Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Biosensors (Basel) ; 11(11)2021 Oct 28.
Article in English | MEDLINE | ID: mdl-34821641

ABSTRACT

Periodontitis and dental caries are two major bacterially induced, non-communicable diseases that cause the deterioration of oral health, with implications in patients' general health. Early, precise diagnosis and personalized monitoring are essential for the efficient prevention and management of these diseases. Here, we present a disk-shaped microfluidic platform (OralDisk) compatible with chair-side use that enables analysis of non-invasively collected whole saliva samples and molecular-based detection of ten bacteria: seven periodontitis-associated (Aggregatibacter actinomycetemcomitans, Campylobacter rectus, Fusobacterium nucleatum, Prevotella intermedia, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola) and three caries-associated (oral Lactobacilli, Streptococcus mutans, Streptococcus sobrinus). Each OralDisk test required 400 µL of homogenized whole saliva. The automated workflow included bacterial DNA extraction, purification and hydrolysis probe real-time PCR detection of the target pathogens. All reagents were pre-stored within the disk and sample-to-answer processing took < 3 h using a compact, customized processing device. A technical feasibility study (25 OralDisks) was conducted using samples from healthy, periodontitis and caries patients. The comparison of the OralDisk with a lab-based reference method revealed a ~90% agreement amongst targets detected as positive and negative. This shows the OralDisk's potential and suitability for inclusion in larger prospective implementation studies in dental care settings.


Subject(s)
Dental Caries , Microfluidic Analytical Techniques , Oral Health , Periodontitis , Saliva/microbiology , Dental Caries/diagnosis , Humans , Periodontitis/diagnosis
2.
Animals (Basel) ; 11(5)2021 May 10.
Article in English | MEDLINE | ID: mdl-34068648

ABSTRACT

Currently about 30% to 50% of all dairy cows are affected by a metabolic or infectious disease during the transition period. A key factor for preventive actions is the ability to precisely predict metabolic diseases at an early stage. We report the longitudinal metabolic profile of non-esterified fatty acids, beta-hydroxybutyrate (BHB), total bilirubin, and aspartate aminotransferase in hyperketonemic dairy cows. Aiming for a novel measurement regime to improve metabolic health in dairy cows, we evaluated prognostic classifiers for hyperketonemia. In the observational longitudinal study, 99 healthy adult primiparous and multiparous Simmental dairy cows were included. Every cow was monitored weekly for 14 consecutive weeks, beginning two weeks prior to the expected day of parturition until peak lactation. Cows with serum concentrations of BHB > 0.8 mmol/L were considered hyperketonemic. Biomarker profiles were fitted by the maximum likelihood method using a mixed effects natural cubic spline model. In the hyperketonemic group, the BHB profile remained significantly higher than that of the control group until the end of the study period. As a prognostic classifier, the cut-off level of 0.54 mmol/L BHB measured on the 10th day post partum had the highest area under the curve. These results provide new longitudinal insights into the metabolic biomarker progression of dairy cows and enable an early onset diagnosis of hyperketonemia.

3.
J Pers Med ; 11(3)2021 Mar 23.
Article in English | MEDLINE | ID: mdl-33806927

ABSTRACT

This study investigated the potential of salivary bacterial and protein markers for evaluating the disease status in healthy individuals or patients with gingivitis or caries. Saliva samples from caries- and gingivitis-free individuals (n = 18), patients with gingivitis (n = 17), or patients with deep caries lesions (n = 38) were collected and analyzed for 44 candidate biomarkers (cytokines, chemokines, growth factors, matrix metalloproteinases, a metallopeptidase inhibitor, proteolytic enzymes, and selected oral bacteria). The resulting data were subjected to principal component analysis and used as a training set for random forest (RF) modeling. This computational analysis revealed four biomarkers (IL-4, IL-13, IL-2-RA, and eotaxin/CCL11) to be of high importance for the correct depiction of caries in 37 of 38 patients. The RF model was then used to classify 10 subjects (five caries-/gingivitis-free and five with caries), who were followed over a period of six months. The results were compared to the clinical assessments of dental specialists, revealing a high correlation between the RF prediction and the clinical classification. Due to the superior sensitivity of the RF model, there was a divergence in the prediction of two caries and four caries-/gingivitis-free subjects. These findings suggest IL-4, IL-13, IL-2-RA, and eotaxin/CCL11 as potential salivary biomarkers for identifying noninvasive caries. Furthermore, we suggest a potential association between JAK/STAT signaling and dental caries onset and progression.

