Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Endoscopy ; 41(5): 445-8, 2009 May.
Article in English | MEDLINE | ID: mdl-19418399

ABSTRACT

BACKGROUND AND STUDY AIMS: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is now performed routinely in many advanced endoscopy centers and has enhanced the ability to diagnose pancreatic masses. However, there is uncertainty about which needle size is optimal for EUS-FNA of pancreatic masses. We aimed to evaluate the performance of the 22-gauge and 25-gauge needles in obtaining cytologic diagnosis of pancreatic masses. METHODS: All cases that were referred for EUS-FNA for pancreatic masses between February 2001 and June 2007 were reviewed, and patients who underwent EUS-FNA using the 22-gauge and 25-gauge needle system were identified. In patients who underwent surgery, operative histopathological findings were compared with the cytopathological findings from EUS-FNA. RESULTS: A total of 842 patients with pancreatic masses detected on computed tomography (CT) and/or magnetic resonance imaging (MRI) and confirmed by EUS underwent EUS-FNA with the 22-gauge needle (n = 540) or the 25-gauge needle (n = 302). Results of EUS-FNA cytology findings were compared with the gold standard of surgical histopathological findings or long-term clinical follow-up. The sensitivity, specificity, PPV, and NPV of FNA were respectively 84%, 100%, 100%, and 73% [corrected] for the 22-gauge needle compared with 92%, 97%, 98%, and 87%, [corrected] respectively for the 25-gauge needle. No complications were noted in the 25-gauge needle group, compared with pancreatitis in 2% of the 22-gauge needle group. CONCLUSIONS: This retrospective comparative study shows that EUS-FNA with a 25-gauge needle system is a safe and reliable method for tissue sampling in pancreatic masses. The system is more sensitive and has a slightly [corrected] higher NPV than the standard 22-gauge needle. Our study suggests that perhaps the smaller caliber FNA needle causes less trauma during EUS-FNA and hence less complications. Further studies including randomized trials are needed.


Subject(s)
Biopsy, Fine-Needle/instrumentation , Endosonography/instrumentation , Pancreatic Neoplasms/pathology , Ultrasonography, Interventional/instrumentation , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle/adverse effects , Diagnosis, Differential , Equipment Design , Female , Humans , Male , Middle Aged , Needles , Pancreas/pathology , Pancreatitis/etiology , Retrospective Studies , Sensitivity and Specificity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...