1.
J Appl Crystallogr ; 55(Pt 4): 944-952, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-35974719

ABSTRACT

Liquid sample delivery systems are used extensively for serial femtosecond crystallography at X-ray free-electron lasers (XFELs). However, misalignment of the liquid jet and the XFEL beam leads to the X-rays either partially or completely missing the sample, resulting in sample wastage and a loss of experiment time. Implemented here is an algorithm to analyse optical images using machine vision to determine whether there is overlap of the X-ray beam and liquid jet. The long-term goal is to use the output from this algorithm to implement an automated feedback mechanism to maintain constant alignment of the X-ray beam and liquid jet. The key elements of this jet alignment algorithm are discussed and its performance is characterized by comparing the results with a manual analysis of the optical image data. The success rate of the algorithm for correctly identifying hits is quantified via a similarity metric, the Dice coefficient. In total four different nozzle designs were used in this study, yielding an overall Dice coefficient of 0.98.

2.
J Med Imaging (Bellingham) ; 8(5): 052108, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34268442

ABSTRACT

Purpose: Breast cancer is the most common cancer in women in developing and developed countries and is responsible for 15% of women's cancer deaths worldwide. Conventional absorption-based breast imaging techniques lack sufficient contrast for comprehensive diagnosis. Propagation-based phase-contrast computed tomography (PB-CT) is a developing technique that exploits a more contrast-sensitive property of x-rays: x-ray refraction. X-ray absorption, refraction, and contrast-to-noise in the corresponding images depend on the x-ray energy used, for the same/fixed radiation dose. The aim of this paper is to explore the relationship between x-ray energy and radiological image quality in PB-CT imaging. Approach: Thirty-nine mastectomy samples were scanned at the imaging and medical beamline at the Australian Synchrotron. Samples were scanned at various x-ray energies of 26, 28, 30, 32, 34, and 60 keV using a Hamamatsu Flat Panel detector at the same object-to-detector distance of 6 m and mean glandular dose of 4 mGy. A total of 132 image sets were produced for analysis. Seven observers rated PB-CT images against absorption-based CT (AB-CT) images of the same samples on a five-point scale. A visual grading characteristics (VGC) study was used to determine the difference in image quality. Results: PB-CT images produced at 28, 30, 32, and 34 keV x-ray energies demonstrated statistically significant higher image quality than reference AB-CT images. The optimum x-ray energy, 30 keV, displayed the largest area under the curve ( AUC VGC ) of 0.754 ( p = 0.009 ). This was followed by 32 keV ( AUC VGC = 0.731 , p ≤ 0.001 ), 34 keV ( AUC VGC = 0.723 , p ≤ 0.001 ), and 28 keV ( AUC VGC = 0.654 , p = 0.015 ). Conclusions: An optimum energy range (around 30 keV) in the PB-CT technique allows for higher image quality at a dose comparable to conventional mammographic techniques. This results in improved radiological image quality compared with conventional techniques, which may ultimately lead to higher diagnostic efficacy and a reduction in breast cancer mortalities.

3.
Acad Radiol ; 28(1): e20-e26, 2021 01.
Article in English | MEDLINE | ID: mdl-32035759

ABSTRACT

RATIONALE AND OBJECTIVES: Propagation-based phase-contrast CT (PB-CT) is an advanced X-ray imaging technology that exploits both refraction and absorption of the transmitted X-ray beam. This study was aimed at optimizing the experimental conditions of PB-CT for breast cancer imaging and examined its performance relative to conventional absorption-based CT (AB-CT) in terms of image quality and radiation dose. MATERIALS AND METHODS: Surgically excised breast mastectomy specimens (n = 12) were scanned using both PB-CT and AB-CT techniques under varying imaging conditions. To evaluate the radiological image quality, visual grading characteristics (VGC) analysis was used in which 11 breast specialist radiologists compared the overall image quality of PB-CT images with respect to the corresponding AB-CT images. The area under the VGC curve was calculated to measure the differences between PB-CT and AB-CT images. RESULTS: The highest radiological quality was obtained for PB-CT images using a 32 keV energy X-ray beam and by applying the Homogeneous Transport of Intensity Equation phase retrieval with the value of its parameter γ set to one-half of the theoretically optimal value for the given materials. Using these optimized conditions, the image quality of PB-CT images obtained at 4 mGy and 2 mGy mean glandular dose was significantly higher than AB-CT images at 4 mGy (AUCVGC = 0.901, p = 0.001 and AUCVGC = 0.819, p = 0.011, respectively). CONCLUSION: PB-CT achieves a higher radiological image quality compared to AB-CT even at a considerably lower mean glandular dose. Successful translation of the PB-CT technique for breast cancer imaging can potentially result in improved breast cancer diagnosis.