4.
Animals (Basel) ; 11(4)2021 Apr 07.
Article in English | MEDLINE | ID: mdl-33917264

ABSTRACT

Currently, subclinical metabolic imbalances at the individual cow and herd level are detected by measuring biomarkers in single blood samples. However, diurnal variations have not been fully described yet but need to be considered when sampling for a robust ad consistent analysis. The study describes the influence of lactation phases on circadian rhythms and diurnal variations for non-esterified fatty acids (NEFA), beta-hydroxybutyrate (BHB), total bilirubin (tBIL) and aspartate aminotransferase (AST) in dairy cows. In an observational pilot study, we used 16 clinically healthy Simmental dairy cows subdivided in four different lactation stages (dry-off, fresh, high and late lactating). Every cow was monitored for 24 h, with blood sampling and assessment of clinical parameters every 2 h. Time and lactation stage influence the concentration of the biomarkers NEFA, BHB and tBIL in serum. Further, circadian rhythmicity was found in high lactating cows for NEFA peaking at 5:39 am and BHB peaking at 4:20 pm. We suggest blood sampling for single-point measurements within three hours after the first feeding until two hours after the last feeding of the day. The results provide a new insight into the physiology of circadian rhythms in dairy cows and enable improved metabolic monitoring.

5.
Pharmaceutics ; 13(2)2021 Feb 12.
Article in English | MEDLINE | ID: mdl-33673378

ABSTRACT

C-reactive protein (CRP) is a commonly used serum biomarker for detecting sepsis in neonates. After the onset of sepsis, serial measurements are necessary to monitor disease progression; therefore, a non-invasive detection method is beneficial for neonatal well-being. While some studies have shown a correlation between serum and salivary CRP levels in septic neonates, the causal link behind this correlation remains unclear. To investigate this relationship, CRP was examined in serum and saliva samples from 18 septic neonates and compared with saliva samples from 22 healthy neonates. While the measured blood and saliva concentrations of the septic neonates varied individually, a correlation of CRP levels between serum and saliva samples was observed over time. To clarify the presence of active transport of CRP across the blood-salivary barrier (BSB), transport studies were performed with CRP using in vitro models of oral mucosa and submandibular salivary gland epithelium. The results showed enhanced transport toward saliva in both models, supporting the clinical relevance for salivary CRP as a biomarker. Furthermore, CRP regulated the expression of the receptor for advanced glycation end products (RAGE) and the addition of soluble RAGE during the transport studies indicated a RAGE-dependent transport process for CRP from blood to saliva.

6.
Analyst ; 145(21): 7040-7047, 2020 Oct 26.
Article in English | MEDLINE | ID: mdl-33103683

ABSTRACT

We present the RespiDisk enabling the fully automated and multiplex point-of-care (POC) detection of (currently) up to 19 respiratory tract infection (RTI) pathogens from a single sample based on reverse transcriptase polymerase chain reaction (RT-PCR). RespiDisk comprises a RTI-specific implementation of the centrifugal microfluidic LabDisk platform and combines new and existing advanced unit operations for liquid control, thereby automating all assay steps only by a spinning frequency and temperature protocol in combination with the use of a permanent magnet for in situ bead handing. The capabilities of the system were demonstrated with 36 tested quality samples mimicking clinical conditions (clinical and/or cultured material suspended in transport medium or synthetic bronchoalveolar lavage (BAL)) from past external quality assessment (EQA) panels covering 13 of the 19 integrated RTI detection assays. In total, 36 samples × 19 assays/sample resulting in 684 assays were performed with the RespiDisk, and its analytical performance was in full agreement with the routine clinical workflow serving as reference. A strong feature of the platform is its universality since its components allow the simultaneous detection of a broad panel of bacteria and viruses in a single run, thereby enabling the differentiation between antibiotic-treatable diseases. Furthermore, the full integration of all necessary biochemical components enables a reduction of the hands-on time from manual to automated sample-to-answer analysis to about 5 min. The study was performed on an air-heated LabDisk Player instrument with a time-to-result of 200 min.


