Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Radiol ; 74(11): 896.e17-896.e22, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31466797

ABSTRACT

AIM: To investigate the three-dimensional anatomy and shape of the proximal femur, comparing patients with secondary osteoarthritis (OA) due to mild developmental dysplasia of the hip (DDH) and primary hip OA. MATERIALS AND METHODS: This retrospective radiographic computed tomography (CT)-based study investigated proximal femoral anatomy in a consecutive series of 84 patients with secondary hip OA due to mild DDH (Crowe type I&II/Hartofilakidis A) compared to 84 patients with primary hip OA, matched for gender, age at surgery, and body mass index. RESULTS: Men with DDH showed higher neck shaft angles (127±5° vs. 123±4°; p<0.001), whereas women with DDH had a larger femoral head diameter (46±4 vs. 44±3 mm; p=0.002), smaller femoral offset (36±5 vs. 40±4 mm; p<0.001), decreased leg torsion (25±13° vs. 31±16°; p=0.037), and a higher neck shaft angle (128±7° vs. 123±4°; p<0.001) compared to primary OA patients. Similar patterns of the three-dimensional endosteal canal shape of the proximal femur, but a high inter-individual variability for femoral canal torsion at the meta-diaphyseal level were found for DDH and primary OA patients. CONCLUSION: Standard cementless stem designs are suitable to treat patients with secondary hip OA due to mild DDH; however, high patient variability and subtle anatomical differences in the proximal femur should be respected.


Subject(s)
Femur/pathology , Hip Dislocation, Congenital/pathology , Osteoarthritis, Hip/pathology , Arthroplasty, Replacement, Hip , Female , Hip Dislocation, Congenital/surgery , Humans , Male , Middle Aged , Observer Variation , Osteoarthritis, Hip/surgery , Retrospective Studies , Sex Characteristics , Tomography, X-Ray Computed
2.
Knee ; 22(6): 646-52, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26514940

ABSTRACT

BACKGROUND: Quantification of the in vivo position of the medial condyle throughout flexion is important for knee replacement design, and understanding knee pathology. The influence of consciousness, muscle action, and activity type on condyle translation was examined in patients who had undergone medial unicompartmental knee replacement (UKR) using lateral video fluoroscopy. METHODS: The position of the centre of the femoral component relative to the tibial component was measured for nine patients under different conditions. The following activities were assessed; passive flexion and extension when anaesthetised, passive flexion and extension when conscious, and active flexion, extension and step-up. RESULTS: The position of the centre of the femoral component relative to the tibial component was highly patient dependent. The greatest average translation range (14.9 mm) was observed in anaesthetised patients, and the condyle was significantly more anterior near to extension. Furthermore, when conscious but being moved passively, the femoral condyle translated a greater range (8.9 mm) than when moving actively (5.2mm). When ascending stairs, the femoral condyle was more posterior at 20-30° of flexion than during flexion/extension. CONCLUSIONS: The similarity between these results and published data suggest that knee kinematics following mobile-bearing UKR is relatively normal. The results show that in the normal knee and after UKR, knee kinematics is variable and is influenced by the patient, consciousness, muscle action, and activity type. CLINICAL RELEVANCE: It is therefore essential that all these factors are considered during knee replacement design, if the aim is to achieve more normal knee kinematics.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Consciousness/physiology , Fluoroscopy/methods , Knee Joint/physiopathology , Knee Prosthesis , Muscle, Skeletal/physiopathology , Osteoarthritis, Knee/surgery , Range of Motion, Articular/physiology , Video Recording , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Muscle, Skeletal/diagnostic imaging , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/physiopathology , Reproducibility of Results
3.
J R Soc Interface ; 11(96): 20140303, 2014 Jul 06.
Article in English | MEDLINE | ID: mdl-24759544

ABSTRACT

The assessment of radiolucency around an implant is qualitative, poorly defined and has low agreement between clinicians. Accurate and repeatable assessment of radiolucency is essential to prevent misdiagnosis, minimize cases of unnecessary revision, and to correctly monitor and treat patients at risk of loosening and implant failure. The purpose of this study was to examine whether a semi-automated imaging algorithm could improve repeatability and enable quantitative assessment of radiolucency. Six surgeons assessed 38 radiographs of knees after unicompartmental knee arthroplasty for radiolucency, and results were compared with assessments made by the semi-automated program. Large variation was found between the surgeon results, with total agreement in only 9.4% of zones and a kappa value of 0.602; whereas the automated program had total agreement in 81.6% of zones and a kappa value of 0.802. The software had a 'fair to excellent' prediction of the presence or the absence of radiolucency, where the area under the curve of the receiver operating characteristic curves was 0.82 on average. The software predicted radiolucency equally well for cemented and cementless implants (p = 0.996). The identification of radiolucency using an automated method is feasible and these results indicate that it could aid the definition and quantification of radiolucency.


Subject(s)
Image Interpretation, Computer-Assisted , Knee/diagnostic imaging , Prostheses and Implants , Software , Algorithms , Arthroplasty , Humans , Radiography , Technology, Radiologic/methods
4.
Eur J Radiol ; 82(8): 1278-85, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23639771

ABSTRACT

BACKGROUND: In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the accuracy and reliability of predicting three-dimensional (3-D) FO from standardised AP pelvis radiographs. METHODS: In a retrospective cohort study, pre-operative AP pelvis radiographs, AP hip radiographs and CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 19-57)kg/m(2)) with primary end-stage hip OA were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding radiographs and CT scans. Measurement reliability was evaluated using intra-class-correlation-coefficients. To predict 3-D FO from AP pelvis measurements and to assess the accuracy compared to CT, the entire cohort was randomly split into subgroups A and B. Gender specific regression equations were derived from group A (245 patients) and the accuracy of prediction was evaluated in group B (100 patients) using Bland-Altman plots. RESULTS: In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs, 44.1mm (95%CI: 43.4-44.9mm) on AP hip radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). CONCLUSIONS: The present study suggests that FO can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating on AP-pelvis radiographs and may improve offset and limb length restoration in THA without the routine performance of additional radiographs or CT.


Subject(s)
Femur/diagnostic imaging , Imaging, Three-Dimensional/statistics & numerical data , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/epidemiology , Patient Positioning/methods , Pelvis/diagnostic imaging , Tomography, X-Ray Computed/statistics & numerical data , Adult , Aged , Cohort Studies , Female , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Prevalence , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , United Kingdom/epidemiology
5.
Eur J Radiol ; 81(10): 2585-91, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22236703

ABSTRACT

Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p>0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p=0.0001). Less time (15s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.


Subject(s)
Algorithms , Artificial Intelligence , Models, Anatomic , Models, Statistical , Radiographic Image Enhancement/methods , Tibia/diagnostic imaging , Computer Simulation , Data Interpretation, Statistical , Female , Humans , Male , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Tibia/surgery
SELECTION OF CITATIONS