Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Radiology ; 311(3): e232677, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38916504

ABSTRACT

Background CT-derived bronchial parameters have been linked to chronic obstructive pulmonary disease and asthma severity, but little is known about these parameters in healthy individuals. Purpose To investigate the distribution of bronchial parameters at low-dose CT in individuals with healthy lungs from a Dutch general population. Materials and Methods In this prospective study, low-dose chest CT performed between May 2017 and October 2022 were obtained from participants who had completed the second-round assessment of the prospective, longitudinal Imaging in Lifelines study. Participants were aged at least 45 years, and those with abnormal spirometry, self-reported respiratory disease, or signs of lung disease at CT were excluded. Airway lumens and walls were segmented automatically. The square root of the bronchial wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10), luminal area (LA), wall thickness (WT), and wall area percentage were calculated. Associations between sex, age, height, weight, smoking status, and bronchial parameters were assessed using univariable and multivariable analyses. Results The study sample was composed of 8869 participants with healthy lungs (mean age, 60.9 years ± 10.4 [SD]; 4841 [54.6%] female participants), including 3672 (41.4%) never-smokers and 1197 (13.5%) individuals who currently smoke. Bronchial parameters for male participants were higher than those for female participants (Pi10, slope [ß] range = 3.49-3.66 mm; LA, ß range = 25.40-29.76 mm2; WT, ß range = 0.98-1.03 mm; all P < .001). Increasing age correlated with higher Pi10, LA, and WT (r2 range = 0.06-0.09, 0.02-0.01, and 0.02-0.07, respectively; all P < .001). Never-smoking individuals had the lowest Pi10 followed by formerly smoking and currently smoking individuals (3.62 mm ± 0.13, 3.68 mm ± 0.14, and 3.70 mm ± 0.14, respectively; all P < .001). In multivariable regression models, age, sex, height, weight, and smoking history explained up to 46% of the variation in bronchial parameters. Conclusion In healthy individuals, bronchial parameters differed by sex, height, weight, and smoking history; male sex and increasing age were associated with wider lumens and thicker walls. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Emrich and Varga-Szemes in this issue.


Subject(s)
Tomography, X-Ray Computed , Humans , Male , Female , Middle Aged , Tomography, X-Ray Computed/methods , Prospective Studies , Lung/diagnostic imaging , Bronchi/diagnostic imaging , Radiation Dosage , Aged , Netherlands
2.
Eur Radiol Exp ; 8(1): 63, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38764066

ABSTRACT

BACKGROUND: Emphysema influences the appearance of lung tissue in computed tomography (CT). We evaluated whether this affects lung nodule detection by artificial intelligence (AI) and human readers (HR). METHODS: Individuals were selected from the "Lifelines" cohort who had undergone low-dose chest CT. Nodules in individuals without emphysema were matched to similar-sized nodules in individuals with at least moderate emphysema. AI results for nodular findings of 30-100 mm3 and 101-300 mm3 were compared to those of HR; two expert radiologists blindly reviewed discrepancies. Sensitivity and false positives (FPs)/scan were compared for emphysema and non-emphysema groups. RESULTS: Thirty-nine participants with and 82 without emphysema were included (n = 121, aged 61 ± 8 years (mean ± standard deviation), 58/121 males (47.9%)). AI and HR detected 196 and 206 nodular findings, respectively, yielding 109 concordant nodules and 184 discrepancies, including 118 true nodules. For AI, sensitivity was 0.68 (95% confidence interval 0.57-0.77) in emphysema versus 0.71 (0.62-0.78) in non-emphysema, with FPs/scan 0.51 and 0.22, respectively (p = 0.028). For HR, sensitivity was 0.76 (0.65-0.84) and 0.80 (0.72-0.86), with FPs/scan of 0.15 and 0.27 (p = 0.230). Overall sensitivity was slightly higher for HR than for AI, but this difference disappeared after the exclusion of benign lymph nodes. FPs/scan were higher for AI in emphysema than in non-emphysema (p = 0.028), while FPs/scan for HR were higher than AI for 30-100 mm3 nodules in non-emphysema (p = 0.009). CONCLUSIONS: AI resulted in more FPs/scan in emphysema compared to non-emphysema, a difference not observed for HR. RELEVANCE STATEMENT: In the creation of a benchmark dataset to validate AI software for lung nodule detection, the inclusion of emphysema cases is important due to the additional number of FPs. KEY POINTS: • The sensitivity of nodule detection by AI was similar in emphysema and non-emphysema. • AI had more FPs/scan in emphysema compared to non-emphysema. • Sensitivity and FPs/scan by the human reader were comparable for emphysema and non-emphysema. • Emphysema and non-emphysema representation in benchmark dataset is important for validating AI.