Subject(s)
Respiratory Tract Infections , Viruses , Bacteria , Humans , Microfluidics , Point-of-Care Systems , Respiratory Tract Infections/diagnosis
7.
J Clin Med ; 9(9)2020 Sep 11.
Article in English | MEDLINE | ID: mdl-32933084

ABSTRACT

Oral health is maintained by a healthy microbiome, which can be monitored by state-of-the art diagnostics. Therefore, this study evaluated the presence and quantity of ten oral disease-associated taxa (P. gingivalis, T. forsythia, T. denticola, F. nucleatum, C. rectus, P. intermedia, A. actinomycetemcomitans, S. mutans, S. sobrinus, oral associated Lactobacilli) in saliva and their clinical status association in 214 individuals. Upon clinical examination, study subjects were grouped into healthy, caries and periodontitis and their saliva was collected. A highly specific point-of-care compatible dual color qPCR assay was developed and used to study the above-mentioned bacteria of interest in the collected saliva. Assay performance was compared to a commercially available microbial reference test. Eight out of ten taxa that were investigated during this study were strong discriminators between the periodontitis and healthy groups: C. rectus, T. forsythia, P. gingivalis, S. mutans, F. nucleatum, T. denticola, P. intermedia and oral Lactobacilli (p < 0.05). Significant differentiation between the periodontitis and caries group microbiome was only shown for S. mutans (p < 0.05). A clear distinction between oral health and disease was enabled by the analysis of quantitative qPCR data of target taxa levels in saliva.

8.
Biomedicines ; 8(9)2020 Aug 23.
Article in English | MEDLINE | ID: mdl-32842479

ABSTRACT

The blood-saliva barrier (BSB) consists of the sum of the epithelial cell layers of the oral mucosa and salivary glands. In vitro models of the BSB are inevitable to investigate and understand the transport of salivary biomarkers from blood to saliva. Up to now, standardized, cell line-based models of the epithelium of the submandibular salivary gland are still missing for this purpose. Therefore, we established epithelial barrier models of the submandibular gland derived from human cell line HTB-41 (A-253). Single clone isolation resulted in five different clones (B2, B4, B9, D3, and F11). Clones were compared to the parental cell line HTB-41 using measurements of the transepithelial electrical resistance (TEER), paracellular marker permeability assays and analysis of marker expression for acinar, ductal, and myoepithelial cells. Two clones (B9, D3) were characterized to be of acinar origin, one clone (F11) to be of myoepithelial origin and one isolation (B4) derived from two cells, to be presumably a mixture of acinar and ductal origin. Clone B2, presumably of ductal origin, showed a significantly higher paracellular barrier compared to other clones and parental HTB-41. The distinct molecular identity of clone B2 was confirmed by immunofluorescent staining, qPCR, and flow cytometry. Experiments with ferritin, a biomarker for iron storage, demonstrated the applicability of the selected model based on clone B2 for transport studies. In conclusion, five different clones originating from the submandibular gland cell line HTB-41 were successfully characterized and established as epithelial barrier models. Studies with the model based on the tightest clone B2 confirmed its suitability for transport studies in biomarker research.

9.
Lab Chip ; 19(23): 3997-4006, 2019 12 07.
Article in English | MEDLINE | ID: mdl-31667478

ABSTRACT

Systems designed toward cell manipulation by electric fields are inherently challenged by energy dissipation along the electrode-electrolyte interface. A promising remedy is the introduction of high-k electrode passivation, enabling efficient capacitive coupling of electric fields into biological samples. We present the implementation of this strategy in a reusable pipette tip design featuring a 10 µl chamber volume for life science applications. Prototype validation and comparison to conductive gold-coated electrodes reveal a consistent and controllable biological effect that significantly increases the reproducibility of lysis events. The system provides precise descriptions of HEK-293 lysis dependency to variables such as field strength, frequency, and conductivity. Over 80% of cells were reversibly electroporated with minimal electrical lysis over a broad range of field settings. Successful transfection requires exponential decay pulses and showcases how modulating capacitive coupling can advance our understanding of fundamental mechanics in the field of electroporation.


Subject(s)
Microfluidic Analytical Techniques/instrumentation , Cells, Cultured , Electricity , Electrodes , Equipment Design , Gold/chemistry , HEK293 Cells , Humans , Optical Imaging
10.
Anal Chem ; 89(9): 4817-4823, 2017 05 02.
Article in English | MEDLINE | ID: mdl-28382820

ABSTRACT

This Article presents an automated, compact, and self-contained system for sensitive quantitative detection of blood biomarkers. A disposable microfluidic chip, prefilled with biomarker-specific reagents and magnetic beads, can be processed fully automatically by a readout platform, enabling an immunoassay-based analysis with a processing time from sample incubation to signal analysis of 20 min. Novel concepts for on-chip vortexing of the magnetic beads and on-chip reagent storage and actuation were developed. A lens-free photodiode readout system represents a cost-efficient approach for detecting the chemiluminescent signal. IL-8 spiked serum samples were measured with a high reproducibility and a limit of detection of 2.05 pg·mL-1. The system was validated with undiluted serum samples collected from trauma patients at the intensive care unit. The developed platform demonstrated good correlation with the clinical reference method, and the clinical trajectory course of IL-8 could be sufficiently followed. With an automated assay approach and an easily adaptable protocol, this portable platform has the potential to be utilized as a universal instrument for analyzing proteins in small sample volumes (<25 µL) in point-of-care settings.


