Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
medRxiv ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39314938

ABSTRACT

Motivation: The clinical success of brain-machine interfaces depends on overcoming both biological and material challenges to ensure a long-term stable connection for neural recording and stimulation. Therefore, there is a need to quantify any damage that microelectrodes sustain when they are chronically implanted in the human cortex. Methods: Using scanning electron microscopy (SEM), we imaged 980 microelectrodes from Neuroport arrays chronically implanted in the cortex of three people with tetraplegia for 956-2246 days. We analyzed eleven multi-electrode arrays in total: eight arrays with platinum (Pt) electrode tips and three with sputtered iridium oxide tips (SIROF); one Pt array was left in sterile packaging, serving as a control. The arrays were implanted/explanted across three different clinical sites surgeries (Caltech/UCLA, Caltech/USC and APL/Johns Hopkins) in the anterior intraparietal area, Brodmann's area 5, motor cortex, and somatosensory cortex.Human experts rated the electron micrographs of electrodes with respect to five damage metrics: the loss of metal at the electrode tip, the amount of separation between the silicon shank and tip metal, tissue adherence or bio-material to the electrode, damage to the shank insulation and silicone shaft. These metrics were compared to functional outcomes (recording quality, noise, impedance and stimulation ability). Results: Despite higher levels of physical degradation, SIROF electrodes were twice as likely to record neural activity than Pt electrodes (measured by SNR), at the time of explant. Additionally, 1 kHz impedance (measured in vivo prior to explant) significantly correlated with all physical damage metrics, recording, and stimulation performance for SIROF electrodes (but not Pt), suggesting a reliable measurement of in vivo degradation.We observed a new degradation type, primarily occurring on stimulated electrodes ("pockmarked" vs "cracked") electrodes; however, tip metalization damage was not significantly higher due to stimulation or amount of charge. Physical damage was centralized to specific regions of an array often with differences between outer and inner electrodes. This is consistent with degradation due to contact with the biologic milieu, influenced by variations in initial manufactured state. From our data, we hypothesize that erosion of the silicon shank often precedes damage to the tip metal, accelerating damage to the electrode / tissue interface. Conclusions: These findings link quantitative measurements, such as impedance, to the physical condition of the microelectrodes and their capacity to record and stimulate. These data could lead to improved manufacturing or novel electrode designs to improve long-term performance of BMIs making them are vitally important as multi-year clinical trials of BMIs are becoming more common.

2.
J Neural Eng ; 21(4)2024 Aug 28.
Article in English | MEDLINE | ID: mdl-39134021

ABSTRACT

Objective.A crucial goal in brain-machine interfacing is the long-term stability of neural decoding performance, ideally without regular retraining. Long-term stability has only been previously demonstrated in non-human primate experiments and only in primary sensorimotor cortices. Here we extend previous methods to determine long-term stability in humans by identifying and aligning low-dimensional structures in neural data.Approach.Over a period of 1106 and 871 d respectively, two participants completed an imagined center-out reaching task. The longitudinal accuracy between all day pairs was assessed by latent subspace alignment using principal components analysis and canonical correlations analysis of multi-unit intracortical recordings in different brain regions (Brodmann Area 5, Anterior Intraparietal Area and the junction of the postcentral and intraparietal sulcus).Main results.We show the long-term stable representation of neural activity in subspaces of intracortical recordings from higher-order association areas in humans.Significance.These results can be practically applied to significantly expand the longevity and generalizability of brain-computer interfaces.Clinical TrialsNCT01849822, NCT01958086, NCT01964261.


Subject(s)
Brain-Computer Interfaces , Imagination , Movement , Parietal Lobe , Adult , Female , Humans , Male , Imagination/physiology , Movement/physiology , Parietal Lobe/physiology , Middle Aged , Single-Case Studies as Topic
3.
bioRxiv ; 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37461446

ABSTRACT

A crucial goal in brain-machine interfacing is long-term stability of neural decoding performance, ideally without regular retraining. Here we demonstrate stable neural decoding over several years in two human participants, achieved by latent subspace alignment of multi-unit intracortical recordings in posterior parietal cortex. These results can be practically applied to significantly expand the longevity and generalizability of future movement decoding devices.

SELECTION OF CITATIONS
SEARCH DETAIL