Subject(s)
Breast Neoplasms , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Humans , Mastectomy , Radiation Dosage , Tomography, X-Ray Computed
4.
J Vis Exp ; (126)2017 08 22.
Article in English | MEDLINE | ID: mdl-28872125

ABSTRACT

The precise details of the interaction of intense X-ray pulses with matter are a topic of intense interest to researchers attempting to interpret the results of femtosecond X-ray free electron laser (XFEL) experiments. An increasing number of experimental observations have shown that although nuclear motion can be negligible, given a short enough incident pulse duration, electronic motion cannot be ignored. The current and widely accepted models assume that although electrons undergo dynamics driven by interaction with the pulse, their motion could largely be considered 'random'. This would then allow the supposedly incoherent contribution from the electronic motion to be treated as a continuous background signal and thus ignored. The original aim of our experiment was to precisely measure the change in intensity of individual Bragg peaks, due to X-ray induced electronic damage in a model system, crystalline C60. Contrary to this expectation, we observed that at the highest X-ray intensities, the electron dynamics in C60 were in fact highly correlated, and over sufficiently long distances that the positions of the Bragg reflections are significantly altered. This paper describes in detail the methods and protocols used for these experiments, which were conducted both at the Linac Coherent Light Source (LCLS) and the Australian Synchrotron (AS) as well as the crystallographic approaches used to analyse the data.


Subject(s)
Fullerenes/metabolism , Nanoparticles/metabolism , X-Ray Diffraction/methods , Models, Biological
5.
Sci Adv ; 2(9): e1601186, 2016 09.
Article in English | MEDLINE | ID: mdl-27626076

ABSTRACT

X-ray free-electron lasers (XFELs) deliver x-ray pulses with a coherent flux that is approximately eight orders of magnitude greater than that available from a modern third-generation synchrotron source. The power density of an XFEL pulse may be so high that it can modify the electronic properties of a sample on a femtosecond time scale. Exploration of the interaction of intense coherent x-ray pulses and matter is both of intrinsic scientific interest and of critical importance to the interpretation of experiments that probe the structures of materials using high-brightness femtosecond XFEL pulses. We report observations of the diffraction of extremely intense 32-fs nanofocused x-ray pulses by a powder sample of crystalline C60. We find that the diffraction pattern at the highest available incident power significantly differs from the one obtained using either third-generation synchrotron sources or XFEL sources operating at low output power and does not correspond to the diffraction pattern expected from any known phase of crystalline C60. We interpret these data as evidence of a long-range, coherent dynamic electronic distortion that is driven by the interaction of the periodic array of C60 molecular targets with intense x-ray pulses of femtosecond duration.


Subject(s)
Fullerenes/chemistry , Nanoparticles/chemistry , X-Ray Diffraction , Crystallography, X-Ray , Electrons , Lasers , Light , Synchrotrons , X-Rays
6.
Sci Rep ; 4: 6796, 2014 Oct 28.
Article in English | MEDLINE | ID: mdl-25348877

ABSTRACT

Isolating compositional information in biological X-ray imaging can be problematic as such information is conflated with thickness and density variations when viewing in projection through a sample. We demonstrate an effective method for identifying variations in material composition by simultaneously using the quantitative phase and magnitude images provided through soft X-ray ptychography. Using this approach we show significantly increased contrast and improved reliability of the identification of intracellular features from uncharacterised samples. While demonstrated for X-ray ptychography, this method is immediately applicable to electron and optical microscopy methods where the complex transmission function of the sample is recovered.