Subject(s)
Biomarkers/blood , Immunoassay/methods , Interleukin-8/blood , Microfluidic Analytical Techniques/methods , Monitoring, Immunologic/methods , Antibodies/immunology , Humans , Interleukin-8/immunology , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Point-of-Care Systems , Reproducibility of Results
11.
ACS Appl Mater Interfaces ; 8(33): 21228-35, 2016 Aug 24.
Article in English | MEDLINE | ID: mdl-27466697

ABSTRACT

A better understanding of the electrodynamic behavior of cells interacting with electric fields would allow for novel scientific insights and would lead to the next generation of cell manipulation, diagnostics, and treatment. Here, we introduce a promising electrode design by using metal oxide high-k dielectric passivation. The thermally generated dielectric passivation layer enables efficient electric field coupling to the fluid sample comprising cells while simultaneously decoupling the electrode ohmically from the electrolyte, allowing for better control and adjustability of electric field effects due to reduced electrochemical reactions at the electrode surface. This approach demonstrates cell-size specific lysis with electric fields in a microfluidic flow-through design resulting in 99.8% blood cell lysis at 6 s exposure without affecting the viability of Gram-positive and Gram-negative bacterial spike-ins. The advantages of this new approach can support next-generation investigations of electrodynamics in biological systems and their exploitation for cell manipulation in multiple fields of medicine, life science, and industry.


Subject(s)
Electricity , Cell Death , Electrodes , Gram-Negative Bacteria , Microfluidics
12.
Stud Health Technol Inform ; 224: 61-6, 2016.
Article in English | MEDLINE | ID: mdl-27225554

ABSTRACT

Global healthcare systems are struggling with the enormous burden associated with infectious diseases, as well as the incessant rise of antimicrobial resistance. In order to adequately address these issues, there is an urgent need for rapid and accurate infectious disease diagnostics. The H2020 project DIAGORAS aims at diagnosing oral and respiratory tract infections using a fully integrated, automated and user-friendly platform for physicians' offices, schools, elderly care units, community settings, etc. Oral diseases (periodontitis, dental caries) will be detected via multiplexed, quantitative analysis of salivary markers (bacterial DNA and host response proteins) for early prevention and personalised monitoring. Respiratory Tract Infections will be diagnosed by means of DNA/RNA differentiation so as to identify their bacterial or viral nature. Together with antibiotic resistance screening on the same platform, a more efficient treatment management is expected at the point-of-care. At the heart of DIAGORAS lies a centrifugal microfluidic platform (LabDisk and associated processing device) integrating all components and assays for a fully automated analysis. The project involves an interface with a clinical algorithm for the comprehensive presentation of results to end-users, thereby increasing the platform's clinical utility. DIAGORAS' performance will be validated at clinical settings and compared with gold standards.


Subject(s)
Dental Caries/diagnosis , Drug Resistance, Bacterial , Periodontitis/diagnosis , Respiratory Tract Infections/diagnosis , Automation, Laboratory , Centrifugation/methods , DNA, Bacterial/analysis , Humans , Microfluidic Analytical Techniques , Periodontitis/microbiology , Precision Medicine/methods , RNA, Viral/analysis , Respiratory Tract Infections/microbiology , Respiratory Tract Infections/virology , Saliva/immunology , Saliva/microbiology
13.
Biomed Microdevices ; 18(1): 16, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26842948

ABSTRACT

We present a compact diagnostic platform for a rapid and sensitive detection of plasma biomarkers. The platform consists of a disposable microfluidic polymer chip, a processing device including a lens-free and cost efficient sensor system and a setup for dispersion of magnetic particles. The biomarkers of interest are quantified by magnetic bead based immunoassays with chemiluminescent readout technology. With a novel system for dispersion and manipulation of the magnetic particles in combination with chemiluminescence detection, the sensitivity of the immunoassay is improved and enables a rapid assay in a microfluidic format. In the disposable chip, extra chambers for storage and dispensing of biomarker specific reagents are integrated, which reduce the need of external dosing devices and thereby the cost of the platform is decreased. Plasma biomarkers for monitoring of sepsis could be quantified at 10 pg/mL concentrations within a total time of 30 min by the present system. This contribution is a fundamental step towards the development of an automatic and compact Point-of-Care testing device for monitoring of patients at the intensive care unit.


