Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Nutrients ; 16(11)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38892672

ABSTRACT

This article evaluates the reliability and consistency of nutrition- and supplementation-related advice for pregnant women provided by ten selected health-related Internet portals. The portals were chosen based on their perceived reliability and prominence in Google searches, with representation from both English and Polish language sources. The evaluation criteria included the adherence of the presented information to official recommendations and its evidence-based character based on specific items representing dietary aspects important in pregnancy. While the overall reliability was deemed acceptable, significant variations existed both among the portals and specific evaluated items. Notably, HealthLine, Medline Plus, and NCEZ emerged as the most evidence-based, while WebMD and Medycyna Praktyczna were identified as less reliable. Despite a number of issues, the analysed portals remain valuable sources of nutritional information for pregnant women, offering user-friendly accessibility superior to alternatives such as social media on the one hand and scientific articles on the other. Improved consistency and attention to detail, especially in relation to vitamin intake and supplementation, would improve the overall quality of health portals.


Subject(s)
Dietary Supplements , Humans , Female , Pregnancy , Reproducibility of Results , Internet , Pregnant Women , Patient Portals , Nutritional Status , Prenatal Care/methods , Maternal Nutritional Physiological Phenomena
2.
J Clin Med ; 13(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792339

ABSTRACT

Background: Male fertility is known to have been negatively influenced by the progress of civilization. Another condition whose incidence has been on the increase for the same reason is insulin resistance (IR). In addition, men increasingly often resign from the pursuit of active forms of leisure, preferring more sedentary ones. Considering these trends, this aim of this study was to investigate the relationships between lifestyle factors, insulin resistance, and male fertility in men with and without the condition. A further aim was to select those lifestyle factors that would make it possible to predict the level of male fertility, especially when IR is concerned. Methods: This study was performed in a group of 73 participants, divided into groups based on their insulin resistance status. Their physical activity, diet, perceived stress, sleep quality, libido level, and duration of sexual abstinence were assessed on the basis of a number of parameters, including indices proposed by the authors. In addition, relevant anthropometric measurements were taken and tests related to glucose metabolism and semen quality were carried out. On the basis of these data, statistical tests were performed to establish or disprove relationships between lifestyle choices and semen quality, as measured my sperm motility. Results: The results of this study highlighted the associations between a number of parameters, i.e., micronutrient and vitamin intake, diet quality, body composition, insulin resistance, and the duration of sexual abstinence, and semen quality, as measured by sperm motility. Significantly, the presence or absence of IR was linked to male fertility. A multivariate model was developed, incorporating parameters such as the Matsuda index, vitamin intake, and sexual abstinence duration, to predict motility scores. Conclusions: This study underscores the negative impact of modern civilization's lifestyle choices on male fertility. Notably, vitamin and mineral consumption, especially from antioxidant-rich diets like the Mediterranean diet, emerged as key modifiable factors affecting fertility. Routine diagnostics for insulin resistance in fertility-related interventions is recommended. This study also highlights the importance of considering sexual abstinence duration during semen collection for accurate diagnostic results. Future research should focus on validating the proposed multivariate model and exploring the effects of lifestyle modifications, particularly vitamin supplementation, on fertility outcomes in men, especially in the context of IR.

3.
Exp Brain Res ; 242(6): 1439-1453, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38652273

ABSTRACT

We explored unintentional drifts of finger forces during force production and matching task. Based on earlier studies, we predicted that force matching with the other hand would reduce or stop the force drift in instructed fingers while uninstructed (enslaved) fingers remain unaffected. Twelve young, healthy, right-handed participants performed two types of tasks with both hands (task hand and match hand). The task hand produced constant force at 20% of MVC level with the Index and Ring fingers pressing in parallel on strain gauge force sensors. The Middle finger force wasn't instructed, and its enslaved force was recorded. Visual feedback on the total force by the instructed fingers was either present throughout the trial or only during the first 5 s (no-feedback condition). The other hand matched the perceived force level of the task hand starting at either 4, 8, or 15 s from the trial initiation. No feedback was ever provided for the match hand force. After the visual feedback was removed, the task hand showed a consistent drift to lower magnitudes of total force. Contrary to our prediction, over all conditions, force matching caused a brief acceleration of force drift in the task hand, which then reached a plateau. There was no effect of matching on drifts in enslaved finger force. We interpret the force drifts within the theory of control with spatial referent coordinates as consequences of drifts in the command (referent coordinate) to the antagonist muscles. This command is not adequately incorporated into force perception.


