Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Rheumatol ; 36(9): 1892-902, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19648304

ABSTRACT

OBJECTIVE: This randomized controlled study addressed whether sonographic needle guidance affected clinical outcomes of intraarticular (IA) joint injections. METHODS: In total, 148 painful joints were randomized to IA triamcinolone acetonide injection by conventional palpation-guided anatomic injection or sonographic image-guided injection enhanced with a one-handed control syringe (the reciprocating device). A one-needle, 2-syringe technique was used, where the first syringe was used to introduce the needle, aspirate any effusion, and anesthetize and dilate the IA space with lidocaine. After IA placement and synovial space dilation were confirmed, a syringe exchange was performed, and corticosteroid was injected with the second syringe through the indwelling IA needle. Baseline pain, procedural pain, pain at outcome (2 weeks), and changes in pain scores were measured with a 0-10 cm visual analog pain scale (VAS). RESULTS: Relative to conventional palpation-guided methods, sonographic guidance resulted in 43.0% reduction in procedural pain (p < 0.001), 58.5% reduction in absolute pain scores at the 2 week outcome (p < 0.001), 75% reduction in significant pain (VAS pain score > or = 5 cm; p < 0.001), 25.6% increase in the responder rate (reduction in VAS score > or = 50% from baseline; p < 0.01), and 62.0% reduction in the nonresponder rate (reduction in VAS score < 50% from baseline; p < 0.01). Sonography also increased detection of effusion by 200% and volume of aspirated fluid by 337%. CONCLUSION: Sonographic needle guidance significantly improves the performance and outcomes of outpatient IA injections in a clinically significant manner.


Subject(s)
Adrenal Cortex Hormones/administration & dosage , Arthritis, Rheumatoid/drug therapy , Injections, Intra-Articular/methods , Joints/diagnostic imaging , Osteoarthritis/drug therapy , Triamcinolone Acetonide/administration & dosage , Adrenal Cortex Hormones/therapeutic use , Adult , Aged , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Pain Measurement , Treatment Outcome , Triamcinolone Acetonide/therapeutic use , Ultrasonography
2.
J Clin Rheumatol ; 15(2): 56-60, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19265345

ABSTRACT

PURPOSE: We hypothesized that the size of syringe influenced needle control in physician-performed procedures. MATERIALS AND METHODS: Operators were tested for their ability to control a 1-, 3-, 5-, 10-, and 20-mL syringe and equivalent sizes of the new safety device, the reciprocating procedure device (RPD), using the quantitative needle-based displacement method. Three hundred twenty clinical syringe procedures were then randomized to either a 3- or 10-mL conventional syringe or to a 3- or 10-mL RPD. Patient pain was measured with the Visual Analog Pain Scale (VAPS). RESULTS: Increasing syringe size was associated with the undesirable characteristic of unintended forward penetration (loss of control of the needle in the forward direction) (r(2) = 0.97, slope = 2.14, 95% CI: 1.54-2.76, P < 0.002), and unintended retraction (loss of control of the needle in the reverse direction) (r(2) = 0.97, slope 2.15, 95% CI: 1.54-2.76, P < 0.002). In addition, 2-handed operation of a syringe resulted in greater control than 1-handed operation of a syringe (P < 0.001). When 1-handed operation was required, the RPD control syringe reduced unintended penetration by 52.3% (P >or= 0.001), unintended retraction by 56.8% (P >or= 0.001), and patient pain by 54.7% (P >or= 0.001) at each device size. CONCLUSIONS: For greater safety and control when operating the conventional syringe, smaller syringe sizes and 2 hands instead of 1 hand should be used whenever possible. If 1-handed operation of a syringe is necessary, a safety technology like the RPD control syringe should be used.


