Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 75
Filter
1.
J Can Assoc Gastroenterol ; 7(3): 246-254, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38841140

ABSTRACT

Background and study aim: Magnifying endoscopy enables the diagnosis of advanced neoplasia throughout the gastrointestinal tract. The unified magnifying endoscopic classification (UMEC) framework unifies optical diagnosis criteria in the esophagus, stomach, and colon, dividing lesions into three categories: non-neoplastic, intramucosal neoplasia, and deep submucosal invasive cancer. This study aims to ascertain the performance of North American endoscopists when using the UMEC. Methods: In this retrospective cohort study, five North American endoscopists without prior training in magnifying endoscopy independently diagnosed images of gastrointestinal tract lesions using UMEC. All endoscopists were blinded to endoscopic findings and histopathological diagnosis. Using histopathology as the gold standard, the endoscopists' diagnostic performances using UMEC were evaluated. Results: A total of 299 lesions (77 esophagus, 92 stomach, and 130 colon) were assessed. For esophageal squamous cell carcinoma, the sensitivity, specificity, and accuracy ranged from 65.2% (95%CI: 50.9-77.9) to 87.0% (95%CI: 75.3-94.6), 77.4% (95%CI: 60.9-89.6) to 96.8% (95%CI: 86.8-99.8), and 75.3% to 87.0%, respectively. For gastric adenocarcinoma, the sensitivity, specificity, and accuracy ranged from 94.9% (95%CI: 85.0-99.1) to 100%, 52.9% (95%CI: 39.4-66.2) to 92.2% (95%CI: 82.7-97.5), and 73.3% to 93.3%. For colorectal adenocarcinoma, the sensitivity, specificity, and accuracy ranged from 76.2% (95%CI: 62.0-87.3) to 83.3% (95%CI: 70.3-92.5), 89.7% (95%CI: 82.1-94.9) to 97.7% (95%CI: 93.1-99.6), and 86.8% to 90.7%. Intraclass correlation coefficients indicated good to excellent reliability. Conclusion: UMEC is a simple classification that may be used to introduce endoscopists to magnifying narrow-band imaging and optical diagnosis, yielding satisfactory diagnostic accuracy.

3.
EClinicalMedicine ; 70: 102542, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38525407

ABSTRACT

Background: The multifactorial nature of inflammatory bowel disease (IBD), which manifests differently in individuals creates a need for a better understanding of the behaviour and pattern of the disease due to environmental factors. The current study aimed to study the changes in IBD behaviour, presentation, and characteristics in patients over the past two decades with a goal of improving patients' diagnosis, management and outcomes. Methods: During a 6-month period (1/02/2022-30/07/2022), the information of patients with IBD who attended IBD outpatient clinics of 11 referral centre's in six countries was collected, and based on the first time of diagnosis with IBD, they were allocated as group A (those who were diagnosed more than 15 years ago), group B (those who were diagnosed with IBD between 5 and 15 years ago) and group C (IBD cases who diagnosed in recent 5 years). Then the most prevalent subtypes and characters of the disease are evaluated and compared to make clear if the presenting pattern and behaviour of the disease has changed in the last 2 decades. Findings: Overall 1430 patients with IBD including 1207 patients with ulcerative colitis (UC) (84.5%) and 205 patients with Crohn's disease (CD; 14.3%) included. Mean age of participants at the first time of diagnosis with IBD was 30 years. The extra-intestinal involvement of IBD in groups A and B was more prevalent in comparison with group C. Most of those in groups A & B had academic education but in group C, the most prevalent educational status was high school or diploma (P = 0.012). In contrast to groups A and B, the relative prevalence of medium socioeconomic level in group C had decreased (65%). Relative prevalence of UC subtypes was similar among groups A and B (extensive colitis as most prevalent) but in group C, the most prevalent subtype is left side colitis (38.17%). The most prevalent subtype of CD in groups A and B was ileocolic involvement while in group C, upper GI involvement is significantly increased. The rate of food sensitivity among groups A and B was more than group C (P = 0.00001). The relative prevalence of patients with no flare has increased with a steady slope (P < 0.00001). Relative prevalence of presenting symptoms among patients with UC in group C differs and nowadays the rate abdominal pain (70.7%) and bloating (43.9%) have increased and frequency of diarrhoea (67.4%) has decreased. Interpretation: In the recent 5 years, the pattern of UC presentation has changed. The rate of upper GI involvement in CD and relative prevalence of patients with no disease flare increased and the rate of extra intestinal involvement decreased. Funding: None.