Subject(s)
Cell Tracking/methods , Microscopy/methods , Molecular Imaging , Animals , Contrast Media/chemistry , Electrons , Fibroblasts/ultrastructure , Mice , X-Rays
7.
Ultramicroscopy ; 143: 88-92, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24209602

ABSTRACT

Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application.


Subject(s)
Diagnostic Imaging/methods , Malaria, Falciparum/diagnosis , Parasites/ultrastructure , Plasmodium falciparum/ultrastructure , X-Ray Diffraction/methods , Animals , Erythrocytes/parasitology , Image Processing, Computer-Assisted/methods , Microscopy, Electron/methods , Optical Imaging/methods , Sensitivity and Specificity
8.
Sci Rep ; 3: 2288, 2013.
Article in English | MEDLINE | ID: mdl-23887204

ABSTRACT

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.


Subject(s)
Single-Cell Analysis/methods , Tomography, X-Ray Computed/methods , Erythrocytes/cytology , Erythrocytes/parasitology , Humans
9.
Bone ; 52(1): 126-32, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22995461

ABSTRACT

In recent years there has been growing interest in the spatial properties of osteocytes (including density and morphology) and how these potentially relate to adaptation, disease and aging. This interest has, in part, arisen from the availability of increasingly high-resolution 3D imaging modalities such as synchrotron radiation (SR) micro-CT. As resolution increases, field of view generally decreases. Thus, while increasingly detailed spatial information is obtained, it is unclear how representative this information is of the skeleton or even the isolated bone. The purpose of this research was to describe the variation in osteocyte lacunar density, morphology and orientation within the femur from a healthy young male human. Multiple anterior, posterior, medial and lateral blocks (2 mm × 2 mm) were prepared from the proximal femoral shaft and SR micro-CT imaged at the Advanced Photon Source. Average lacunar densities (± standard deviation) from the anterior, posterior, medial and lateral regions were 27,169 ± 1935, 26,3643 ± 1262, 37,521 ± 6416 and 33,972 ± 2513 lacunae per mm(3) of bone tissue, respectively. These values were significantly different between the medial and both the anterior and posterior regions (p<0.05). The density of the combined anterior and posterior regions was also significantly lower (p=0.001) than the density of the combined medial and lateral regions. Although no difference was found in predominant orientation, shape differences were found; with the combined anterior and posterior regions having more elongated (p=0.004) and flattened (p=0.045) lacunae, than those of the medial and lateral regions. This study reveals variation in osteocyte lacunar density and morphology within the cross-section of a single bone and that this variation can be considerable (up to 30% difference in density between regions). The underlying functional significance of the observed variation in lacunar density likely relates to localized variations in loading conditions as the pattern corresponds well with mechanical axes. Lower density and more elongate shapes being associated with the antero-posterior oriented neutral axis. Our findings demonstrate that the functional and pathological interpretations that are increasingly being drawn from high resolution imaging of osteocyte lacunae need to be better situated within the broader context of normal variation, including that which occurs even within a single skeletal element.


Subject(s)
Femur/cytology , Osteocytes/cytology , Tomography, X-Ray Computed/methods , Adult , Femur/diagnostic imaging , Humans , Male , Young Adult
10.
Opt Express ; 20(24): 26778-85, 2012 Nov 19.
Article in English | MEDLINE | ID: mdl-23187532

ABSTRACT

We have applied Fresnel Coherent Diffractive Imaging (FCDI) to image an intact pollen grain from Convallaria majalis. This approach allows us to resolve internal structures without the requirement to chemically treat or slice the sample into thin sections. Coherent X-ray diffraction data from this pollen grain-composed of a hologram and higher resolution scattering information-was collected at a photon energy of 1820 eV and reconstructed using an iterative algorithm. A comparison with images recorded using transmission electron microscopy demonstrates that, while the resolution of these images is limited by the available flux and mechanical stability, we observed structures internal to the pollen grain-the intine/exine separations and pore dimensions-finer than 60 nm. The potential of this technique for further biological imaging applications is discussed.


