1.
Materials (Basel) ; 17(2)2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38255538

ABSTRACT

The experimental quantification of retention factors related to the post-fire strength as well as the post-fire ductility of intentionally selected stainless steel grades applied in construction is the objective of the research presented here. These steel grades are characterized by a two-phase austenitic-ferritic microstructure of the duplex type. In this context, two mutually corresponding chromium-nickel-molybdenum steel grades are subjected to analysis, namely X2CrNiMoN22-5-3 steel belonging to the standard duplex group (DSS 22% Cr) and X2CrMnNiN21-5-1 steel belonging to the lean duplex group (LDSS). The similarities and differences in the mechanical properties exhibited by these steel grades after effective cooling, following more or less prolonged simulated fire action conforming to several development scenarios, are identified and indicated. The resistance of a given steel grade to permanent structural changes induced by the heating program proved to be the critical factor determining these properties and resulting in many cases in increased susceptibility to brittle fracture. The results obtained experimentally seem to confirm the quantitative estimates of post-fire retention factors forecast by Molkens and his team, specified for the steels exhibiting a duplex-type structure and tested by us. However, several of these estimates might be considered somewhat risky. Nevertheless, our results do not confirm the significant post-fire strengthening of steel grades belonging to the LDSS group following prior heating at a sufficiently high temperature, as reported earlier by Huang Yuner and B. Young.

2.
Materials (Basel) ; 16(8)2023 Apr 21.
Article in English | MEDLINE | ID: mdl-37110117

ABSTRACT

The results of experimental research on forecasting post-fire resistance to brittle failure of selected steel grades used in construction are presented and discussed in this paper. The conclusions are based on detailed analysis of fracture surfaces obtained in instrumented Charpy tests. It has been shown that the relationships formulated based on these tests agree well with conclusions drawn based on precise analysis of appropriate F-s curves. Furthermore, other relationships between lateral expansion LE and energy Wt required to break the sample constitute an additional verification in both qualitative and quantitative terms. These relationships are accompanied here by values of the SFA(n) parameter, which are different, depending on the character of the fracture. Steel grades differing in microstructure have been selected for the detailed analysis, including: S355J2+N-representative for materials of ferritic-pearlitic structure, and also stainless steels such as X20Cr13-of martensitic structure, X6CrNiTi18-10-of austenitic structure and X2CrNiMoN22-5-3 duplex steel-of austenitic-ferritic structure.

3.
Materials (Basel) ; 14(14)2021 Jul 14.
Article in English | MEDLINE | ID: mdl-34300840

ABSTRACT

The change in the value of the breaking energy is discussed here for selected steel grades used in building structures after subjecting the samples made of them to episodes of heating in the steady-state heating regime and then cooling in simulated fire conditions. These changes were recorded based on the instrumented Charpy impact tests, in relation to the material initial state. The S355J2+N, 1H18N9T steels and also X2CrNiMoN22-5-3 duplex steel were selected for detailed analysis. The fire conditions were modelled experimentally by heating the samples and then keeping them for a specified time at a constant temperature of: 600 °C (first series) and 800 °C (second series), respectively. Two alternative cooling variants were investigated in the experiment: slow cooling of the samples in the furnace, simulating the natural fire progress, without any external extinguishing action and cooling in water mist simulating an extinguishing action by a fire brigade. The temperature of the tested samples was set at the level of -20 °C and alternatively at the level of +20 °C. The conducted analysis is aimed at assessing the risk of sudden, catastrophic fracture of load-bearing structure made of steel degraded as a result of a fire that occurred previously with different development scenarios.