Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
Add more filters










Publication year range
1.
Braz. dent. sci ; 17(2): 63-69, 2014. ilus, tab
Article in English | LILACS, BBO - Dentistry | ID: lil-728127

ABSTRACT

Objective: To evaluate the visual perception of dentistry professors, technicians and undergraduates on tooth color selection through varying the background contrast and tooth translucency. Material & Methods: Fifteen artificial teeth of different colors and translucencies were used and divided into three groups and placed onto cardboards in the following colors: white, red and black. Blindly, the observers (professors (n = 30), technicians (n = 30) and undergraduates (n = 30), selected the artificial tooth color that they judged compatible with VITA scale, when positioned onto the three background colors, at constant illumination through white artificial light. The obtained data were statistically analyzed by Kruskal-Wallis test. Results: There were no statistically significant differences among the studied populations in tooth color selection, regardless of the background colors, with all observers exhibiting a high number of errors. There were statistically significant differences in the number of matching answers among the studied teeth, with those exhibiting different translucencies showing the highest error rate (D1= 2 right answers; D4 = 0 right answers). Conclusion: Professional expertise was not decisive in tooth color selection; the number of matching answers of the three populations varied according to the background used; the most translucent teeth with different resin layers exhibited the smallest number of matching answers and the observers’ visual acuity differed and it should be effectively trained to achieve success in tooth color selection of prostheses and restorations


Objetivo: Avaliar a percepção visual na seleção de cor de dentes por professores de odontologia, técnicos de laboratório e alunos da graduação com contraste simultâneo de fundo. Material e Métodos: Foram utilizados 15 dentes de estoque de diferentes cores e translucidez, divididos em três grupos e posicionados em fundos de papel cartão nas cores: branco, vermelho e preto. Os observadores professores (n = 30), técnicos de laboratório (n = 30) e alunos (n = 30), selecionavam a cor dos dentes de estoque de diferentes cores, posicionados nas três cores de fundo, sempre com iluminação de luz artificial branca e comparavam com dentes da escala de cores. Após obtenção dos dados estes foram analisados pelo teste estatístico de Kruskal- Wallis. Resultados: os resultados mostraram que não existem diferenças estatisticamente significantes entre as populações estudadas, quando da seleção da cor dos dentes, independentemente das cores dos fundos e que o número de acertos foi muito pequeno, necessitando de melhor aprimoramento dos profissionais e alunos de graduação. Conclusão: Não houve diferença nos valores de acerto dos professores, alunos e técnicos de laboratório; a distribuição de acertos nos três diferentes fundos foi semelhante para os observadores; a porcentagem de erros entre os observadores foi muito elevada; a maior parte dos acertos diferiu conforme o dente avaliado, devido à maior translucidez e camadas de resina existentes e há necessidade de maior treinamento dos profissionais de odontologia para seleção das cores dos dentes.


Subject(s)
Spectrophotometers , Tooth, Artificial
2.
Gen Dent ; 60(3): e123-30, 2012.
Article in English | MEDLINE | ID: mdl-22623466

ABSTRACT

The aim of this study was to evaluate the effect of conventional and whitening dentifrices on the weight loss, surface roughness, and early in situ biofilm formation on the surface of dental ceramics. Standardized feldspar ceramic specimens (Vita VM7 and Vita VM13) were submitted to the following experimental conditions: no brushing; brushing without a dentifrice; brushing with a conventional dentifrice; and brushing with a whitening dentifrice. A brushing machine was used to simulate brushing. The mass and surface roughness of all specimens from the test groups were evaluated prior to and after brushing. Ten participants used an oral device for eight hours to evaluate the biofilm formed in situ on the specimens. Scanning electron microscopy was used for qualitative and quantitative analysis of the biofilm. ANOVA and Tukey tests were used to analyze the results of weight loss, surface roughness, and presence of bacteria. A one-way Kruskal-Wallis test was used for bacterial colonization results. For both ceramics, brushing with a whitening dentifrice resulted in weight loss that was significantly greater when compared to brushing without a dentifrice or with a conventional dentifrice. Increased surface roughness was noticed on VM13 ceramic samples with both dentifrices, whereas only conventional dentifrice had a significant effect on the surface roughness of VM7 samples. For both VM7 and VM13, no difference was found between the experimental conditions with regard to the presence or number of bacteria. Cocci and short rods were the predominant microbial morphotypes. Granular or fibrillar acellular material partially covered the specimens. Brushing with a whitening dentifrice resulted in significant weight loss of ceramic restorations, while brushing with both conventional and whitening dentifrices can roughen ceramic surfaces. The increase in roughness was not clinically significant to contribute to increased biofilm formation.