Subject(s)
Fingers , Psychomotor Performance , Humans , Male , Female , Psychomotor Performance/physiology , Young Adult , Fingers/physiology , Adult , Feedback, Sensory/physiology , Hand Strength/physiology , Biomechanical Phenomena/physiology
4.
J Clin Med ; 12(19)2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37834919

ABSTRACT

Ovulatory infertility is a serious clinical problem whose direct causes are still largely unknown. In addition to pathologies that make it impossible for a couple to establish a pregnancy, there are a number of other factors that have a bearing on fertility, including lifestyle factors, and particularly diet. Although numerous studies have been performed linking such factors to ovulatory infertility, most of them lack the necessary clinical significance, instead focusing on observational data and suggesting or establishing associative relationships. This article consists of a literature review focusing on connections between lifestyle factors such as diet, physical exercise, oxidative stress, sleep, and supplementation, and ovulatory infertility. Special emphasis was given to issues such as obesity and insulin resistance and their mutual relationship with other factors linked to ovulatory infertility. In addition, based on the conclusions of the literature review, the authors have proposed a classification of relationships between ovulation disorders and lifestyle factors in ovulatory infertility within the framework of the WHO classification of ovulation disorders. Furthermore, areas that merit further research have been indicated as well as those that do not. WHO Group II disorders gained prominence in the results of the study as the number of links with lifestyle factors and ovulatory infertility found in the course of the review greatly exceeded those for Groups I and III. The data presented in the article show that the issues of proper diet and physical exercise are those that could benefit from robust clinical studies focused specifically on ovulation infertility, while studies concerning the relationship between oxidative stress, sleep, and supplementation and ovulatory infertility do not seem to be promising directions as far as clinical significance is concerned.

5.
Front Neurol ; 14: 1157335, 2023.
Article in English | MEDLINE | ID: mdl-37332988

ABSTRACT

Objective: The outcomes of physical therapy are commonly assessed with subjective scales and questionnaires. Hence, a continuous search to identify diagnostic tests that would facilitate objective assessment of symptom reduction in those patients with Achilles tendinopathy who undergo mechanotherapy. The main aim of this study was to evaluate and compare the effectiveness of shock wave and ultrasound treatments, using objective posturographic assessment during step-up and step-down initiation. Materials and methods: The patients with non-insertional Achilles tendinopathy and pain lasting for more than 3 months were randomly assigned to one of the experimental groups, i.e., radial shock wave therapy (RSWT), ultrasound therapy, or placebo ultrasound. All groups also received deep friction massage as the primary therapy. The transitional locomotor task was performed with the affected and unaffected limb in random order, on two force platforms under two conditions (step-up and step-down). The recording of center of foot pressure displacements was divided into three phases: quiet standing before step-up/step-down, transit, and quiet standing until measurement completion. Pre-intervention measurements were performed and then short-term follow-ups at weeks 1 and 6 post-therapy. Results: The three-way repeated measures ANOVA showed few statistically significant two-factor interactions between therapy type, time point of measurement and the type of the locomotor task. Significant increases in postural sway were observed in the entire study population throughout the follow-up period. Three-way ANOVAs revealed a group effect (shock wave vs. ultrasound) on almost all variables of the quiet standing phase prior to step-up/step-down initiation. Overall, postural stability before the step-up and step-down tasks appeared to be more efficient in patients who had undergone RSWT compared to the ultrasound group. Conclusion: Objective posturographic assessment during step-up and step-down initiation did not demonstrate therapeutic superiority of any of the three therapeutic interventions used in patients with non-insertional Achilles tendinopathy.Clinical Trial Registration: The trial was prospectively registered in the Australian and New Zealand Clinical Trials Registry (no. ACTRN12617000860369; registration date: 9.06.2017).

