Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Hellenic J Cardiol ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38663567

ABSTRACT

BACKGROUND: Long-term data showed that up to 27% of pulmonary veins are reconnected using cryoballoon ablation. This study aimed to evaluate the efficacy of the latest 4th-generation cryoballoon catheters using ultra high-resolution mapping. METHODS: In patients with atrial fibrillation, a standard pulmonary vein isolation (PVI) with the latest 4th-generation cryoballoon catheter (Arctic Front Advance PRO, Medtronic Minneapolis, USA) and the spiral mapping catheter (Achieve Advance, Medtronic, Minneapolis, MN, USA) was performed. Subsequently, high-resolution mapping was achieved using the novel multipolar grid mapping catheter (Advisor HD Grid SE, Abbott Laboratories, USA). Follow-up was obtained after 6 months by means of a 7-day Holter electrocardiogram. RESULTS: In our study, acute PVI was successfully achieved in all 31 patients. The latest 4th-generation cryoballoon catheter is safe in the acute phase of PVI. Additional high-resolution mapping (mean points per map 21,001 ± 4911) using the multipolar grid mapping catheter enabled us to identify residual gaps only in the carina pulmonary vein region; therefore, no additional ablation was performed. Three of 31 patients (10%) presented with atrial arrhythmia recurrence always related with pulmonary vein reconnection; using high-resolution mapping had no additional benefit in identifying pulmonary veins in which reconnection will occur. CONCLUSION: The utility of additional high-density mapping, facilitated by the HD Grid catheter after PVI with the 4th-generation cryoballoon catheter do not substantiate a discernible advantage over conventional mapping methodologies, particularly, the spiral mapping catheter. Residual carinal conduction was observed in a substantial cohort of patients (48%), highlighting a persistent challenge in achieving complete electrical isolation.

2.
Rev Cardiovasc Med ; 16(1): 9-19, 2015.
Article in English | MEDLINE | ID: mdl-25813792

ABSTRACT

This review summarizes the data challenging the concept that cardiovascular protection through high-density lipoprotein (HDL) is only associated with its serum concentration. This conventional impression about its protective role now appears obsolete. New aspects of its mechanisms are revealed and novel therapeutic strategies are based on them. However, data from long-term cost-effectiveness studies of treating HDL are still needed. There is a need for biomarkers that represent the functional characteristics of HDL in order to better quantify the total cardiovascular risk.

SELECTION OF CITATIONS
SEARCH DETAIL
...