Subject(s)
Biofilms/growth & development , Ceramics/chemistry , Dental Materials/chemistry , Dentifrices/therapeutic use , Tooth Bleaching Agents/therapeutic use , Toothbrushing/methods , Aluminum Silicates/chemistry , Dental Porcelain/chemistry , Humans , Materials Testing , Microscopy, Electron, Scanning , Potassium Compounds/chemistry , Surface Properties , Time Factors , Toothbrushing/instrumentation
3.
J Prosthodont ; 21(2): 94-100, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22050205

ABSTRACT

PURPOSE: The aim of this study was to evaluate the marginal discrepancy (MD) and internal discrepancy (ID) of ceramic crowns manufactured by a CAD/CAM system, having different finish lines. The hypotheses tested were that the finish line type would not influence the MD or ID of the crowns, and ID would not change in different regions. MATERIALS AND METHODS: Three aluminum master dies (height: 5.5 mm, Ø: 7.5 mm, conicity: 6°) with different finish lines (TC: tilted chamfer; LC: large chamfer; RS: rounded shoulder) were manufactured. Ten impressions were made from each master die using a modified parallelometer. Impressions were poured in type IV dental stone, and 30 ceramic crowns (IPS Empress CAD, Ivoclar) were subsequently milled. The crowns were fixed on their respective metallic die using a metallic fixation device. The distance between the external edges of the crown to the edge of the cervical preparation was performed at 50 points on the respective metallic die (MD analysis). With the replica technique, the ID values of each crown were further evaluated at 12 points equidistant to each other in three regions: radius (R), axial (A), and occlusal (Occl). The measurements were performed using an optical microscope (250×). The data (µm) were analyzed using ANOVA and Tukey's test (5%). RESULTS: The RS group (28.24 ± 11.42 µm) showed significantly lower MD values (p= 0.001) than those of TC (99.92 ± 18.32 µm) and LC (64.71 ± 25.64 µm) groups, both of which also differed statistically from one another. The ID results demonstrated significantly lower values in the LC group (183.01 ± 62.82 µm) (p= 0.0014) than those of TC (216.26 ± 83.23 µm) and RS (219.12 ± 87.24 µm) groups. ID results of TC and RS were not significantly different. Additionally, the ID results showed significant differences among the regions (p= 0.0001). The null hypotheses were rejected. CONCLUSION: The RS finish line produced MD values significantly lower than tilted and large chamfer, but large chamfer presented the lowest internal discrepancy values. Independent of the finish line type, internal discrepancy was the lowest in the axial region followed by radius and occlusal regions.


Subject(s)
Computer-Aided Design , Crowns , Dental Marginal Adaptation , Dental Porcelain , Dental Prosthesis Design , Analysis of Variance , Dental Impression Technique , Humans , Models, Dental , Prosthesis Fitting , Replica Techniques , Statistics, Nonparametric , Tooth Preparation, Prosthodontic
4.
Braz. dent. sci ; 14(1/2): 49-53, 2011. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-642712

ABSTRACT

O objetivo desse estudo é avaliar o efeito da desinfecção associada à escovação na rugosidade (Ra e Rz) superficial de resina acrílica termopolimerizável. Cinquenta cilindros de resina acrílica (Lucitone 550 Dentsply) de dimensões 0,5 mm x 0,5 mm foram confeccionados, utilizando-se o ciclo térmico curto de polimerização (73°C por 90 min, seguidos por imersão em água a 94°C durante 30 min), de acordo com as instruções do fabricante. Os espécimes termopolimerizados foram imersos em água destilada a 37 ±1°C por 48 horas e divididos em 5 grupos (n=10) de acordo com o método de desinfecção: GrControle- sem desinfecção e sem escovação; Gr1-água destilada seguido de escovação; Gr2- hipoclorito de Sódio 1% seguido de escovação; Gr3- gluconato de clorexidina 2% seguido de escovação, e G4- perborato de sódio a 3,78% seguido de escovação. Os grupos foram imersos por 5 min nas soluções correspondentes antes do ciclo de escovação (10.000 ciclos). Foram analisados em rugosímetro de contato os valores para Ra e Rz. Os resultados foram analisados estatisticamente pelo método ANOVA e as médias comparadas pelo teste de Tukey (α=0,05). As médias obtidas para o Ra e Rz respectivamente foram: Gr controle 0,16 (0,03) e 0,77 (0,21); Gr1 0,3 (0,13) e 1,25 (0,62); Gr2 0,24(0,09) e 1,02 (0,4); Gr3 0,34 (0,14) e 1,45(0,55); Gr4 0,38(0,14) e 1,7(0,65). O teste ANOVA revelou que a rugosidade para os dois parâmetros foi significativamente afetada pela abrasão provocada pela escovação com dentifrício (PRa=0,0009; PRz=0,0021). Pode-se concluir que a escovação associada à desinfecção com hipoclorito de sódio produziu menor efeito sobre a rugosidade da superfície da resina acrílica que os demais desinfetantes testados.