6.
J Hum Kinet ; 86: 51-61, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37181260

ABSTRACT

Efficient movement control and the mechanisms responsible for the sense of rhythm are still not fully understood. The purpose of this paper was to estimate the influence of fatigue on the sense of rhythm defined as specific order of movements and their rhythmic perception. It was examined in a holistic way, by analyzing both global and local aspects of the movement. Twenty adult participants (20.2 ± 0.4 years, ten females) took part in the experiment. The fatigue protocol was applied in four blocks, which consisted of 30-s consecutive jumping with 80% of maximal effort. Immediately after each fatigue block, the rhythm performance was evaluated in global and local tests. The global test was based on 45 continuous jumps and was divided into an assisted and an unassisted phase using the Optojump Next System. The local test was performed by bilateral tapping of lower limbs by means of the Vienna Test System. The hypothesis about the significant effect of fatigue on the sense of rhythm was falsified. In particular, we observed the lack of differences between global and local aspects of the movement. Moreover, female participants showed a better sense of rhythm than males. Regardless of the fatigue protocol, participants made larger errors with a lower movement frequency in local rhythmic tasks. The coefficient of variation showed that sex differences were only significant in the unassisted phase of the global rhythmic task. We suggest that movement variability metrics may provide additional information about the sense of rhythm, which should be explored more in future studies, not only dependent on fatigue.

7.
Entropy (Basel) ; 25(3)2023 Mar 18.
Article in English | MEDLINE | ID: mdl-36981415

ABSTRACT

The paper is dedicated to modeling electricity spot prices and pricing forward contracts on energy markets. The underlying dynamics of electricity spot prices is governed by a stochastic mean reverting diffusion with jumps having mixed-exponential distribution. Application of financial mathematics and stochastic methods enabled the derivation of the analytical formula for the forward contract's price in a crisp case. Since the model parameters' incertitude is considered, their fuzzy counterparts are introduced. Utilization of fuzzy arithmetic enabled deriving an analytical expression for the futures price and proposing a modified method for decision-making under uncertainty. Finally, numerical examples are analyzed to illustrate our pricing approach and the proposed financial decision-making method.

8.
Sci Rep ; 12(1): 20554, 2022 11 29.
Article in English | MEDLINE | ID: mdl-36446830

ABSTRACT

Creation of sub-epithelial voids within scarred vocal folds via ultrafast laser ablation may help in localization of injectable therapeutic biomaterials towards an improved treatment for vocal fold scarring. Several ultrafast laser surgery probes have been developed for precise ablation of surface tissues; however, these probes lack the tight beam focusing required for sub-surface ablation in highly scattering tissues such as vocal folds. Here, we present a miniaturized ultrafast laser surgery probe designed to perform sub-epithelial ablation in vocal folds. The requirement of high numerical aperture for sub-surface ablation, in addition to the small form factor and side-firing architecture required for clinical use, made for a challenging optical design. An Inhibited Coupling guiding Kagome hollow core photonic crystal fiber delivered micro-Joule level ultrashort pulses from a high repetition rate fiber laser towards a custom-built miniaturized objective, producing a 1/e2 focal beam radius of 1.12 ± 0.10 µm and covering a 46 × 46 µm2 scan area. The probe could deliver up to 3.8 µJ pulses to the tissue surface at 40% transmission efficiency through the entire system, providing significantly higher fluences at the focal plane than were required for sub-epithelial ablation. To assess surgical performance, we performed ablation studies on freshly excised porcine hemi-larynges and found that large area sub-epithelial voids could be created within vocal folds by mechanically translating the probe tip across the tissue surface using external stages. Finally, injection of a model biomaterial into a 1 × 2 mm2 void created 114 ± 30 µm beneath the vocal fold epithelium surface indicated improved localization when compared to direct injection into the tissue without a void, suggesting that our probe may be useful for pre-clinical evaluation of injectable therapeutic biomaterials for vocal fold scarring therapy. With future developments, the surgical system presented here may enable treatment of vocal fold scarring in a clinical setting.