4.
Gastrointest Endosc ; 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38331224

ABSTRACT

BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large non-pedunculated colorectal polyps are often referred to expert centres for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of our study was to establish minimum expected standards for the referral of LNPCP for potential ER. METHODS: A Delphi methodology was employed to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and three rounds of surveys were conducted to achieve consensus, with quantitative and qualitative data analysed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographics, relevant medications, lesion factors, photodocumentation and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements ranged from 7.04 to 9.29 out of 10, with high percentages of experts considering most statements as a very high priority. Subgroup analysis by continent revealed some variations in consensus rates among experts from different regions. CONCLUSION: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.

5.
Molecules ; 29(4)2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38398525

ABSTRACT

This work compared the multi-element analysis of human hair and nails using inductively coupled plasma mass spectrometry (ICP MS) with an easy, fast, cheap, non-destructive method using energy-dispersive x-ray fluorescence (ED XRF). The ICP MS-based method was more sensitive (over 30 elements could be quantified) and costly (requiring more time, samples, and chemicals). The EDX-based method required laboratory and certified reference materials made of hair for instrument calibration. It was less sensitive (16 elements could be quantified: S, Si, Ca, Br, Fe, Cu, Cr, Mg, Si, K, Mn, Ni, Zn, Se, Sr, Pb), but it allowed us to replace troublesome grinding with the dissolution of keratin-based material with an alkalic agent (tetramethylammonium hydroxide, TMAH) and the formation of stable-for-days pellets. This method is simple, enables automation, and, due to the modification of wells in the autosampler of the EDX system via the immersion of home-designed inserts, it requires smaller amounts of biological material and binder (down to 70 mg instead of 500 mg required by commercially available instrument) to perform analysis. It was concluded that the EDX-based method offers complementary selectivity and sensitivity to ICP MS with the possibility of sample reuse for further analysis.

6.
Endoscopy ; 56(3): 244, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38417430
7.
World J Gastroenterol ; 30(1): 70-78, 2024 Jan 07.
Article in English | MEDLINE | ID: mdl-38293324

ABSTRACT

This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) as a salvage approach in cases of unsuccessful conventional management. EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery. The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events, making it a safe and effective option for appropriate candidates. Furthermore, EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture. However, patient selection is critical for the success of EUS-GBD, and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure. As the field continues to evolve and mature, ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD, ultimately leading to improved outcomes for patients.


Subject(s)
Cholecystitis, Acute , Gallbladder , Humans , Gallbladder/diagnostic imaging , Gallbladder/surgery , Stents , Endosonography/methods , Drainage/adverse effects , Drainage/methods , Cholecystitis, Acute/surgery , Ultrasonography, Interventional , Treatment Outcome
8.
Gastrointest Endosc ; 100(1): 27-35, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38215856

ABSTRACT

BACKGROUND AND AIMS: Cleanliness of the mucosa of the upper GI (UGI) tract is critical for performing a high-quality EGD. The aim of this study was to validate a recently developed UGI cleanliness scale (the Polprep: Effective Assessment of Cleanliness in Esophagogastroduodenoscopy [PEACE] system) in the detection of clinically significant lesions (CSLs) in the UGI tract. METHODS: Patients who underwent a complete diagnostic EGD were prospectively enrolled from August 2021 to October 2022. The UGI tract (esophagus, stomach, and duodenum) cleanliness was scored from 0 to 3 for each segment. The primary outcomes were the detection of CSLs and PEACE scores. RESULTS: Of 995 patients enrolled from 5 centers, adequate cleanliness (AQ; all scores ≥2) was found in 929 patients. In multivariate regression analysis, AQ was associated with the number of diagnosed CSLs (odds ratio [OR], 1.78; 95% confidence interval [CI], 1.06-3.01; P = .03). Other factors related to CSL detection were duration of EGD (OR, 1.29, 95% CI, 1.23-1.35, P < .001), male sex (OR, 1.33, 95% CI, 1.04-1.71; P = .025), and EGD indication (dyspepsia, alarm symptoms, gastritis surveillance, other indications vs GERD) (OR, 0.43 [95% CI, 0.31-0.6, P < .001], OR, 0.44 [95% CI, 0.28-0.67, P < .001], OR, 0.44 [95% CI, 0.25-0.76; P = .004], and OR, 0.44 [95% CI, 0.31-0.62; P < .001], respectively). Twenty-seven patients were diagnosed with UGI neoplasia, all in patients with adequate cleanliness of the UGI tract. CONCLUSIONS: Adequate cleanliness of the UGI tract as assessed with the PEACE system was associated with a significantly higher detection rate of CSLs during EGD. The relationship of this scale with UGI neoplasia detection warrants further investigation.