The aim of this study was to evaluate the effect of disinfection associated to brushing the superficial crease (Ra and Rz) of heat-polymerized acrylic resin. Fifty cylinders of 0.5mm x o.5mm acrylic resin (Lucitone 550 Dentsply) were produced by using the short thermal cycle of polymerization (73ºC for 90 minutes and then immersion on water at the temperature of 94ºC for 30 minutes), according to the manufacturer’s instructions. The thermo-polymerized samples were immersed in distilled water at the temperature of 37ºC (plus or minus 1ºC) for 48 hours and divided into 5 groups (n=10) according to the disinfection method, that is: GrControl – no chemical disinfection nor brushing; Gr1 – distilled water and brushing; Gr2 – sodium hypoclorite 1% and brushing; Gr3 – chlorexidine gluconate 2% and brushing and G4 – sodium perborate 3,78% and brushing. The groups were immersed for 5 minutes before brushing cycle (10.000 cycles) and the values for Ra and Rz were analyzed with crease contact measuring instrument(contact profilometer). Results were statistically analyzed by the ANOVA method. The arithmetic means were compared by the Tukey test (ά=0.05). RESULTS: The arithmetic means obtained for Ra and Rz were : GrControl 0.16(0.03) and 0.77 (0.21); Gr1 0.3(0.13) and 1.25(0.62); Gr2 0.24(0.09) and 1.02(0.4); Gr3 0.34(0.14) and 1.45(0.55); Gr4 0.38(0.14) and 1.7(0.65) . The ANOVA test revealed that the roughness for the two parameters was significantly affected by brushing with toothpaste (PRa =0.0009; PRz=0.0021) .Tooth brushing together with sodium hypoclorite results in a lessened effect over the surface crease of the acrylic resin than other tested disinfectants


Subject(s)
Acrylic Resins , Disinfection
5.
Braz. dent. sci ; 12(4): 12-17, out.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-587931

ABSTRACT

Este trabalho avaliou as adaptações cervicais de copings cerâmicos, confeccionados pelos Sistemas Empress 2 e In-Ceram, variando-se os términos cervicais dos preparos em chanfro largo e ombro 90° arredondado; em preparos com 15° de conicidade, e 2 tipos de agentes para cimentação: o cimento de fosfato de zinco e um cimento resinoso. Foram confeccionados dois modelos-padrão de aço inoxidável. A partir destes obtiveram-se 40 troquéis em gesso tipo V, sendo 20 para cada sistema e 10 para cada tipo de término cervical e os copings cerâmicos correspondentes para cada sistema. Em seguida, o conjunto foi levado ao metroscópio horizontal para a primeira leitura (L0). Procedeu-se a cimentação, inicialmente sob pressão digital, em seguida com a aplicação de carga padronizada e efetuou-se a segunda medida (L1).Após a coleta dos dados, foi realizada a análise estatística das médias das medidas aferidas e as seguintes conclusões foram alcançadas: a) o cimento de fosfato apresentou um valor médio de discrepância de assentamento, para os dois sistemas, menor do que o resinoso; b) término cervical em chanfro e ombro arredondado, para qualquer um dos sistemas, mostraram resultados semelhantes; c) o sistema In-Ceram apresentou um valor médio de discrepância assentamento menor que o IPS Empress 2, porém não significante estatisticamente.


The aim of this study was to assess the cervical adjustments of ceramic copings, using two ceramic systems, the Empress 2 and In-Ceram, varying the cervical end of the preparations and the types of cements: zinc phosphate and resin cement. Initially two standard models of stainless steel were made. From these models 40 stone dies were made, 20 for each system and 10 for each type of cervical end. A specialized commercial laboratory made the ceramic copings corresponding to each system. Then, the set was brought to the horizontal metroscopic for first measure, called L0. The cementing process was done, initially under digital pressure, and then with the implementation of standardized load, when the second measure, called L1, was done. After collecting the data, statistical analysis was carried out. We could conclude that- a) zinc phosphate cement showed less settlement discrepancy, for both systems, than the resin cement b) rounded shoulder and chamfer ends showed similar results, c) In-Ceram system had less settlement discrepancy, but not statistically significant, than IPS Empress 2.


Subject(s)
Dental Marginal Adaptation , Ceramics
6.
Braz. dent. sci ; 12(4): 34-39, out.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-587938

ABSTRACT

O objetivo deste estudo foi avaliar a influência de dispositivos de microtração sobre a resistência coesiva de blocos de resina acrílica. Vinte blocos de resina acrílica termopolimerizável (Onda-Cryl Clássico) foram confeccionados e distribuídos em 4 diferentes grupos experimentais (n=5) de acordo com o dispositivo de microtração empregado: G1: Paquímetro modificado; G2: Dispositivo de Andreatta Filho; G3: Dispositivo de Borges; G4: MT-jig. Os blocos foram seccionados em palitos de lmm2 e submetidos ao teste de microtração (EMIC DL 1000). Os dados foram avaliados pela Análise de Variância e pelo Teste de Tukey, a 5% de significância. Os menores valores de resistência mecânica foram obtidos com os dispositivos de Andreatta Filho (34,22 MPa) e de Borges (34,49 MPa), e os maiores valores com o Paquímetro modificado (49,44 MPa) e o MT-jig (48,40 MPa). Concluiu-se que os valores de resistência mecânica são influenciados pelos dispositivos de microtração utilizados e que não podem ser comparados entre si.


The aim of this study was to assess the influence of different devices on microlensile strength of acrylic resin blocks. Twenty thermo polyrnerized acrylic resin blocks (Onda-Cryl Clássico) were produced and divided into four experimental groups (n=5) according to microtensile device used: G I: Modified caliper; G2: Andreatta Filho’s device: G3: Borges' device: G4: MT-jig. Blocks were sectioned into sticks with a crosssection of I rnm2- and tested to failure in tension mode (EMIC DL 1000). The data were submitted to l-way analysis of variance (AOVA), followed by Tukey’s test (a=.05). The lowest mean microtensile strengths were obtained with Andreatta Filhos (34.22 MPa) and Borges' (34.49 MPa) devices. Paquimeter (49.44 MPa) and MT-jig (48.40 MPa) promoted the highest mean microtensile strengths, 1t was concluded that microtensile devices influence mechanical strength values.