Subject(s)
Laser Therapy , Vocal Cords , Animals , Swine , Vocal Cords/surgery , Cicatrix/surgery , Biocompatible Materials , Injections
9.
Biomed Opt Express ; 12(8): 4779-4794, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-34513224

ABSTRACT

We present a miniaturized ultrafast laser surgery probe with improved miniaturized optics to deliver higher peak powers and enable higher surgical speeds than previously possible. A custom-built miniaturized CaF2 objective showed no evidence of the strong multiphoton absorption observed in our previous ZnS-based probe, enabling higher laser power delivery to the tissue surface for ablation. A Kagome fiber delivered ultrashort pulses from a high repetition rate fiber laser to the objective, producing a focal beam radius of 1.96 µm and covering a 90×90 µm2 scan area. The probe delivered the maximum available fiber laser power, providing fluences >6 J/cm2 at the tissue surface at 53% transmission efficiency. We characterized the probe's performance through a parametric ablation study on bovine cortical bone and defined optimal operating parameters for surgery using an experimental- and simulation-based approach. The entire opto-mechanical system, enclosed within a 5-mm diameter housing with a 2.6-mm diameter probe tip, achieved material removal rates >0.1 mm3/min, however removal rates were ultimately limited by the available laser power. Towards a next generation surgery probe, we simulated maximum material removal rates when using a higher power fiber laser and found that removal rates >2 mm3/min could be attained through appropriate selection of laser surgery parameters. With future development, the device presented here can serve as a precise surgical tool with clinically viable speeds for delicate applications such as spinal decompression surgeries.

10.
Ann Biomed Eng ; 49(9): 2566-2578, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34244907

ABSTRACT

White blood cell (WBC) and neutrophil counts are important laboratory tests used by clinicians to assess a variety of conditions. However, current methods to measure WBC and neutrophil counts are difficult to perform at the point of care, being either cost or labor prohibitive. To meet this need, we developed the LeukoScope: a portable, imaging-based system to measure WBC and neutrophil counts from a drop of blood. Here, we present the performance of the LeukoScope in 136 pediatric and 164 neonatal subjects at a central hospital in Malawi. For pediatric patients, 95.4, 66.7, and 80.0% of samples with normal, low, and high WBC counts, respectively, were correctly identified, and 88.6, 100.0, and 89.3% of samples with normal, low, and high neutrophil counts, respectively, were correctly identified. Accuracy was lower overall for neonatal samples; 92.1, 64.3, and 26.7% of samples with normal, low, and high WBC counts, respectively, were correctly identified, and 73.2 and 78.6% of samples with normal and high neutrophil counts, respectively, were correctly identified. Results of this study show that the LeukoScope can help meet need for point-of-care measurement of WBC counts in pediatric patients and highlight the challenges of point-of-care assessment of WBC counts in neonatal patients.


Subject(s)
Leukocyte Count , Point-of-Care Systems , Adolescent , Algorithms , Child , Child, Preschool , Humans , Infant , Infant, Newborn , Leukocytes , Malawi
11.
Gait Posture ; 87: 170-176, 2021 06.
Article in English | MEDLINE | ID: mdl-33940308

ABSTRACT

INTRODUCTION: Although previous studies have contributed to our understanding of the effects of implementing the virtual reality as a rehabilitation tool in patients with Parkinson's disease (PD), additional research is needed to examine the effects of applying balance-based exergaming training on quantitative biomechanical measures of balance. RESEARCH QUESTION: To investigate the effects of balance-based conventional and exergaming training on posture parameters. METHODS: The study involved 24 patients with PD (Hoehn and Yahr stages II-III).Participants underwent twelve training sessions during the 4-week training period. The experimental group (n=12) was trained with a custom-made exergaming balance based training system, the control group (n=12) underwent a conventional balance training. All objective outcomes were measured before intervention and the day after completion of training program. Postural stability was assessed using the quiet standing test, dynamic balance was assessed using limits of stability (LOS) and functional balance (FBT) tests. RESULTS: After training, participants in both groups showed significantly better results in static balance performance. However, only exergaming training significantly improved LOS performance (higher values of Range of forward lean (p = 0.039, dz = 0.67) and leaning rate (p=0.007, dz=0.96). Also FBT test improved significantly only in experimental group (decrease in time to target hit (p=0.02, dz=0.76) and significant increase of average COP velocity (p=0.008, dz=0.93). CONCLUSION: This study found that exergaming training created for patients with PD enhanced static and dynamic balance whereas conventional balance training improved static balance. Posturography is sensitive enough to reveal differential effects of training for both groups. These findings support the inclusion of our exergaming training in the exercise program for participants with PD.