Subject(s)
Algorithms , Convallaria/ultrastructure , Imaging, Three-Dimensional/methods , Microscopy, Electron, Transmission/methods , Pollen/ultrastructure , X-Ray Diffraction/methods , Holography
11.
Opt Express ; 20(21): 23361-6, 2012 Oct 08.
Article in English | MEDLINE | ID: mdl-23188299

ABSTRACT

We describe a direct quantitative phase reconstruction approach using an X-ray laboratory-based source. Using a single phase-contrast image from each tomographic projection we show that it is possible to modify the filter term in a filtered back projection reconstruction to take account of the broad spectrum from a laboratory source. The accessibility of conventional X-ray laboratory sources makes this method very useful for quantitative phase imaging of homogeneous and weakly absorbing objects.


Subject(s)
Image Enhancement/instrumentation , Refractometry/instrumentation , Tomography, X-Ray/instrumentation , Equipment Design , Equipment Failure Analysis
12.
Ultramicroscopy ; 111(8): 1184-8, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21762656

ABSTRACT

This paper demonstrates the application of the high sensitivity, low radiation dose imaging method recently presented as phase diverse coherent diffraction imaging, to the study of biological and other weakly scattering samples. The method is applied, using X-ray illumination, to quantitative imaging of the granular precursors of underwater adhesive produced by the marine sandcastle worm, Phragmatopoma californica. We are able to observe the internal structure of the adhesive precursors in a number of states.


Subject(s)
Adhesives/chemistry , Polychaeta/chemistry , Algorithms , Animals , Image Processing, Computer-Assisted , Microscopy/methods , Molecular Structure , Proteins/chemistry , X-Ray Diffraction/methods , X-Ray Diffraction/statistics & numerical data
13.
Opt Express ; 19(9): 8127-34, 2011 Apr 25.
Article in English | MEDLINE | ID: mdl-21643063

ABSTRACT

We introduce theoretically and demonstrate experimentally a contrast transfer function based phase retrieval algorithm that reconstructs the projected thickness of an homogeneous sample using a polychromatic x-ray source. We show excellent quantitative recovery of test samples in 2D using a synchrotron source with significant harmonic contamination, and in 3D using a laboratory source.


Subject(s)
Materials Testing/methods , Models, Theoretical , X-Rays , Computer Simulation
14.
Opt Lett ; 36(11): 1954-6, 2011 Jun 01.
Article in English | MEDLINE | ID: mdl-21633413

ABSTRACT

As the resolution in coherent diffractive imaging improves, interexposure and intraexposure sample dynamics, such as motion, degrade the quality of the reconstructed image. Selecting data sets that include only exposures where tolerably little motion has occurred is an inefficient use of time and flux, especially when detector readout time is significant. We provide an experimental demonstration of an approach in which all images of a data set exhibiting sample motion are combined to improve the quality of a reconstruction. This approach is applicable to more general sample dynamics (including sample damage) that occur during measurement.

15.
Phys Rev Lett ; 106(1): 013903, 2011 Jan 07.
Article in English | MEDLINE | ID: mdl-21231742

ABSTRACT

This Letter demonstrates that coherent diffractive imaging (CDI), in combination with phase-diversity methods, provides reliable and artefact free high-resolution images. Here, using x rays, experimental results show a threefold improvement in the available image contrast. Furthermore, in conditions requiring low imaging dose, it is demonstrated that phase-diverse CDI provides a factor of 2 improvement in comparison to previous CDI techniques.

16.
Opt Express ; 19(27): 25969-80, 2011 Dec 19.
Article in English | MEDLINE | ID: mdl-22274185

ABSTRACT

We report experimental demonstrations of a quantitative technique for elemental mapping. The technique operates in full-field imaging mode and uses three intensity measurements at energies across an absorption edge of an element of interest to obtain its elemental distribution. The experimental results show that the technique can overcome some limitations in the conventional Absorption Edge Contrast Imaging. The technique allows for an accurate determination of the elemental distribution in a compound sample even at a low level of percentage composition. It is also robust to the choice of energy intervals.