Subject(s)
Acrylic Resins , Tensile Strength
7.
RSBO (Impr.) ; 6(2): 163-168, jun. 2009. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-514884

ABSTRACT

Introdução e objetivo: Buscou-se avaliar in vitro o grau de aquecimento promovido no interior da câmara pulpar após o uso de diferentes agentes clareadores, com ou sem ativação por fontes de luz. Material e métodos: Foram utilizados 60 dentes incisivos bovinos, que receberam acesso ao canal radicular pela face lingual, com a parede vestibular padronizada em 2 mm. Os espécimes foram divididos em 6 grupos (n = 10), de acordo com o agente clareador e a fonte de ativação utilizada: G1 - ausência de agente clareador e aplicação de luz halógena; G2 - ausência de agente clareador e aplicação de LED; G3 - aplicação do agente clareador Whiteness HP Maxx (peróxido de hidrogênio 35%) e ativação com luz halógena; G4 - aplicação do agente clareador Whiteness HP Maxx (peróxido de hidrogênio 35%) e ativação com LED; G5 - aplicação do agente clareador Opalescence Xtra Boost (peróxido de hidrogênio 38%) e ativação com fotopolimerizador; G6 - aplicação do agente clareador Opalescence Xtra Boost (peróxido de hidrogênio 38%) e ativação com LED. A variação da temperatura na câmara pulpar foi mensurada com um aparelho termopar. Resultados: Os valores de temperatura foram medidos pelo aparelho durante 10 minutos, com alguns intervalos selecionados: t1 - temperatura inicial; t2 - após 25 segundos de aplicação do gel e 20 segundos de ativação; t3 - após 10 minutos. Os valores obtidos foram registrados pela máquina no software, e os dados foram submetidos à análise estatística pelo teste Anova. Verificou-se que o aumento da temperatura não foi significante em todos os grupos testados. Conclusão: Não foram encontradas diferenças estatisticamente significantes entre os grupos com e sem ativação por fontes de luz ou entre os diferentes clareadores.


Introduction and objective: To evaluate in vitro the degree of warming promoted within the pulp chamber, after the use of bleaching agents, with or without activation by light sources. Material and methods: Sixty bovine teeth were used, which had received access to the root canal by the side lingual, with the wall vestibular standardized at 2 mm. The specimens were divided into 6 groups (n = 10), according to the bleaching agent and the source of activation used: G1 - absence of bleaching agent and application of halogen light; G2 - absence of bleaching agent and application of LED; G3 - application of the Whiteness HP Maxx (35% hydrogen peroxide) and activation with halogen light; G4 - application of Whiteness HP Maxx (35% hydrogen peroxide) and activation with LED; G5 - application of the Opalescence Xtra Boost (38% hydrogen peroxide) and activation with photopolymerizer; G6 - application of the Opalescence Xtra Boost (38% hydrogen peroxide) and activation with LED. The change of temperature in the pulp chamber was measured using a Termopar apparatus. Results: The values of temperature were measured by the device during an interval of 10 minutes, with some selected intervals: t1 - initial temperature; t2 - after 25 seconds of application of the gel and 20 seconds of activation; t3 - after 10 minutes. The values were registered by the machine in the software and the data were subjected to statistical analysis using the Anova test. Conclusion: There were no statistically significant differences between groups with and without activation or between different bleaching.

8.
Ciênc. odontol. bras ; 12(1): 23-30, 2009. tab, ilus, graf
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-524151

ABSTRACT

Objetivo: Este estudo propôs avaliar a microdureza de diferentes resinas compostas de uso direto (rcd) e indireto (rci). Materiais e Métodos: Com o auxílio de uma matriz metálica (diâmetro: 5,0mm; espessura: 2,0mm) foram confeccionadas 70 amostras, sendo (n=10) três resinas de uso direto: Gr1- Z250(3M ESPE/EUA), Gr2- W3D(Wilcos/Brasil) e Gr3- Esthetic X(Dentisply/EUA); e quatro de uso indireto: Gr4- Resilab Master (Wilcos/Brasil), Gr5- Vita VM LC (Vita Zahnfabrik/Alemanha), Gr6- Vita Zeta (Vita Zahnfabrik/Alemanha) e Gr7- Sinfony (3M ESPE/EUA). As amostras das rcd foram confeccionadas utilizando a técnica incremental, onde cada incremento de resina foi fotopolimerizado durante 40 segundos. Já as amostras da rci foram polimerizadas segundo recomendações dos fabricantes. Todos os espécimes foram armazenados em água destilada a 37ºC durante 24 horas. O teste de microdureza foi realizado em microdurômetro digital (Future-Tech,Modelo FM 700), com carga de 50 kgf por 15 segundos. Os dados obtidos (Kgf/mm2) foram analisados utilizando o teste não paramétrico de Kruskal-Wallis e o de comparação múltipla de Dunn (p<0.05). Resultados: As medidas resumo-numéricas de microdureza obtidas foram (mediana; média ± desvio padrão): Gr1 (100,12; 101,07± 5,99 Kgf/mm2), Gr2 (83,55; 84,20± 5,07 Kgf/mm2), Gr3 (73,98; 73,95± 6,55 Kgf/mm2), Gr4 (52,50; 52,54± 5,9 Kgf/mm2), Gr5 (33,25; 34,36± 2,29 Kgf/mm2), Gr6 (29,60; 29.68± 1.52 Kgf/mm2), Gr7 (25,39; 25.13± 2.08 Kgf/mm2). Verificou-se que os valores de microdureza das rcd analisadas não diferiram estatisticamente entre si (p<0,05). O mesmo não se pode estabelecer para as resinas indiretas, pois a Sinfony diferiu da Resilab (p<0,05). Conclusão: Baseado nos resultados pôde-se concluir que apenas a resina composta direta Z250 apresentou valores de microdureza Vickers superior às demais resinas indiretas.


