses its pathophysiology links to NAFLD.

12.
Front Oncol ; 12: 922386, 2022.
Article in English | MEDLINE | ID: mdl-36147905

ABSTRACT

Background: Palliative endobiliary drainage is the mainstay treatment for unresectable malignant biliary obstruction (MBO). Despite optimal drainage, the survival benefit is arguable. This study aimed to identify factors predicting post-endoscopic drainage mortality and develop and validate a mortality prediction model. Methods: We retrospectively analyzed data for 451 patients with unresectable pancreatobiliary cancers undergoing first endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary stent placement between 2007 and 2017. We randomly assigned patients in a 3:1 fashion into a derivation cohort (n=339) and validation cohort (n=112). Predictors for 90-day mortality post-stenting were identified from the derivation cohort. A prediction model was subsequently developed and verified with the validation cohort. Results: The overall 90-day mortality rate of the derivation cohort was 46.9%, and the mean age was 64.2 years. The 2 most common diagnoses were cholangiocarcinoma (53.4%) and pancreatic cancer (35.4%). In all, 34.2% had liver metastasis. The median total bilirubin (TB) level was 19.2 mg/dL, and the mean serum albumin was 3.2 g/dL. A metallic stent was used for 64.6% of the patients, and the median stent patency time was 63 days. A total of 70.8% had TB improvement of more than 50% within 2 weeks after stenting, and 14.5% were eligible for chemotherapy. Intrahepatic obstruction (OR=5.69; P=0.023), stage IV cancer (OR=3.01; P=0.001), pre-endoscopic serum albumin (OR=0.48; P=0.001), TB improvement within 2 weeks after stenting (OR=0.57; P=0.036), and chemotherapy after ERCP (OR=0.11; P<0.001) were associated with 90-day mortality after stenting. The prediction model was developed to identify the risk of death within 90 days post-stent placement. The AUROC was 0.76 and 0.75 in derivation and validation cohorts. Patients with a score ≥ 1.40 had a high likelihood of death, whereas those scoring < -1.50 had a low likelihood of death. Additionally, a score ≥ 0.58 provided a 75.2% probability of death, which highlights the usability of the model. Conclusions: This study proposes a useful validated prediction model to forecast the 90-day mortality of unresectable MBO patients after stenting. The model permits physicians to stratify the death risk and may be helpful to provide a proper palliative strategy.

13.
PLoS One ; 17(8): e0272918, 2022.
Article in English | MEDLINE | ID: mdl-35984773

ABSTRACT

BACKGROUND: Endoscopic drainage is the primary treatment for unresectable malignant biliary obstruction (MBO). This study developed and validated a pre-endoscopic predictive score for clinical success after stent placement. METHODS: Patients with unresectable MBO undergoing ERCP-guided endobiliary stent placement between 2007 and 2017 were randomly divided into derivation (n = 383) and validation (n = 128) cohorts. To develop the risk score, clinical parameters were built by logistic regression to predict (1) ≥ 50% total bilirubin (TB) resolution within 2 weeks and (2) bilirubin normalization (TB level <1.2 mg/dL) within 6 weeks following stenting. The scoring scheme was applied to the validation cohort to test its performance. RESULTS: A ≥ 50% TB resolution within 2 weeks was shown in 70.5% of cases. The risk scoring scheme had areas under the receiver operating characteristic curve (AUROC) of 0.70 (95% CI, 0.64-0.76) and 0.67 (95% CI, 0.57-0.77) in the derivation and validation cohorts, respectively. Thirty-one percent had TB normalization within 6 weeks after stenting. Significant predictors for TB normalization were extrahepatic biliary obstruction (odds ratio [OR] = 2.35), pre-endoscopic TB level (OR = 0.88), and stent type (OR = 0.42). The AUROC of a risk score for predicting TB normalization within 6 weeks was 0.78 (95% CI, 0.72-0.83) and 0.76 (95% CI, 0.67-0.86) in the derivation and validation cohorts, respectively. A score > 1.30 yielded a specificity of 98% and a positive predictive value of 84% for predicting TB normalization. A score of < -4.18 provided a sensitivity of 80%-90% and a negative predictive value of 90%-93% for predicting the absence of TB normalization. CONCLUSIONS: The pre-endoscopic scoring system comprising biliary obstruction level, liver biochemistry, and type of stent provides prediction indices for TB normalization within 6 weeks after stenting. This scheme may help endoscopists identify patients with unresectable MBO suited for palliative stenting.