Subject(s)
Clinical Competence , Injections, Intra-Articular/instrumentation , Pain/etiology , Syringes/adverse effects , Equipment Design/adverse effects , Humans , Pain Measurement
4.
Arthritis Rheum ; 58(7): 1907-14, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18576358

ABSTRACT

OBJECTIVE: To identify and integrate new safety technologies into outpatient musculoskeletal procedures and measure the effect on outcome, including pain. METHODS: Using national resources for patient safety and literature review, the following safety technologies were identified: a safety needle to reduce inadvertent needlesticks to heath care workers, and the reciprocating procedure device (RPD) to improve patient safety and reduce pain. Five hundred sixty-six musculoskeletal procedures involving syringes and needles were randomized to either an RPD group or a conventional syringe group, and pain, quality, safety, and physician acceptance were measured. RESULTS: During 566 procedures, no accidental needlesticks occurred with safety needles. Use of the RPD resulted in a 35.4% reduction (95% confidence interval [95% CI] 24-46%) in patient-assessed pain (mean +/- SD scores on a visual analog pain scale [VAPS] 3.12 +/- 2.23 for the RPD and 4.83 +/- 3.22 for the conventional syringe; P < 0.001) and a 49.5% reduction (95% CI 34-64%) in patient-assessed significant pain (VAPS score > or =5) (P < 0.001). Physician acceptance of the RPD combined with a safety needle was excellent. CONCLUSION: As mandated by the Joint Commission and the Occupational Safety and Health Administration, safety technologies and the use of pain scales can be successfully integrated into rheumatologic and orthopedic procedures. The combination of a safety needle to reduce needlestick injuries to health care workers and the RPD to improve safety and outcome of patients is effective and well accepted by physicians.


Subject(s)
Injections, Intra-Articular/instrumentation , Needles , Needlestick Injuries/prevention & control , Pain/prevention & control , Safety , Syringes , Adult , Aged , Equipment Design , Female , Humans , Injections, Intra-Articular/adverse effects , Male , Middle Aged , Pain/etiology , Pain Measurement , Patient Satisfaction
5.
J Rheumatol ; 35(6): 1124-9, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18412301

ABSTRACT

OBJECTIVE: To investigate the relationship of needle control to tissue trauma and hemorrhage during syringe procedures. METHODS: Forty-seven subjects with a palpable knee effusion underwent needle and syringe aspiration. Subjects were randomized to the conventional syringe or a safety technology, the reciprocating procedure device (RPD). This trial was registered at clinicaltrials.gov. Pain was measured with the Visual Analog Pain Scale (VAPS). Cell count, crystal examination, culture, and aspirated fluid volume were determined. Red blood cell (RBC) counts were used to measure blood in aspirated fluid. RESULTS: Patient pain during the syringe procedure significantly predicted blood (RBC) in aspirated fluid (r = 0. 53, p = 0.001). When compared to the conventional syringe, the RPD safety device reduced blood in aspirated fluid by 66.7% (RBC, 10(3)/ml: RPD 8.9 +/- 11.4; syringe 26.7 +/- 90.2; p 0.01), reduced patient pain by 73.9% (VAPS: RPD 1.68 +/- 2.34; syringe 6.44 +/- 2.86; p < 0.01), and improved fluid aspirate yield by 132% (aspirate volume: RPD 20.9 +/- 19.7 ml; syringe 9.00 +/- 6.58 ml; p < 0.01). CONCLUSION: Inadequate control of needle and syringe during physician-performed syringe procedures is an important cause of trauma to patient tissues resulting in hemorrhage, increased patient pain, and decreased aspirate yield. The RPD -- a safety device that improves needle control and decreases needle trauma to tissues -- reduces hemorrhage and improves the safety, outcome, and aspirate yield of physician-performed syringe procedures.


Subject(s)
Knee , Suction/adverse effects , Suction/instrumentation , Adult , Equipment Design , Female , Humans , Knee Injuries/etiology , Male , Middle Aged , Pain , Pain Measurement , Synovial Fluid , Syringes/adverse effects
6.
Expert Rev Clin Immunol ; 4(3): 379-90, 2008 May.
Article in English | MEDLINE | ID: mdl-20476927

ABSTRACT

C-reactive protein (CRP), the prototypic acute-phase protein, increases rapidly in response to infection and inflammation. Although CRP was thought to be a passive, nonspecific marker of inflammation, recent studies indicate that CRP plays a key role in the innate immune system by recognizing pathogens and altered self determinants. Activation of complement and interaction with Fcgamma receptors by CRP provides a link between the innate and adaptive immune systems. Recent evidence suggests that CRP is a marker of atherosclerotic disease and may play a role in its induction. However, CRP has an anti-inflammatory role in autoimmune diseases, such as systemic lupus erythematosus. In this article, we review the biological mechanisms by which CRP exerts its effects on the immune system and discuss its role in infection, cardiovascular disease, malignancy and systemic lupus erythematosus.