Subject(s)
Composite Resins , Hardness Tests
9.
Braz Oral Res ; 22(3): 264-9, 2008.
Article in English | MEDLINE | ID: mdl-18949314

ABSTRACT

This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45 degrees angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 +/- 1.3 MPa) were statistically higher than those of G2 (3.9 +/- 2.2 MPa) and G3 (3.3 +/- 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.


Subject(s)
Ceramics/chemistry , Dental Bonding/methods , Dentin/chemistry , Post and Core Technique/instrumentation , Resin Cements/chemistry , Zirconium/chemistry , Analysis of Variance , Dental Stress Analysis/methods , Humans , Materials Testing , Post and Core Technique/standards , Root Canal Preparation , Stress, Mechanical , Tensile Strength
10.
J Adhes Dent ; 10(2): 127-33, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18512510

ABSTRACT

PURPOSE: This study evaluated the bond strength of two etch-and-rinse adhesive systems (two- and three-step) and a self-etching system to coronal and root canal dentin. MATERIALS AND METHODS: The root canals of 30 human incisors and canines were instrumented and prepared with burs. The posts used for luting were duplicated with dual resin cement (Duo-link) inside Aestheti Plus #2 molds. Thus, three groups were formed (n = 10) according to the adhesive system employed: All-Bond 2 (TE3) + resin cement post (rcp) + Duo-link (Dl); One-Step Plus (TE2) + rcp + Dl; Tyrian/One-Step Plus (SE) + rcp + Dl. Afterwards, 8 transverse sections (1.5 mm) were cut from 4 mm above the CEJ up to 4 mm short of the root canal apex, comprising coronal and root canal dentin. The sections were submitted to push-out testing in a universal testing machine EMIC (1 mm/min). Bond strength data were analyzed with two-way repeated measures ANOVA and Tukey's test (p < 0.05). RESULTS: The relationship between the adhesives was not the same in the different regions (p < 0.05). Comparison of the means achieved with the adhesives in each region (Tukey; p < 0.05) revealed that TE3 (mean +/- standard deviation: 5.22 +/- 1.70) was higher than TE2 (2.60 +/- 1.74) and SE (1.68 +/- 1.85). CONCLUSION: Under the experimental conditions, better bonding to dentin was achieved using the three-step etch-and-rinse system, especially in the coronal region. Therefore, the traditional etch-and-rinse three-step adhesive system seems to be the best choice for teeth needing adhesive endodontic restorations.


Subject(s)
Dental Bonding , Dental Pulp Cavity/ultrastructure , Dentin-Bonding Agents/classification , Dentin/ultrastructure , Tooth Crown/ultrastructure , Acid Etching, Dental , Cuspid , Dental Materials/chemistry , Dentin-Bonding Agents/chemistry , Humans , Incisor , Materials Testing , Methacrylates/chemistry , Post and Core Technique/instrumentation , Resin Cements/chemistry , Root Canal Preparation/methods , Stress, Mechanical
11.
RSBO (Impr.) ; 5(1): 11-17, abr. 2008. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-482754

ABSTRACT

Introdução: A capacidade de aderência de Candida albicans é um dos seus principais fatores de virulência. Superfícies de materiais diferentes podem propiciar condições para maior ou menor aderência e maior virulência dos microrganismos. Objetivo: Avaliar a aderência de Candida albicans em ligas de titânio e cobalto-cromo, com diferentes desgastes. Material e métodos: Foram confeccionados 24 corpos-deprova (CPs) cilíndricos, 12 de titânio e 12 de cobalto-cromo, divididos em 4 grupos de seis. Todos foram polidos de forma habitual pelo mesmo técnico. Os CPs foram lixados em torno de alta rotação por 15 segundos cada lixa, por toda a sua superfície. Um grupo de cada metal foi lixado apenas com lixa para metal número 80. Os dois outros grupos foram lixados conforme a seqüência (granulação decrescente): 80, 150 e 220. Os CPs foram esterilizados e posicionados em placas de cultura de células. Em cada poço da placa foi adicionada quantidade padronizada de caldo Sabouraud e suspensão contendo 106 céls./mL de C. albicans (ATCC 18804). Após incubação, o número de células aderidas por mm2 foi obtido pelo método de semeadura em placa de Petri. Os valores encontrados foram tabulados e submetidos aos testes de ANOVA e Tukey, com nível de significância de 5%. Resultados: Houve diferença estatística para a granulação de lixas, e não houve diferença quando foram comparados os metais. Conclusão: Quanto maior ?? a granulação final da lixa maior é a aderência, e o tipo de metal não influenciou no resultado.