Subject(s)
Interleukin-8/blood , Lab-On-A-Chip Devices , Magnetic Fields , Microfluidic Analytical Techniques , Nanoparticles/chemistry , Humans , Immunoassay/instrumentation , Immunoassay/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods
14.
Biomed Microdevices ; 13(3): 463-73, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21271358

ABSTRACT

In this article we present a long target droplet polymerase chain reaction (PCR) microsystem for the amplification of the 16S ribosomal RNA gene. It is used for detecting Gram-positive and Gram-negative pathogens at high-throughput and is optimised for downstream species identification. The miniaturised device consists of three heating plates for denaturation, annealing and extension arranged to form a triangular prism. Around this prism a fluoropolymeric tubing is coiled, which represents the reactor. The source DNA was thermally isolated from bacterial cells without any purification, which proved the robustness of the system. Long target sequences up to 1.3 kbp from Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa have successfully been amplified, which is crucial for the successive species classification with DNA microarrays at high accuracy. In addition to the kilobase amplicon, detection limits down to DNA concentrations equivalent to 10(2) bacterial cells per reaction were achieved, which qualifies the microfluidic device for clinical applications. PCR efficiency could be increased up to 2-fold and the total processing time was accelerated 3-fold in comparison to a conventional thermocycler. Besides this speed-up, the device operates in continuous mode with consecutive droplets, offering a maximal throughput of 80 samples per hour in a single reactor. Therefore we have overcome the trade-off between target length, sensitivity and throughput, existing in present literature. This qualifies the device for the application in species identification by PCR and microarray technology with high sample numbers. Moreover early diagnosis of infectious diseases can be implemented, allowing immediate species specific antibiotic treatment. Finally this can improve patient convalescence significantly.


Subject(s)
Bacteria/genetics , Bacteria/isolation & purification , Microfluidic Analytical Techniques/instrumentation , Polymerase Chain Reaction/instrumentation , Animals , Cattle , Humans , Limit of Detection , Quality Control , RNA, Bacterial/chemistry , RNA, Bacterial/genetics , RNA, Ribosomal, 16S/chemistry , RNA, Ribosomal, 16S/genetics , Time Factors
15.
Cell Oncol ; 31(5): 345-56, 2009.
Article in English | MEDLINE | ID: mdl-19759415

ABSTRACT

BACKGROUND: The group IIA secretory phospholipase A2 gene, Pla2g2a, confers resistance to intestinal tumorigenesis in the Apc(Min/+) mouse model. However, it is unclear how Pla2g2a exerts its tumor-suppressive effects and whether its mode of action depends on Apc-germline mutations. METHODS: We tested whether expression of a Pla2g2a transgene provides protection against carcinogen-induced colon tumors, and examined whether the normal colon microenvironment is modulated by Pla2g2a expression. RESULTS: Pla2g2a strongly inhibited colon tumorigenesis in mice following treatment with the DNA alkylating agent azoxymethane (AOM). Moreover, AOM-induced duodenal tumors were also attenuated by Pla2g2a expression. These tumors demonstrated upregulation of beta-catenin, indicative of involvement of the Wnt signaling pathway. Comparison of genome-wide microarray expression profiles of healthy (non-pathologic) colon tissues from Pla2g2a-transgenic to non-transgenic mice revealed 382 genes that were differentially expressed, comprising clusters of genes involved in inflammation and microbial defense, cell signaling and cell cycle, transactivation, apoptosis and mitochondrial function, DNA repair, and lipid and energy metabolism. Pathway analysis using Gene Set Enrichment Analysis (GSEA) indicated that Pla2g2a suppresses the expression of interferon-induced genes. CONCLUSION: Our results demonstrate that Pla2g2a attenuates colon tumorigenesis independent of Apc-germline mutations, and reveal Pla2g2a target genes and pathways in non-pathologic colon microenvironment that influence conditions for colorectal cancer development.


Subject(s)
Cell Transformation, Neoplastic/metabolism , Cell Transformation, Neoplastic/pathology , Colonic Neoplasms/metabolism , Colonic Neoplasms/pathology , Gene Expression Regulation, Neoplastic , Group II Phospholipases A2/metabolism , Animals , Azoxymethane/toxicity , Carcinogens/toxicity , Cell Transformation, Neoplastic/chemically induced , Cell Transformation, Neoplastic/genetics , Colonic Neoplasms/chemically induced , Colonic Neoplasms/genetics , Disease Models, Animal , Female , Gene Expression Regulation, Neoplastic/drug effects , Group II Phospholipases A2/genetics , Male , Mice , Mice, Inbred C57BL , Mice, Transgenic
SELECTION OF CITATIONS
SEARCH DETAIL
...