Subject(s)
Parkinson Disease , Biomechanical Phenomena , Exercise Therapy , Humans , Postural Balance , Posture , Video Games
12.
Article in English | MEDLINE | ID: mdl-33546350

ABSTRACT

Our aim was to observe, through objective testing using an assessment module incorporated in a new exergaming system, whether elderly people's static and functional balance is improved by a balance exergaming training program based on movements performed in everyday life. Thirteen healthy elderly women participated in 12 sessions of balance-based exergaming training (three times a week, 30 min per session). All objective outcomes, the quiet standing test, functional balance test (FBT), and limit of stability (LOS) test, were measured on three occasions: before intervention, after six training sessions, and after the completion of the four-week program. The results showed a significant improvement in LOS performance after the intervention. In FBT, participants exhibited a significant decrease (p < 0.01; Kendall's W = 0.5) in the average time to target hit after six trainings. The average center of pressure velocity increased after six and 12 sessions, however did not reach significance (p = 0.053); nevertheless the size of the effect was large (ηp2 = 0.22). The parameters of the quiet standing test were not significantly affected by the training. The results support the need for more definite and objective studies assessing exergaming for balance in elderly.


Subject(s)
Postural Balance , Video Games , Aged , Exercise Therapy , Female , Humans , Movement , Pilot Projects
13.
J Hum Kinet ; 76: 131-143, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33603930

ABSTRACT

The uncontrolled manifold hypothesis is a method used to quantify motor synergies, defined as a specific central nervous system organization that maintains the task-specific stability of motor actions. The UCM allows for inter-trial variance analysis between consecutive trials. However, despite the large body of literature within this framework, there is no report on the number of movement repetitions required for reliable results. Based on the hypothetical hierarchical control of motor synergies, this study aims to determine the minimum number of trials necessary to achieve a good to excellent level of reliability. Thirteen young, healthy participants performed fifteen bilateral isometric contractions of elbow flexion when visual feedback was provided. The force and electromyography data were recorded to investigate synergies at different levels of hierarchical control. The intraclass correlation coefficient was used to determine the reliability of the variance indices. Based on the obtained results, at least twelve trials are required to analyze the inter-trial variance in both force and muscle synergies within the UCM framework.

14.
J Biomech ; 105: 109773, 2020 05 22.
Article in English | MEDLINE | ID: mdl-32279933

ABSTRACT

Radial shock wave therapy (RSWT) has been recommended as an appropriate, safe and effective method in the treatment of chronic plantar fasciitis (PF). The main purpose of this study was to examine how RSWT affects gait parameters. This study included 23 patients with unilateral, chronic PF. RSWT were administered in 5 interventions, during a consecutive 3-week period. Objective kinetic (force distribution under the forefoot, midfoot, rearfoot) and spatiotemporal parameters (cadence, step length, stance phase duration) during treadmill walking at, preferred" speed were evaluated on. 4 sessions: before therapy, immediately after (primary endpoint), 3 and 6 weeks after therapy. The mean reduction in the reported pain when taking first steps in the morning from baseline to the primary endpoint, 3- and 6-weeks post procedure was 42.7%, 50.1% and 66.9% respectively. Similar reduction was seen in the reported pain during walking. After the therapy during gait at the preferred speed patients had a significantly higher force beneath the rearfoot and forefoot of both limbs. Force beneath the midfoot was not significantly affected by treatment. The step length in both limbs increased by 3.3-3.6 cm after RSWT. After the therapy stance phase duration in symptomatic foot was longer by 7% and it slightly decreased until POST-6wk. Similar changes were seen in an asymptomatic limb. The spatiotemporal and kinetic results indicate that RSWT therapy induces changes in patient's gait structure and alter regional loading in the affected foot.


