Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Pediatr Otorhinolaryngol ; 79(2): 119-26, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25532671

ABSTRACT

BACKGROUND: Acquired subglottic stenosis (SGS) most commonly results from prolonged endotracheal intubation and is a diagnostic challenge in the intubated child. At present, no imaging modality allows for in vivo characterization of subglottic microanatomy to identify early signs of acquired SGS while the child remains intubated. Fourier domain optical coherence tomography (FD-OCT) is a minimally invasive, light-based imaging modality which provides high resolution, three dimensional (3D) cross-sectional images of biological tissue. We used long-range FD-OCT to image the subglottis in intubated pediatric patients undergoing minor head and neck surgical procedures in the operating room. METHODS: A long-range FD-OCT system and rotary optical probes (1.2mm and 0.7mm outer diameters) were constructed. Forty-six pediatric patients (ages 2-16 years) undergoing minor upper airway surgery (e.g., tonsillectomy and adenoidectomy) were selected for intraoperative, trans-endotracheal tube FD-OCT of the subglottis. Images were analyzed for anatomical landmarks and subepithelial histology. Volumetric image sets were rendered into virtual 3D airway models in Mimics software. RESULTS: FD-OCT was performed on 46 patients (ages 2-16 years) with no complications. Gross airway contour was visible on all 46 data sets. Twenty (43%) high-quality data sets clearly demonstrated airway anatomy (e.g., tracheal rings, cricoid and vocal folds) and layered microanatomy of the mucosa (e.g., epithelium, basement membrane and lamina propria). The remaining 26 data sets were discarded due to artifact, high signal-to-noise ratio or missing data. 3D airway models were allowed for user-controlled manipulation and multiplanar airway slicing (e.g., sagittal, coronal) for visualization of OCT data at multiple anatomic levels simultaneously. CONCLUSIONS: Long-range FD-OCT produces high-resolution, 3D volumetric images of the pediatric subglottis. This technology offers a safe and practical means for in vivo evaluation of lower airway microanatomy in intubated pediatric patients. Ultimately, FD-OCT may be applied to serial monitoring of the neonatal subglottis in long-term intubated infants at risk for acquired SGS.


Subject(s)
Glottis/pathology , Imaging, Three-Dimensional , Laryngostenosis/diagnosis , Tomography, Optical Coherence , Adolescent , Child , Child, Preschool , Feasibility Studies , Female , Humans , Intubation, Intratracheal/adverse effects , Laryngostenosis/etiology , Laryngostenosis/surgery , Male , Signal-To-Noise Ratio
2.
World J Emerg Surg ; 6: 11, 2011 Apr 08.
Article in English | MEDLINE | ID: mdl-21477304

ABSTRACT

BACKGROUND: Extracranial traumatic cerebrovascular injury (TCVI) is present in 1-3% of all blunt force trauma patients. Although options for the management of patients with these lesions include anticoagulation, antiplatelet agents, and endovascular treatment, the optimal management strategy for patients with these lesions is not yet established. OBJECTIVE: Multidisciplinary survey of clinicians about current management of TCVI. METHODS: A six-item multiple-choice survey was sent by electronic mail to a total of 11,784 neurosurgeons, trauma surgeons, stroke neurologists, and interventional radiologists. The survey included questions about their choice of imaging, medical management, and the use of endovascular techniques. Survey responses were analyzed according to stated specialty. RESULTS: Seven hundred eighty-five (6.7%) responses were received. Overall, a total of 325 (42.8%) respondents favored anticoagulation (heparin and/or warfarin), 247 (32.5%) favored antiplatelet drugs, 130 (17.1%) preferred both anticoagulation and antiplatelet drugs, and 57 (7.5%) preferred stenting and/or embolization. Anticoagulation was the most commonly preferred treatment among vascular surgeons (56.9%), neurologists (50.2%) and neurosurgeons (40.7%), whereas antiplatelet agents were the most common preferred treatment among trauma surgeons (41.5%). Overall, 158 (20.7%) of respondents recommended treatment of asymptomatic dissections and traumatic aneurysms, 211 (27.7%) did not recommend it, and 39.4% recommended endovascular treatment only if there is worsening of the lesion on follow-up imaging. CONCLUSIONS: These data demonstrate the wide variability of physicians' management of traumatic cerebrovascular injury, both on an individual basis, and between specialties. These findings underscore the need for multicenter, randomized trials in this field.

3.
Comput Aided Surg ; 13(3): 139-47, 2008 May.
Article in English | MEDLINE | ID: mdl-18432413

ABSTRACT

OBJECTIVE: To demonstrate the feasibility of an integer programming model to assist in pre-operative planning for open reduction and internal fixation of a distal humerus fracture. MATERIALS AND METHODS: We describe an integer programming model based on the objective of maximizing the reward for screws placed while satisfying the requirements for sound internal fixation. The model maximizes the number of bicortical screws placed while avoiding screw collision and favoring screws of greater length that cross multiple fracture planes. RESULTS: The model was tested on three types of total articular fractures of the distal humerus. Solutions were generated using 5, 9, 21 and 33 possible screw orientations per hole. Solutions generated using 33 possible screw orientations per hole and five screw lengths resulted in the most clinically relevant fixation plan and required the calculation of 1,191,975 pairs of screws that resulted in collision. At this level of complexity, the pre-processor took 104 seconds to generate the constraints for the solver, and a solution was generated in under one minute in all three cases. CONCLUSION: Despite the large size of this problem, it can be solved in a reasonable amount of time, making use of the model practical in pre-surgical planning.


Subject(s)
Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Humerus/surgery , Models, Theoretical , Preoperative Care , Surgery, Computer-Assisted/instrumentation , Feasibility Studies , Humans , Humerus/injuries , Orthopedic Procedures/instrumentation , Software Design
SELECTION OF CITATIONS
SEARCH DETAIL
...