Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 28(11): 15770-15782, 2020 May 25.
Article in English | MEDLINE | ID: mdl-32549414

ABSTRACT

We report on a new X-ray imaging method, which generalizes Bragg ptychography to 3D mapping of embedded crystalline volumes within thick specimens. The sample is probed by a pencil X-ray beam. The diffracted beam is magnified by an objective and passes through a slit in the image plane to be monitored by a 2D detector in the far-field of the image plane. The dimensions of the incoming beam and the slit opening define a confocal Bragg volume. Scanning the sample with respect to this probe volume, an iterative oversampling routine is used to reconstruct the shape and projected displacement field of extended internal volumes. This routine takes into account the pupil function and known aberrations of the lens. We demonstrate the method by a numerical study of a 3.5 µm grain comprising a wall of edge dislocations. With a probe volume of ∼0.12 µm3 and a compound refractive lens with a numerical aperture of 0.49×10-3 as the objective, the dislocations are fully resolved with a displacement sensitivity of ∼10 pm. The spatial resolution is 26×27×123 nm3 (rms), with the poor resolution along the optical axis being limited by the probe size. With a four times larger numerical aperture, the resolution becomes 16×8×123 nm3 (rms). The lens aberrations are found to be not critical.

2.
Opt Express ; 26(18): 23411-23425, 2018 Sep 03.
Article in English | MEDLINE | ID: mdl-30184842

ABSTRACT

Bragg coherent diffraction imaging (BCDI) is a powerful X-ray imaging technique for crystalline materials, providing high resolution maps of structure and strain. The technique is typically used to study a small isolated object, and is in general not compatible with a bulk polycrystalline sample, due to overlap of diffraction signals from various crystalline elements. In this paper, we present an imaging method for bulk samples, based on the use of a coherent source. The diffracted X-ray beam from a grain or domain of choice is magnified by an objective before being monitored by a 2D detector in the far field. The reconstruction principle is similar to the case of BCDI, while taking the magnification and pupil function into account. The concept is demonstrated using numerical simulations and reconstructions. We find that by using an object-lens distance shorter than the focal length, the numerical aperture is larger than in a traditional imaging geometry, and at the same time the setup is insensitive to small phase errors by lens imperfections. According to our simulations, we expect to be able to achieve a spatial resolution smaller than 20 nm when using the objective lens in this configuration.

3.
J Synchrotron Radiat ; 25(Pt 3): 717-728, 2018 May 01.
Article in English | MEDLINE | ID: mdl-29714181

ABSTRACT

The fractional Fourier transform (FrFT) is introduced as a tool for numerical simulations of X-ray wavefront propagation. By removing the strict sampling requirements encountered in typical Fourier optics, simulations using the FrFT can be carried out with much decreased detail, allowing, for example, on-line simulation during experiments. Moreover, the additive index property of the FrFT allows the propagation through multiple optical components to be simulated in a single step, which is particularly useful for compound refractive lenses (CRLs). It is shown that it is possible to model the attenuation from the entire CRL using one or two effective apertures without loss of accuracy, greatly accelerating simulations involving CRLs. To demonstrate the applicability and accuracy of the FrFT, the imaging resolution of a CRL-based imaging system is estimated, and the FrFT approach is shown to be significantly more precise than comparable approaches using geometrical optics. Secondly, it is shown that extensive FrFT simulations of complex systems involving coherence and/or non-monochromatic sources can be carried out in minutes. Specifically, the chromatic aberrations as a function of source bandwidth are estimated, and it is found that the geometric optics greatly overestimates the aberration for energy bandwidths of around 1%.

SELECTION OF CITATIONS
SEARCH DETAIL
...