Introduction: The capacity of Candida albicans adherence is one of its main factors of virulence. Surfaces of different materials can propitiate conditions for higher or lower adherence and greater virulence of the microorganisms. Objective: Evaluate the adherence of Candida albicans in cobalto-chromium and titanium alloys, with different sandpapering. Material and methods: Twenty-four cylindrical samples have been constructed, 12 of titanium and 12 of cobalt-chromium, divided in 4 groups of six. All have been polished in the habitual form by the same technician. Samples have been sandpapered at about high rotation for 15 seconds each sandpaper, on all its surface. A group of each metal was sandpapered only with sandpaper for metal number 80. The two other groups have been sandpapered in agreement with the sequence (decreasing granulation): 80, 150 and 220. Samples have been sterilized and located in plates of cells culture. In each well of the plate was added standardized amount of Sabouraud broth and suspension containing 106 cells per milliliter of C. albicans (ATCC 18804). After incubation, the number of adhered cells per mm2 was obtained by the method of sowing in plate of Petri. The obtained values have been tabulated and submitted to the tests of ANOVA and Tukey, with level of significance of 5%. Results: There was statistical difference for the granulation of sandpapers, what not occurred when considering metals. Conclusion: The bigger the final granulation of sandpaper, the greater the adherence and the type of metal did not influence in the result.

12.
Braz. oral res ; 22(3): 264-269, 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-495603

ABSTRACT

This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.


Subject(s)
Humans , Ceramics/chemistry , Dental Bonding/methods , Dentin/chemistry , Post and Core Technique/instrumentation , Resin Cements/chemistry , Zirconium/chemistry , Analysis of Variance , Dental Stress Analysis/methods , Materials Testing , Post and Core Technique/standards , Root Canal Preparation , Stress, Mechanical , Tensile Strength
13.
Ciênc. odontol. bras ; 10(2): 10-15, abr.-jun. 2007.
Article in English | LILACS, BBO - Dentistry | ID: lil-518109

ABSTRACT

Objective: To evaluate different methods of additional polymerization in the VickersÆ microhardness of three composite resins. Material and Methods: With assistance of a metallic matrix (3 x 4mm), 30 specimens (sps) of each direct resincomposite (drc) were prepared, entitled: Filtek Z250(3M ESPE, Saint Paul/MN-USA)(Gr1), W3D(Wilcos, Petrópolis/RJ-Brazil)(Gr2), and EstheticX (Dentsply/York/PA-USA)(Gr3). All sps were photopolimerized, by the incrementaltechnique, during 40 seconds (Gr1 - n=10: control). After that, 20 samples of each group were divided and half of thesamples (n=10) were submitted to the additional polymerization during 15 minutes to 127ºC in autoclave (Gr2) and theother half in stove (Gr3). After all sps were stored in distilled water (37ºC/24 hours). The microhardness was accomplishedin digital machine (Future-Tech, FM 700 Model), with 50kg of load. The data obtained (Kg/mm2) were analyzedutilizing the ANOVA Test (2 factors) and Tukey test (p<0.05). Results: The values of mean ± standard deviations obtainedwere: Gr1a(84,2±5,1), Gr1b (71,6±6,7), Gr1c (89,6±7,4), Gr2a (101,1±6,0), Gr2b (96,4±9,0), Gr2c (112,6±7,3), Gr3a(74,0±6,5), Gr3b (66,0±12,7) e Gr3c (81,7±6,5). The polymerization in stove produced a higher microhardness than theother kinds of polymerization (p<0.05) and the microhardness of the resins statistically differed among them (p<0.05).Conclusion: The additional polymerization of the Filtek Z250 in the stove produced microhardness statistically higherthan the others.


Objetivo: Frente à possibilidade de se utilizar resinas compostas diretas (rcds) para procedimentos restauradores indiretos,o presente estudo propôs avaliar diferentes métodos de polimerização adicional na microdureza VickersÆ de trêsresinas compostas de uso direto. Materiais e Métodos: Com o auxílio de uma matriz metálica (3,0 x 4,0mm), foramconfeccionados 30 corpos-de-prova de cada resina denominadas: W3D(Wilcos/Brasil)(Gr1), Z250(3M ESPE/EUA)(Gr2) e Esthetic X(Dentisply/EUA)(Gr3). Todos os espécimes (sps) foram fotopolimerizados, pela técnica incremental,durante 40 segundos (Gr1 - n=10: controle). Em seguida, 20 amostras de cada grupo foram aleatoriamente divididas emetade das amostras (n=10) submetidas à polimerização adicional durante 15 minutos a 127ºC em autoclave (Gr2) e aoutra parte em estufa (Gr3). Após todos os sps foram armazenados em água destilada a 37ºC durante 24 horas. O testede microdureza foi realizado em microdurômetro (Future-Tech, Modelo FM 700), com força de 50 kg. Os dados obtidos(Kg/mm2) foram analisados utilizando o teste ANOVA (2 fatores) e o teste t (Tukey) (p<0.05). Resultados: Os valores demédias±desvios padrões obtidos foram: Gr1a(84,2±5,1), Gr1b (71,6±6,7), Gr1c (89,6±7,4), Gr2a (101,1±6,0), Gr2b(96,4±9,0), Gr2c (112,6±7,3), Gr3a (74,0±6,5), Gr3b (66,0±12,7) e Gr3c (81,7±6,5). Observou-se que a polimerizaçãoem estufa gerou maior microdureza que as demais polimerizações (p<0,05) e que a microdureza das resinas diferiuestatisticamente entre si (p<0,05). Conclusão: Dessa forma, é lícito concluir que a polimerização adicional da Z250na estufa gerou microdureza estatisticamente superior aos demais grupos.