Subject(s)
Extracorporeal Shockwave Therapy , Fasciitis, Plantar , Fasciitis, Plantar/therapy , Foot , Gait , Humans , Walking
15.
Transl Vis Sci Technol ; 8(3): 44, 2019 May.
Article in English | MEDLINE | ID: mdl-31259089

ABSTRACT

PURPOSE: Retinal angiography evaluates retinal and choroidal perfusion and vascular integrity and is used to manage many ophthalmic diseases, such as age-related macular degeneration. The most common method, fluorescein angiography (FA), is invasive and can lead to untoward effects. As an emerging replacement, noninvasive OCT angiography (OCTA) is used regularly as a dye-free substitute with superior resolution and additional depth-sectioning abilities; however, general trends in FA as signified by varying intensity in images are not always reproducible in the fine structural detail in an OCTA image stack because of the source of their respective signals, OCT speckle decorrelation versus fluorescein emission. METHODS: We present a noninvasive/dye-free analog to angiography imaging using retinal hyperspectral imaging with a nonscanning spectral imager, the image mapping spectrometer (IMS), to reproduce perfusion-related data based on the abundance of oxyhemoglobin (HbO2) in the retina. With a new unmixing procedure of the IMS-acquired spectral data cubes (350 × 350 × 43), we produced noninvasive HbO2 maps unmixed from reflectance spectra. RESULTS: Here, we present 15 HbO2 maps from seven healthy and eight diseased retinas and compare these maps with corresponding FA and OCTA results with a discussion of each technique. CONCLUSIONS: Our maps showed visual agreement with hypo- and hyperfluorescence trends in venous phase FA images, suggesting that our method provides a new use for hyperspectral imaging as a noninvasive angiography-analog technique and as a complementary technique to OCTA. TRANSLATIONAL RELEVANCE: The application of hyperspectral imaging and spectral analysis can potentially improve/broaden retinal disease screening and enable a noninvasive technique, which complements OCTA.

16.
Opt Express ; 27(11): 15701-15725, 2019 May 27.
Article in English | MEDLINE | ID: mdl-31163763

ABSTRACT

A fiber-based snapshot imaging spectrometer was developed with a maximum of 31853 (~188 x 170) spatial sampling and 61 spectral channels in the 450nm-750nm range. A compact, custom-fabricated fiber bundle was used to sample the object image at the input and create void spaces between rows at the output for dispersion. The bundle was built using multicore 6x6 fiber block ribbons. To avoid overlap between the cores in the direction of dispersion, we selected a subset of cores using two alternative approaches; a lenslet array and a photomask. To calibrate the >30000 spatial samples of the system, a rapid spatial calibration method was developed based on phase-shifting interferometry (PSI). System crosstalk and spectral resolution were also characterized. Preliminary hyperspectral imaging results of the Rice University campus landscape, obtained with the spectrometer, are presented to demonstrate the system's spectral imaging capability for distant scenes. The spectrum of different plant species with different health conditions, obtained with the spectrometer, was in accordance with reference instrument measurements. We also imaged Houston traffic to demonstrate the system's snapshot hyperspectral imaging capability. Potential applications of the system include terrestrial monitoring, land use, air pollution, water resources, and lightning spectroscopy. The fiber-based system design potentially allows tuning between spatial and spectral sampling to meet specific imaging requirements.