Subject(s)
Cholestasis, Extrahepatic , Cholestasis , Neoplasms , Bilirubin , Cholestasis/etiology , Cholestasis/surgery , Drainage , Humans , Risk Factors , Stents
15.
Endosc Ultrasound ; 11(3): 201-207, 2022.
Article in English | MEDLINE | ID: mdl-35708369

ABSTRACT

Bckground and Objectives: EUS-guided cystogastrostomy is a well-established advanced endoscopic technique with a steep-learning curve which necessitates an ex-vivo simulator that would allow for adequate training. The aim of this study is to evaluate the feasibility of the model in allowing training for EUS-guided cystogastrostomy using lumen-apposing metal stent (LAMS). Subjects and Methods: The model was created by ROEYA Training Center, Egypt, using native porcine tissue to create fluid collections simulating both cystic and solid lesions. It was designed and tested in advance while the hydrogel was added on-site. The simulator was evaluated prospectively in five training sessions involving 17 international experts. The task was to successfully deploy the LAMS to drain the created cyst. After using the simulator, the experts were asked to fill a questionnaire to assess their experience. The primary endpoint was overall satisfaction with the model as a training tool. Results: All of the experts were satisfied with the model as a tool to train endoscopists for the technique. 76.5% (n = 11) of the experts thought the model to be moderately realistic. Proper visualization was reported by 94.1% of the experts. All experts believed the lesions to be either slightly like or very similar to real lesions. The model was graded "easy" in difficulty by 11 of the experts. Conclusions: In all parameters assessed, the experts thought the model to be a useful tool for future training. This preliminary study suggests that the aforementioned simulator can be used to train endoscopists on using LAMS in a risk-free environment.

16.
Front Med (Lausanne) ; 9: 847361, 2022.
Article in English | MEDLINE | ID: mdl-35572969

ABSTRACT

Background: Colorectal cancer (CRC) screening uptake is generally low in the Asia Pacific and physicians' recommendations affect the screening participation. Objective: The study aimed to assess Thai physicians' recommendations for CRC screening, and the awareness of and adherence to international guidelines. Methods: A survey containing questions assessing physicians' demographic data, screening recommendations, and awareness of the international CRC screening guidelines assessed by clinical vignettes. Independent predictors of physicians' recommendations for CRC screening were determined by logistic regression analysis. Results: Five hundred and eighty-sixth of 1,286 (46%) physicians completed the survey, and 58% of them offered CRC screening. The majority of colorectal surgeons (91%) and gastroenterologists (86%) endorsed screening, whereas 35% of primary care physicians recommended screening. The patient's age was the only factor influencing the physician's decision to offer CRC screening (OR, 2.75: 95% CI, 1.61-4.67). Colonoscopy was the most recommended modality among specialists, whereas 60% of primary care physicians offered fecal occult blood tests (FOBTs). The guidelines awareness was noted in 81% of participants, with the highest rates among gastroenterologists and colorectal surgeons. Gastroenterologists were more likely to adhere to the guidelines than surgeons, but both recommended shorter interval surveillance colonoscopy than guidelines recommendations in cases of small hyperplastic rectosigmoid polyps. Conclusions: Recommendations for CRC screening and awareness of guidelines vary among different specialties. A low proportion of primary care physicians recommended screening and colorectal surgeons and gastroenterologists recommended shorter intervals for surveillance of small hyperplastic polyp than suggested by guidelines.