Subject(s)
Endoscopy, Digestive System , Humans , Male , Female , Endoscopy, Digestive System/methods , Middle Aged , Prospective Studies , Aged , Gastric Mucosa/pathology , Intestinal Mucosa/pathology , Adult , Esophageal Mucosa/pathology , Duodenum/pathology
9.
Endoscopy ; 56(2): 131-150, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38040025

ABSTRACT

This ESGE Position Statement provides structured and evidence-based guidance on the essential requirements and processes involved in training in basic gastrointestinal (GI) endoscopic procedures. The document outlines definitions; competencies required, and means to their assessment and maintenance; the structure and requirements of training programs; patient safety and medicolegal issues. 1: ESGE and ESGENA define basic endoscopic procedures as those procedures that are commonly indicated, generally accessible, and expected to be mastered (technically and cognitively) by the end of any core training program in gastrointestinal endoscopy. 2: ESGE and ESGENA consider the following as basic endoscopic procedures: diagnostic upper and lower GI endoscopy, as well as a limited range of interventions such as: tissue acquisition via cold biopsy forceps, polypectomy for lesions ≤ 10 mm, hemostasis techniques, enteral feeding tube placement, foreign body retrieval, dilation of simple esophageal strictures, and India ink tattooing of lesion location. 3: ESGE and ESGENA recommend that training in GI endoscopy should be subject to stringent formal requirements that ensure all ESGE key performance indicators (KPIs) are met. 4: Training in basic endoscopic procedures is a complex process and includes the development and acquisition of cognitive, technical/motor, and integrative skills. Therefore, ESGE and ESGENA recommend the use of validated tools to track the development of skills and assess competence. 5: ESGE and ESGENA recommend incorporating a multimodal approach to evaluating competence in basic GI endoscopic procedures, including procedural thresholds and the measurement and documentation of established ESGE KPIs. 7: ESGE and ESGENA recommend the continuous monitoring of ESGE KPIs during GI endoscopy training to ensure the trainee's maintenance of competence. 9: ESGE and ESGENA recommend that GI endoscopy training units fulfil the ESGE KPIs for endoscopy units and, furthermore, be capable of providing the dedicated personnel, infrastructure, and sufficient case volume required for successful training within a structured training program. 10: ESGE and ESGENA recommend that trainers in basic GI endoscopic procedures should be endoscopists with formal educational training in the teaching of endoscopy, which allows them to successfully and safely teach trainees.


Subject(s)
Gastroenterology , Humans , Endoscopy, Gastrointestinal/methods , Endoscopes, Gastrointestinal , Societies, Medical
12.
Am J Gastroenterol ; 2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37713525

ABSTRACT

INTRODUCTION: Polyp size determination plays an important role in endoscopic decision making and follow-up determination. However, there is a lack of knowledge of endoscopist accuracy for polyp sizing and efficacy of available tools for size measurement. Our aim was to compare the accuracy of visual assessment, snare, forceps, and virtual scale endoscope (VSE) in estimating polyp size among a diverse group of endoscopists. METHODS: We conducted a prospective video-based study. One hundred twenty polyps measured and recorded along with all available measurement tools were randomized to visual assessment, snare, forceps, or VSE group. Eleven endoscopists conducted video-based measurement using the randomized measurement tool. Primary outcome was relative accuracy in polyp size measurement compared with caliper measurement immediately postresection. RESULTS: One thousand three hundred twenty measurements were performed. VSE had statistically significantly higher relative accuracy when compared to forceps (79.3 vs 71.3%; P < 0.0001). Forceps had statistically significantly higher relative accuracy when compared to visual assessment (71.3 vs 63.6%; P = 0.0036). There was no statistically significant difference when comparing visual assessment and snare-based measurements (63.6 vs 62.8%; P = 0.797). Overall, 21.5% of polyps >5 mm were misclassified as ≤5 mm and 17.3% of polyps ≥10 mm were misclassified as <10 mm. VSE had the lowest percentage of polyps >5 mm misclassified as ≤5 mm (2.6%), polyps ≤5 mm misclassified as >5 mm (5.1%), and polyps <10 mm misclassified as ≥10 mm (1.7%). DISCUSSION: Visual size estimation of polyps is inaccurate independently of training level, sex, and specialty. Size measurement accuracy can be improved using forceps and yields the highest relative accuracy when an adaptive scale technology is used.