17.
PLoS One ; 14(4): e0214090, 2019.
Article in English | MEDLINE | ID: mdl-30970020

ABSTRACT

At the primary care setting, where there are often no or minimal laboratories, examinations often consist of self-testing and rapid diagnostics. Because of this, medical devices must be simple, robust, and easy to operate. To address these concerns, an alternate fluorescence microscope design uses ultraviolet (UV) excitation, since fluorescent dyes that are excitable in the visible region are also excitable by UV. This may allow for the removal of typical excitation, emission, and dichroic filters as optical components absorb UV wavelengths and UV is not detected by silicon based detectors. Additionally, UV has a very low penetration into samples, which may allow for controlling the depth of excitation, and thus the imaging volume. Based on these ideas, we developed a simple fluorescence microscope built completely from off-the-shelf components that uses UV to image fluorescently stained samples. The simple opto-mechanical design of the system may allow it to be more compact and easy to use, as well as decrease the overall cost of the diagnostic device. For biological validation, we imaged whole blood stained with acridine orange and performed a two-part white blood cell differential count.


Subject(s)
Leukocyte Count , Microscopy, Fluorescence/methods , Microscopy, Ultraviolet/methods , Point-of-Care Systems , Fluorescent Dyes/chemistry , Humans , Leukocytes/ultrastructure , Optical Devices
18.
Biomed Opt Express ; 10(3): 1432-1445, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30891357

ABSTRACT

Fiber bundle endomicroscopy techniques have been used for numerous minimally invasive imaging applications. However, these techniques may provide limited spatial sampling due to the limited number of imaging cores inside the fiber bundle. Here, we present a custom-fabricated miniature objective that can be coupled to a fiber bundle and can overcome the fiber bundle's sampling threshold by utilizing the spectral encoding concept. The objective has an NA of 0.3 and an outer diameter of 2.4 mm, and can yield a maximum spatial resolution of 2 µm. The objective has been validated against a USAF resolution target and ex vivo tissue samples, and as a result yielded images with higher resolution and more details after the spectral encoding concept was employed.

19.
Opt Express ; 27(2): 1597-1612, 2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30696224

ABSTRACT

A high performance, snapshot Image Mapping Spectrometer was developed that provides fast image acquisition (100 Hz) of 16 bit hyperspectral data cubes (210x210x46) over a spectral range of 515-842 nm. Essential details of the opto-mechanical design are presented. Spectral accuracy, precision, and image reconstruction metrics such as resolution are discussed. Fluorescently stained cell samples were used to directly compare the data obtained using newly developed and the reference image mapping spectrometer. Additional experimental results are provided to demonstrate the abilities of the new spectrometer to acquire highly-resolved, motion-artifact-free hyperspectral images at high temporal sampling rates.

20.
RSC Adv ; 9(47): 27324-27333, 2019 Aug 29.
Article in English | MEDLINE | ID: mdl-35529242

ABSTRACT

A white blood cell (WBC) count with partial differential is an important clinical laboratory test. However, current methods to perform a WBC count and differential are difficult to use at the point of care or too expensive for use in low-resource settings. To meet this need, we developed the LeukoScope: a low-cost system to measure a WBC and neutrophil count from a single drop of blood at the point of care. The LeukoScope is battery powered and has a sample-to-answer time of <5 minutes. A drop of blood from a finger stick is added to a LeukoScope sample cartridge where pre-dried acridine orange fluorescently stains WBCs. The cartridge is then inserted into the LeukoScope reader where a portable fluorescence microscope captures a color image of the sample, which is analyzed to report results to the user. The LeukoScope system was tested at the point of care using fingerprick samples collected from 105 general oncology patients in Houston, TX. Performance of the LeukoScope was compared to that of a HemoCue WBC DIFF performed using the same fingerprick sample; clinical laboratory analysis of a venous blood draw was used as the gold standard in all cases. Bland-Altman analysis showed that the LeukoScope and HemoCue WBC DIFF had similar accuracy for measurement of WBC and neutrophil counts as compared to the gold standard. Seven out of eight patients with abnormal WBC count values were correctly identified using the LeukoScope, while six out of eight were correctly identified using the HemoCue WBC DIFF. Five out of six patients with abnormal neutrophil counts were correctly identified using the LeukoScope, while six of six were correctly identified using the HemoCue WBC DIFF.

SELECTION OF CITATIONS
SEARCH DETAIL
...