17.
J Clin Med ; 11(9)2022 Apr 27.
Article in English | MEDLINE | ID: mdl-35566587

ABSTRACT

This study aims to investigate the effects of COVID-19 on clinical outcomes of non-COVID-19 patients hospitalized for upper gastrointestinal bleeding (UGIB) during the pandemic. A retrospective review is conducted. We recruited patients with UGIB admitted during the pandemic's first wave (April 2020 to June 2020), and the year before the pandemic. The outcomes between the two groups were compared using propensity score matching (PSM). In total, 60 patients (pandemic group) and 460 patients (prepandemic group) are included. Patients admitted during the pandemic (mean age of 67 ± 14 years) had a mean Glasgow−Blatchford score of 10.8 ± 3.9. They were older (p = 0.045) with more underlying malignancies (p = 0.028), had less history of NSAID use (p = 0.010), had a lower platelet count (p = 0.007), and had lower serum albumin levels (p = 0.047) compared to those admitted before the pandemic. Esophagogastroduodenoscopy (EGD) was performed less frequently during the pandemic (43.3% vs. 95.4%, p < 0.001). Furthermore, the procedure was less likely to be performed within 24 h after admission (p < 0.001). After PSM, admissions during the pandemic were significantly associated with decreased chances of receiving an endoscopy (adjusted odds Ratio (OR), 0.02; 95% CI, 0.003−0.06, p < 0.001) and longer hospital stay (adjusted OR, 2.17; 95% CI, 1.13−3.20, p < 0.001). Additionally, there was a slight increase in 30-day mortality without statistical significance (adjusted OR, 1.92; 95% CI, 0.71−5.19, p = 0.199) and a marginally higher rebleeding rate (adjusted OR, 1.34; 95% CI, 0.44−4.03, p = 0.605). During the pandemic, the number of EGDs performed in non-COVID-19 patients with UGIB decreased with a subsequent prolonged hospitalization and potentially increased 30-day mortality and rebleeding rate.

18.
PLoS One ; 17(3): e0263982, 2022.
Article in English | MEDLINE | ID: mdl-35320282

ABSTRACT

BACKGROUND/AIM: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the primary method for tissue acquisition of intra-abdominal masses. However, the main limitation of cytology alone is the lack of tissue architecture and inadequate samples. This study aimed to evaluate the diagnostic performance of combined conventional cytology and cell block preparation obtained from EUS-FNA of intra-abdominal masses without Rapid On-site Evaluation (ROSE). METHODS: Cytologic smears and cell block slides of 166 patients undergoing EUS-FNA during 2010-2015 were reviewed by an experienced cytopathologist blinded to clinical data. RESULTS: 125 patients had neoplastic lesions. Pancreatic adenocarcinoma was the most common etiology (35.5%), followed by lymph node metastasis (27.7%). The mean mass size was 2.5±1.3 cm. The mean number of passes was 1.9±1.28. Tissue adequacy for conventional cytology and cell block preparation was 78.9% and 78.1%, respectively. Factors associated with tissue adequacy were assessed. For cytology, lesions of > 2.1 cm, masses in the pancreatic body or tail, malignancy, and pancreatic cancer were positively associated with adequate cellularity. For cell block preparation, lesions of > 3 cm and malignancy were associated with increased tissue adequacy. The conventional cytology alone had a sensitivity of 68.5%, a specificity of 95.7%, and an area under the receiver operating characteristics (AUROC) of 0.821. The cell block preparation alone had a sensitivity of 65.4%, a specificity of 96%, and an AUROC of 0.807. The combined conventional cytology and cell block preparation performed significantly better than either method alone (p<0.05), as demonstrated by an increased AUROC of 0.853. Furthermore, cell block detected malignancy in 9.3% of cases where the cytologic smears failed to identify malignant cells. CONCLUSIONS: The combined conventional cytology and cell block preparation increased the diagnostic accuracy of EUS-FNA compared to either method alone. This approach should be implemented in routine practice, especially where ROSE is unavailable.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Adenocarcinoma/pathology , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Humans , Pancreas/diagnostic imaging , Pancreas/pathology , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Retrospective Studies , Sensitivity and Specificity , Pancreatic Neoplasms
19.
J Clin Med ; 11(4)2022 Feb 17.
Article in English | MEDLINE | ID: mdl-35207324