13.
VideoGIE ; 8(8): 328-329, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37575143

ABSTRACT

Video 1Colonic abnormalities observed in the course of systemic multiple myeloma.

14.
Turk J Gastroenterol ; 34(7): 771-778, 2023 07.
Article in English | MEDLINE | ID: mdl-37403979

ABSTRACT

BACKGROUND/AIMS: Groove pancreatitis is a rare form of focal pancreatitis that affects the groove area. Since groove pancreatitis may be mistaken for malignancy, it should be considered in patients with pancreatic head mass lesions or duodenal stenosis to avoid unnecessary surgical procedures. The aim of the study was to document the clinical, radiologic, endoscopic characteristics, and treatment outcomes of patients with groove pancreatitis. MATERIALS AND METHODS: This retrospective multicenter observational study included all patients diagnosed with one or more imaging criteria suggestive of groove pancreatitis in the participating centers. Patients with proven malignant fine-needle aspiration/biopsy results were excluded. All patients were followed in their own centers and were retrospectively evaluated. RESULTS: Out of the initially included 30 patients with imaging criteria suggestive of groove pancreatitis, 9 patients (30%) were excluded because of malignant endoscopic ultrasound fine-needle aspiration or biopsy results. The mean age of the included 21 patients was 49 ± 10.6 years, with a male predominance of 71%. There was a history of smoking in 66.7% and alcohol consumption in 76.2% of patients. The main endoscopic finding was gastric outlet obstruction observed in 16 patients (76%). There was duodenal wall thickening in 9 (42.8%), 5 (23.8%), and 16 (76.2%) patients on computed tomography, magnetic resonance imaging, and endoscopic ultrasound, respectively. Moreover, pancreatic head enlargement/mass was observed in 10 (47.6%), 8 (38%), and 12 (57%) patients, and duodenal wall cysts in 5 (23.8%), 1 (4.8%), and 11 (52.4%) patients, respectively. Conservative and endoscopic treatment has achieved favorable outcomes in more than 90% of patients. CONCLUSIONS: Groove pancreatitis should be considered in any case with duodenal stenosis, duodenal wall cysts, or thickening of the groove area. Various imaging modalities, including computerized tomography, endoscopic ultrasound, and magnetic resonance imaging, have a valuable role in characterizing groove pancreatitis. However, endoscopic fine-needle aspiration or biopsy should be considered in all cases to diagnose groove pancreatitis and exclude malignancy, which can have similar findings.


Subject(s)
Cysts , Pancreatic Neoplasms , Pancreatitis, Chronic , Humans , Male , Adult , Middle Aged , Female , Retrospective Studies , Pancreatitis, Chronic/diagnostic imaging , Tomography, X-Ray Computed , Biopsy, Fine-Needle , Pancreatic Neoplasms/diagnosis
17.
J Clin Med ; 12(11)2023 May 30.
Article in English | MEDLINE | ID: mdl-37297953

ABSTRACT

BACKGROUND: Endoscopic Ultrasound (EUS) is widely used for the diagnosis of bilio-pancreatic and gastrointestinal (GI) tract diseases, for the evaluation of subepithelial lesions, and for sampling of lymph nodes and solid masses located next to the GI tract. The role of Artificial Intelligence in healthcare in growing. This review aimed to provide an overview of the current state of AI in EUS from imaging to pathological diagnosis and training. METHODS: AI algorithms can assist in lesion detection and characterization in EUS by analyzing EUS images and identifying suspicious areas that may require further clinical evaluation or biopsy sampling. Deep learning techniques, such as convolutional neural networks (CNNs), have shown great potential for tumor identification and subepithelial lesion (SEL) evaluation by extracting important features from EUS images and using them to classify or segment the images. RESULTS: AI models with new features can increase the accuracy of diagnoses, provide faster diagnoses, identify subtle differences in disease presentation that may be missed by human eyes, and provide more information and insights into disease pathology. CONCLUSIONS: The integration of AI in EUS images and biopsies has the potential to improve the diagnostic accuracy, leading to better patient outcomes and to a reduction in repeated procedures in case of non-diagnostic biopsies.

