Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Neuroradiology ; 56(2): 117-27, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24337610

ABSTRACT

INTRODUCTION: Indices of collateral flow deficit derived from MR perfusion imaging that are predictive of MCA-M1 recanalization after intravenous thrombolysis have been recently reported. Our objective was to test the performance of such MRI-derived collateral flow indices for prediction of recanalization after endovascular thrombectomy. METHODS: Fifty-seven patients with MCA-M1 occlusion evaluated with multimodal MRI prior to thrombectomy were included. Bayesian processing allowed quantification of collateral perfusion indices like the volume of tissue with severely prolonged arterial-tissue delay (>6 s) (VolATD6). Baseline DWI lesion volume was also measured. Correlations with angiographic collateral flow grading and post-thrombectomy recanalization were assessed. RESULTS: VolATD6 < 27 ml or DWI lesion volume <15 ml provide the most accurate diagnosis of excellent collateral supply (p < 0.0001). The combination of VolATD6 > 27 ml and DWI lesion volume >15 ml significantly discriminates recanalizers versus nonrecanalizers (whole cohort, p = 0.032; MERCI cohort (n = 50), p = 0.024). When both criteria are positive, 76.2 % of the patients treated with the MERCI retriever do not fully recanalize (p = 0.024). In multivariate analysis, the aforementioned combined criterion and the angiographic collateral grade are the only independent predictors of recanalization with the MERCI retriever (p = 0.015 and 0.029, respectively). CONCLUSION: Bayesian arterial-tissue delay maps and DWI maps provide a non-invasive assessment of the degree of collateral flow and a combined index that is predictive of MCA-M1 recanalization after endovascular thrombectomy. Further studies are needed to evaluate the accuracy of this index in patients treated with novel stent retriever devices.


Subject(s)
Cerebral Revascularization/methods , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Infarction, Middle Cerebral Artery/diagnosis , Infarction, Middle Cerebral Artery/surgery , Magnetic Resonance Angiography/methods , Thrombectomy/methods , Aged , Female , Humans , Imaging, Three-Dimensional/methods , Male , Multimodal Imaging/methods , Prognosis , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...