Subject(s)
Composite Resins , Hardness Tests , Analysis of Variance
14.
Ciênc. odontol. bras ; 8(3): 22-28, jul.-set. 2005. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-450412

ABSTRACT

O objetivo deste trabalho in vivo foi avaliar a adaptação de apoios em cíngulo confeccionados sobre esmalte ou resina composta em Próteses Parciais Removíveis. Após a prova e ajuste da armação metálica e anteriormente ao registro da relação maxilo-mandibular foram selecionados caninos com apoios considerados adaptados clinicamente, totalizando uma amostra de 16 apoios em esmalte (Grupo A) e 16 apoios em resina composta (Grupo B). A adaptação foi verificada utilizando uma silicona por condensação leve (Heraeus Kulzer). O material foi manipulado e colocado na face interna do apoio, em seguida a armação metálica foi inserida na boca de acordo com a trajetória de inserção até a posição de assentamento final. Após a polimerização, o material adere a armação metálica que foi removida da boca. Outra silicona por condensação média (3M) foi colocada sobre o material anterior, formando o corpo-de-prova, que foi seccionado longitudinalmente na região mais profunda do preparo. Sua espessura mostrou o grau de adaptação entre a fundição e o dente suporte. As medidas foram feitas utilizando projetor de perfil (MP320- Carl Zeiss, JENA). Os resultados foram analisados através do Teste de Mann-Whitney (5%), onde foi observada uma diferença significante (p=0,017) entre os dois grupos(Grupo A= 0,584 ± 0,325mm e Grupo B= 0,311 ± 0,237mm). Os apoios confeccionados sobre resina composta apresentaram uma melhor adaptação ao preparo para apoio do que os realizados sobre esmalte.


Subject(s)
Humans , Composite Resins , Dental Abutments , Dental Enamel , Dental Materials , Denture, Partial, Removable , Statistics, Nonparametric
15.
Rev. Odontol. Araçatuba (Impr.) ; 25(2): 51-56, jul.-dez. 2004. ilus, tab, graf
Article in Portuguese | BBO - Dentistry | ID: biblio-856734

ABSTRACT

Os condicionadores de tecido são materiais temporários, indicados principalmente para tratamento dos tecidos fibromucosos inflamados e reembasamentos de próteses provisórias durante o período de osseointegração de implantes. O objetivo deste estudo foi avaliar, in vitro, alterações na resiliência de dois condicionadores de tecido associados ou não ao uso de selante, em diferentes intervalos de tempo. Foram confeccionadas cápsulas de resina acrílica termicamente ativada, com 20mm de diâmetro interno e 2mm de profundidade. Os condicionadores de tecido, Coe Comfort (GC America) e Ufi Gel (Voco) foram preparados conforme indicação dos fabricantes e acomodados no interior das cápsulas totalizando 15 corpos de prova. Os corpos de prova foram divididos em 3 grupos iguais: um para o Coe Comfort (CC), um para o UfiGel com selante de superfície (UG) e outro para o Ufi Gel sem selante (UGS). Cada corpo de prova foi submetido ao teste de penetração com uma ponta romba de 3mm de diâmetro em máquina de ensaio universal (EMIC-DL1000). Os testes foram realizados nos intervalos: 1 hora após sua obtenção e, 1, 7, 14 e 21 dias. Durante os intervalos, os corpos de prova foram mantidos submersos em saliva artificial a 37ºC.Os resultados foram submetidos à análise estatística ANOVA (ONE WAY; p<0,05). Não houve diferença estatística significante para os grupos CC e UG e houve diferença significante para o grupo UGS. Concluiu-se que a não aplicação do selante de superfície no Ufi Gel pode diminuir o período de resiliência e a longevidade do condicionador de tecido


Subject(s)
Dental Prosthesis , Denture Liners , Osseointegration , Pit and Fissure Sealants
16.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 6(29): 102-108, jan.-fev. 2004. ilus, CD-ROM
Article in Spanish, Portuguese | BBO - Dentistry | ID: biblio-853066

ABSTRACT

Em casos onde há perda de elementos dentários e onde a reabilitação mais indicada é a prótese parcial removível (PPR), deparamo-nos com um sério problema, restabelecer a função sem prejuízos estéticos. Este trabalho visa a relatar a utilização do grampo Twin-Flex, uma alternativa para melhorar a estética sem descuidar dos aspectos biomecânicos das PPR


