Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Strength Cond Res ; 33 Suppl 1: S95-S102, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30234695

ABSTRACT

Morales-Artacho, AJ, García-Ramos, A, Pérez-Castilla, A, Padial, P, Gomez, AM, Peinado, AM, Pérez-Córdoba, JL, and Feriche, B. Muscle activation during power-oriented resistance training: continuous vs. cluster set configurations. J Strength Cond Res 33(7S): S95-S102, 2019-This study examined performance and electromyography (EMG) changes during a power training protocol comprising continuous or clustered set configurations. Eighteen active males completed 6 sets of 6 repetitions during the loaded (20% 1 repetition maximum) countermovement jump (CMJ) exercise, continuously (n = 9) or with a 30-second pause every 2 repetitions (cluster; n = 9). Power output, vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) EMG were recorded during all CMJs. Relative changes from the first repetition were assessed on the EMG root mean square (RMS), median frequency (Fmed), and a low- to high-frequency ratio index of fatigue (FInsmk). Greater power output decrements were observed during the continuous set configuration (p = 0.001, (Equation is included in full-text article.)< 0.01). Greater RMS increments in VL (6.8 ± 11.3 vs. -1.7 ± 5.8%) and RF (9.3 ± 14.2 vs. 1.9 ± 6.9%), but not VM (2.0 ± 4.7 vs. 2.6 ± 7.3%), were also observed in the continuous compared with the cluster sets (p = 0.033, (Equation is included in full-text article.)= 0.06). Progressive decrements in Fmed and increments in FInsmk were observed across repetitions in both set configurations. In conclusion, although clustering sets between repetitions clearly maintained power output, mixed responses were observed on the examined EMG parameters.


Subject(s)
Muscle Fatigue , Quadriceps Muscle/physiology , Resistance Training/methods , Weight Lifting/physiology , Adult , Electromyography , Humans , Male , Muscle Strength , Young Adult
2.
J Bioinform Comput Biol ; 13(5): 1550024, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26434573

ABSTRACT

Most of the algorithms used for information extraction and for processing the amino acid chains that make up proteins treat them as symbolic chains. Fewer algorithms exploit signal processing techniques that require a numerical representation of amino acid chains. However, these algorithms are very powerful for extracting regularities that cannot be detected when working with a symbolic chain, which may be important for understanding the biological meaning of a sequence or in classification tasks. In this study, a new mathematical representation of amino acid chains is proposed, which is derived using a similarity measure based on the PAM250 amino acid substitution matrix and that generates 20 signals for each protein sequence. Using this representation 20 consensus spectra for a protein family are determined and the relevance of the frequency peaks is established, obtaining a group of significant frequency peaks that manifest common periodicities of the amino acid sequences that belong to a protein family. We also show that the proposed representation in 20 signals can be integrated into Chou's pseudo amino acid composition (PseAAC) and constitute a useful alternative to amino acid physicochemical properties in Chou's PseAAC.


Subject(s)
Algorithms , Proteins/chemistry , Amino Acid Sequence , Amino Acid Substitution , Amino Acids/chemistry , Computational Biology/methods , Consensus Sequence , Databases, Protein/statistics & numerical data , Markov Chains
3.
Opt Express ; 19(17): 15937-46, 2011 Aug 15.
Article in English | MEDLINE | ID: mdl-21934957

ABSTRACT

Interferometric gravitational wave detectors with an unequal and time-varying arm length configuration like the Laser Interferometer Space Antenna rely on time-delay interferometry (TDI) for laser frequency noise subtraction. However, the TDI algorithm requires a laser ranging scheme with meter accuracy over a five million kilometer arm length. At the end of each arm only about 100 pW of light power will be detected for gravitational wave measurements and only 1% of this power can be used for laser ranging in order to avoid degradation in the phase stability of the science measurements. Here, we present the first experimental demonstration of such a ranging scheme at 1 pW power levels using a Direct Sequence Spread Spectrum (DS/SS) modulation. This type of modulation also enables optical communication by encoding data with ranging signals and provides significant noise reduction against spurious interfering signals for bidirectional ranging. Experimental results show ranging measurements of 42 cm at 3 Hz and the viability of highly reliable data transfer at several kilobits per second.

SELECTION OF CITATIONS
SEARCH DETAIL
...