ABSTRACT

BACKGROUND: The impact of rapid on-site cytologic evaluation (ROSE) on endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is widely debated. This study aims to assess the diagnostic performance of EUS-FNB in the absence of ROSE in abdominal masses. METHODS: Patients with abdominal masses undergoing EUS-FNB using 22-gauge Franseen needles and the slow-pull technique were prospectively enrolled in this study. Macroscopic on-site evaluation (MOSE) was performed without ROSE. RESULTS: 100 patients were recruited between 2018 and 2020. Seventy-eight patients had neoplasms, and twenty-two patients had benign diseases. Common diagnoses included pancreatic cancer (n = 27), mesenchymal tumors (n = 17), and metastatic tumors (n = 14). The mean mass size was 3.9 ± 2.6 cm. The median pass number was three. Eighty-nine percent had adequate specimens for histologic evaluation. Malignancy increased the odds of obtaining adequate tissue (OR 5.53, 95% CI, 1.36-22.5). For pancreatic cancer, FNB had a sensitivity of 92.3%, a specificity of 100%, a positive predictive value (PPV) of 100%, a negative predictive value (NPV) of 97%, and an AUROC of 0.96. The sensitivity, specificity, PPV, NPV, and AUROC for mesenchymal cell tumors were 100%, 95.9%, 84.2%, 100%, and 0.98, respectively. For metastatic tumors, FNB was 100% sensitive and specific, with an AUROC of 1.00. There were no procedure-related complications. CONCLUSIONS: 22-gauge Franseen needles with the slow-pull technique and MOSE without ROSE provide excellent diagnostic performances for malignant lesions. Thus, MOSE should be implemented in real-world practice, and ROSE can be obviated when EUS-FNB is employed.

20.
Clin Endosc ; 55(2): 279-286, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34974679

ABSTRACT

BACKGROUND/AIMS: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a standard procedure for obtaining tissue from lesions near the gastrointestinal lumen. However, there is a scarcity of information on the diagnostic performance of EUS-FNA for abdominal lymphadenopathy of unknown causes. To assess the accuracy of EUS-FNA in diagnosing abdominal lymphadenopathy of unknown etiology. METHODS: The EUS records of patients with undiagnosed abdominal lymphadenopathy between 2010 and 2015 were reviewed. RESULTS: A total of 42 patients were included in this study. Adequate specimens were obtained from 40 patients (95%). The final diagnoses were metastatic cancer (n=16), lymphoma (n=9), tuberculosis (n=8), inflammatory changes (n=6), and amyloidosis (n=1). For diagnosing malignancy, EUS-FNA had a sensitivity of 84.6%, specificity of 95.7%, positive predictive value of 91.7%, negative predictive value of 91.7%, and area under the receiver operating characteristic curve (AUROC) of 0.901. For the diagnosis of lymphoma, EUS-FNA was 100% accurate when combined with cytologic evaluation and immunohistochemical staining. The diagnostic sensitivity decreased to 75%, whereas the specificity remained 100%, for tuberculosis. The overall AUROC was 0.850. No procedure-related complications occurred. CONCLUSION: EUS-FNA showed high diagnostic performance for abdominal lymphadenopathy of unknown causes, especially malignancy, lymphoma, and tuberculosis. Therefore, it is a crucial diagnostic tool for this patient population.

SELECTION OF CITATIONS
SEARCH DETAIL
...