Subject(s)
Humans , Female
17.
Ciênc. odontol. bras ; 6(2): 88-97, abr.-jun. 2003. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-385909

ABSTRACT

O objetivo desta pesquisa foi estudar resistência à tração de cápsulas cimentadas a troqueis metálicos, com cimento fosfato de zinco, variando o alívio interno nas cápsulas e sulcos horizontais nas cápsulas e nos troqueis. Foram usinados em torno computadorizado (CNC), 288 cilindros, em aço inoxidável, simulando preparos para coroas totais (144) e respectivas coroas (144). Foram estabelecidas quarenta e oito condições experimentais, replicadas três vezes. Ajuste técnico de 2um foi feito em todas as cápsulas para permitir assentamento. As cápsulas foram divididas em três grupos iguais em função do alívio. O grupo A não foi aliviado, os grupos B e C receberam 30um e 60um respectivamente. A quantidade de sulcos variou entre zero e três, tanto nas cápsulas como nos troqueis. A profundidade dos sulcos foi de 200um. Os corpos-de-prova obtidos das cimentações com cimento fosfato de zinco foram submetidos a ensaio de tração em máquina universal de ensaios (Emic-Itaquaquecetuba-SP), no Departamento de Materiais e Tecnologia da Faculdade de Engenharia de Guaratinguetá, UNESP. Os resultados numéricos foram submetidos a tratamento estatístico (Análise de Variância e teste de Tukey). Os resultados mostraram diferença estatística significante (5 por cento), individualmente e na interação das variáveis, alívio e quantidade de sulcos nas cápsulas. Não houve diferença estatística quanto à quantidade de sulcos nos troqueis. A análise dos resultados permitiu concluir que a resistência à tração: aumentou com o aumento do alívio e com a quantidade de sulcos na cápsulas; permaneceu inalteradas com os sulcos nos troqueis; parece ser limitada pelas variáveiis estabelecidas para o troquel.


Subject(s)
Cementation , Dental Prosthesis , Dental Prosthesis Retention
18.
Pós-Grad. Rev ; 4(2): 60-4, maio-ago. 2001. ilus, CD-ROM
Article in Portuguese | BBO - Dentistry | ID: biblio-854064

ABSTRACT

Minimizar discrepância de assentamento tem sido a razão de muitas pesquisas nos últimos tempos, visando melhorar a qualidade de adaptação das próteses dentárias. Entretanto, respeitados autores tem relatado resultados apresentando valores aparentemente incoerentes, isto é, melhor assentamento vertical de coroas totais após a cimentação, quando, devido à ausência de cimento interposto o inverso seria o esperado. Este fato levou-nos a desenvolver o presente trabalho. Assim, um dispositivo mecânico foi desenvolvido para padronizar e manter constante a pressão de assentamento durante todo o processo de mensuração (nas situações: sem cimento e após a cimentação)...


Subject(s)
Dental Prosthesis
19.
PCL ; 3(14): 291-6, jul.-ago. 2001. ilus, CD-ROM
Article in Portuguese | BBO - Dentistry | ID: biblio-853245

ABSTRACT

Este trabalho descreve a confecção de uma Prótese Parcial Removível (PPR) atípica, que recobre as superfícies oclusais dos dentes suportes, definida na literatura como PPR Overlay. Este tipo de prótese é usado geralmente em casos de desgaste severo da superfície oclusal ou em casos de mordida aberta com grande trespasse vertical. A principal vantagem desta opção de tratamento é ser reversível, além de apresentar menor custo e menor tempo operacional. Um caso clínico é apresentado como ilustração


Subject(s)
Humans , Female , Middle Aged , Dental Occlusion , Denture, Partial, Removable , Dental Materials , Models, Dental , Mouth Rehabilitation
20.
PCL ; 3(12): 127-31, mar.-abr. 2001. ilus, CD-ROM
Article in Portuguese | BBO - Dentistry | ID: biblio-853234

ABSTRACT

O objetivo deste trabalho foi revisar a literatura, sintetizando os princípios de oclusão que deveriam ser respeitados, nos tratamentos onde se pretende indicar prótese fixa adesiva. Em princípio, confirmou-se a idéia de que os conceitos válidos para uma prótese fixa tradicional, também são válidos para as próteses adesivas. Todavia, parece ser consenso entre a maioria dos autores, de que para as próteses dependentes da adesividade dos cimentos para sua longevidade, há a necessidade de se encontrar a melhor forma de distribuição das forças oclusais, desenvolvidas na mastigação, no sentido de orientá-las em direção paralela ao longo eixo dos dentes de fixação, minimizando assim as tensões de deslocamento geradas sobre o agente de união. Da mesma forma, cuidados especiais devem ser tomados com os contatos oclusais durante os movimentos excêntricos, pois a possibilidade de deslocamento da prótese, nesses casos, é ainda mais acentuada


Subject(s)
Dental Occlusion , Denture, Partial, Fixed, Resin-Bonded , Bite Force
SELECTION OF CITATIONS
SEARCH DETAIL
...