Subject(s)
Algorithms , Image Interpretation, Computer-Assisted/methods , Photometry/methods , Absorption
17.
Opt Express ; 17(16): 14156-65, 2009 Aug 03.
Article in English | MEDLINE | ID: mdl-19654826

ABSTRACT

The concept of an x-ray telescope based on the optics of the eye of certain types of crustacea has been in currency for nearly thirty years. However, it is only in the last decade that the technology to make the telescope and the opportunity to mount it on a suitable space platform have combined to allow the idea to become a reality. Accordingly, we have undertaken a detailed simulation study, updating previous simplified models, to properly characterise the performance of the instrument in orbit. The study reveals details of how the particular characteristics of the lobster-eye optics affect the sensitivity of the instrument and allow us to implement new ideas in data extraction methods.


Subject(s)
Astronomy/instrumentation , Biomimetic Materials , Crustacea/physiology , Lenses , Ocular Physiological Phenomena , Vision, Ocular/physiology , Animals , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Light , Models, Theoretical , Scattering, Radiation
18.
Opt Express ; 17(14): 11905-15, 2009 Jul 06.
Article in English | MEDLINE | ID: mdl-19582105

ABSTRACT

We present the first experimental demonstration of the astigmatic phase retrieval technique, in which the diffracted wavefield is distorted by cylindrical curvature in two orthogonal directions. A charge-one vortex, a charge-two vortex, and a simple test image are all correctly reconstructed.


Subject(s)
Optics and Photonics , Algorithms , Computer Simulation , Equipment Design , Image Interpretation, Computer-Assisted/methods , Information Storage and Retrieval , Lasers , Microscopy/methods , Optical Devices
19.
Cytometry A ; 73(10): 949-57, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18671251

ABSTRACT

Methods for imaging cellular architecture and ultimately macromolecular complexes and individual proteins, within a cellular environment, are an important goal for cell and molecular biology. Coherent diffractive imaging (CDI) is a method of lensless imaging that can be applied to any individual finite object. A diffraction pattern from a single biological structure is recorded and an iterative Fourier transform between real space and reciprocal space is used to reconstruct information about the architecture of the sample to high resolution. As a test system for cellular imaging, we have applied CDI to an important human pathogen, the malaria parasite, Plasmodium falciparum. We have employed a novel CDI approach, known as Fresnel CDI, which uses illumination with a curved incident wavefront, to image red blood cells infected with malaria parasites. We have examined the intrinsic X-ray absorption contrast of these cells and compared them with cells contrasted with heavy metal stains or immunogold labeling. We compare CDI images with data obtained from the same cells using scanning electron microscopy, light microscopy, and scanning X-ray fluorescence microscopy. We show that CDI can offer new information both within and at the surface of complex biological specimens at a spatial resolution of better than 40 nm. and we demonstrate an imaging modality that conveniently combines scanning X-ray fluorescence microscopy with CDI. The data provide independent confirmation of the validity of the coherent diffractive image and demonstrate that CDI offers the potential to become an important and reliable new high-resolution imaging modality for cell biology. CDI can detect features at high resolution within unsectioned cells.


Subject(s)
Erythrocytes/diagnostic imaging , Erythrocytes/parasitology , Plasmodium falciparum/isolation & purification , X-Ray Diffraction/methods , Animals , Erythrocytes/ultrastructure , Green Fluorescent Proteins/analysis , Green Fluorescent Proteins/genetics , Microscopy, Electron, Scanning Transmission , Microscopy, Fluorescence , Radiography , Transfection
20.
Ultramicroscopy ; 108(9): 937-45, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18502583

ABSTRACT

Optical coherence theory is used to describe image formation in a telecentric optical system. By assuming a weakly interacting object and by considering points that are not too far from the optical axis, an optical transfer function description is obtained for imaging both the phase and the amplitude components of the object. A dimensionless coordinate system is identified to allow the transfer functions to be expressed independently of the details of the imaging system. Phase-contrast imaging is found to have an essentially coherent behaviour when the coherence length is a factor of 15 larger than the system resolution, and that the coherent region of the illumination therefore does not need to encompass the object.