19.
World J Gastrointest Endosc ; 15(4): 273-284, 2023 Apr 16.
Article in English | MEDLINE | ID: mdl-37138939

ABSTRACT

BACKGROUND: Solid pseudopapillary neoplasm (SPN) is an uncommon pathology of the pancreas with unpredictable malignant potential. Endoscopic ultrasound (EUS) assessment plays a vital role in lesion characterization and confirmation of the tissue diagnosis. However, there is a paucity of data regarding the imaging assessment of these lesions. AIM: To determine the characteristic EUS features of SPN and define its role in preoperative assessment. METHODS: This was an international, multicenter, retrospective, observational study of prospective cohorts from 7 large hepatopancreaticobiliary centers. All cases with postoperative histology of SPN were included in the study. Data collected included clinical, biochemical, histological and EUS characteristics. RESULTS: One hundred and six patients with the diagnosis of SPN were included. The mean age was 26 years (range 9 to 70 years), with female predominance (89.6%). The most frequent clinical presentation was abdominal pain (80/106; 75.5%). The mean diameter of the lesion was 53.7 mm (range 15 to 130 mm), with the slight predominant location in the head of the pancreas (44/106; 41.5%). The majority of lesions presented with solid imaging features (59/106; 55.7%) although 33.0% (35/106) had mixed solid/cystic characteristics and 11.3% (12/106) had cystic morphology. Calcification was observed in only 4 (3.8%) cases. Main pancreatic duct dilation was uncommon, evident in only 2 cases (1.9%), whilst common bile duct dilation was observed in 5 (11.3%) cases. One patient demonstrated a double duct sign at presentation. Elastography and Doppler evaluation demonstrated inconsistent appearances with no emergence of a predictable pattern. EUS guided biopsy was performed using three different types of needles: Fine needle aspiration (67/106; 63.2%), fine needle biopsy (37/106; 34.9%), and Sonar Trucut (2/106; 1.9%). The diagnosis was conclusive in 103 (97.2%) cases. Ninety-seven patients were treated surgically (91.5%) and the post-surgical SPN diagnosis was confirmed in all cases. During the 2-year follow-up period, no recurrence was observed. CONCLUSION: SPN presented primarily as a solid lesion on endosonographic assessment. The lesion tended to be located in the head or body of the pancreas. There was no consistent characteristic pattern apparent on either elastography or Doppler assessment. Similarly SPN did not frequently cause stricture of the pancreatic duct or common bile duct. Importantly, we confirmed that EUS-guided biopsy was an efficient and safe diagnostic tool. The needle type used does not appear to have a significant impact on the diagnostic yield. Overall SPN remains a challenging diagnosis based on EUS imaging with no pathognomonic features. EUS guided biopsy remains the gold standard in establishing the diagnosis.

20.
Int J Mol Sci ; 24(3)2023 Feb 03.
Article in English | MEDLINE | ID: mdl-36769342

ABSTRACT

Our previous research suggests an important regulatory role of CK2-mediated phosphorylation of enzymes involved in the thymidylate biosynthesis cycle, i.e., thymidylate synthase (TS), dihydrofolate reductase (DHFR), and serine hydroxymethyltransferase (SHMT). The aim of this study was to show whether silencing of the CK2α gene affects TS and DHFR expression in A-549 cells. Additionally, we attempted to identify the endogenous kinases that phosphorylate TS and DHFR in CCRF-CEM and A-549 cells. We used immunodetection, immunofluorescence/confocal analyses, reverse transcription-quantitative polymerase chain reaction (RT-qPCR), in-gel kinase assay, and mass spectrometry analysis. Our results demonstrate that silencing of the CK2α gene in lung adenocarcinoma cells significantly increases both TS and DHFR expression and affects their cellular distribution. Additionally, we show for the first time that both TS and DHFR are very likely phosphorylated by endogenous CK2 in two types of cancer cells, i.e., acute lymphoblastic leukaemia and lung adenocarcinoma. Moreover, our studies indicate that DHFR is phosphorylated intracellularly by CK2 to a greater extent in leukaemia cells than in lung adenocarcinoma cells. Interestingly, in-gel kinase assay results indicate that the CK2α' isoform was more active than the CK2α subunit. Our results confirm the previous studies concerning the physiological relevance of CK2-mediated phosphorylation of TS and DHFR.


Subject(s)
Adenocarcinoma of Lung , Tetrahydrofolate Dehydrogenase , Humans , Phosphorylation , Tetrahydrofolate Dehydrogenase/chemistry , Thymidylate Synthase/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...