Subject(s)
Artificial Intelligence , Pulmonary Emphysema , Tomography, X-Ray Computed , Humans , Male , Middle Aged , Female , Tomography, X-Ray Computed/methods , Pulmonary Emphysema/diagnostic imaging , Software , Sensitivity and Specificity , Lung Neoplasms/diagnostic imaging , Aged , Radiation Dosage , Solitary Pulmonary Nodule/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
3.
Diagnostics (Basel) ; 13(22)2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37998584

ABSTRACT

The aim of this phantom study was to assess the detectability and volumetric accuracy of pulmonary nodules on photon-counting detector CT (PCD-CT) at different low-dose levels compared to conventional energy-integrating detector CT (EID-CT). In-house fabricated artificial nodules of different shapes (spherical, lobulated, spiculated), sizes (2.5-10 mm and 5-1222 mm3), and densities (-330 HU and 100 HU) were randomly inserted into an anthropomorphic thorax phantom. The phantom was scanned with a low-dose chest protocol with PCD-CT and EID-CT, in which the dose with PCD-CT was lowered from 100% to 10% with respect to the EID-CT reference dose. Two blinded observers independently assessed the CT examinations of the nodules. A third observer measured the nodule volumes using commercial software. The influence of the scanner type, dose, observer, physical nodule volume, shape, and density on the detectability and volumetric accuracy was assessed by a multivariable regression analysis. In 120 CT examinations, 642 nodules were present. Observer 1 and 2 detected 367 (57%) and 289 nodules (45%), respectively. With PCD-CT and EID-CT, the nodule detectability was similar. The physical nodule volumes were underestimated by 20% (range 8-52%) with PCD-CT and 24% (range 9-52%) with EID-CT. With PCD-CT, no significant decrease in the detectability and volumetric accuracy was found at dose reductions down to 10% of the reference dose (p > 0.05). The detectability and volumetric accuracy were significantly influenced by the observer, nodule volume, and a spiculated nodule shape (p < 0.05), but not by dose, CT scanner type, and nodule density (p > 0.05). Low-dose PCD-CT demonstrates potential to detect and assess the volumes of pulmonary nodules, even with a radiation dose reduction of up to 90%.

4.
PLoS One ; 18(6): e0287383, 2023.
Article in English | MEDLINE | ID: mdl-37327210

ABSTRACT

Predicted lung volumes based on the Global Lung Function Initiative (GLI) model are used in pulmonary disease detection and monitoring. It is unknown how well the predicted lung volume corresponds with computed tomography (CT) derived total lung volume (TLV). The aim of this study was to compare the GLI-2021 model predictions of total lung capacity (TLC) with CT-derived TLV. 151 female and 139 male healthy participants (age 45-65 years) were consecutively selected from a Dutch general population cohort, the Imaging in Lifelines (ImaLife) cohort. In ImaLife, all participants underwent low-dose, inspiratory chest CT. TLV was measured by an automated analysis, and compared to predicted TLC based on the GLI-2021 model. Bland-Altman analysis was performed for analysis of systematic bias and range between limits of agreement. To further mimic the GLI-cohort all analyses were repeated in a subset of never-smokers (51% of the cohort). Mean±SD of TLV was 4.7±0.9 L in women and 6.2±1.2 L in men. TLC overestimated TLV, with systematic bias of 1.0 L in women and 1.6 L in men. Range between limits of agreement was 3.2 L for women and 4.2 L for men, indicating high variability. Performing the analysis with never-smokers yielded similar results. In conclusion, in a healthy cohort, predicted TLC substantially overestimates CT-derived TLV, with low precision and accuracy. In a clinical context where an accurate or precise lung volume is required, measurement of lung volume should be considered.


Subject(s)
Lung Diseases , Lung , Humans , Female , Male , Middle Aged , Aged , Lung/diagnostic imaging , Lung Volume Measurements , Tomography, X-Ray Computed/methods , Total Lung Capacity
5.
Br J Radiol ; 96(1144): 20220709, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36728829

ABSTRACT

OBJECTIVE: To evaluate detectability and semi-automatic diameter and volume measurements of pulmonary nodules in ultralow-dose CT (ULDCT) vs regular-dose CT (RDCT). METHODS: Fifty patients with chronic obstructive pulmonary disease (COPD) underwent RDCT on 64-multidetector CT (120 kV, filtered back projection), and ULDCT on third-generation dual source CT (100 kV with tin filter, advanced modeled iterative reconstruction). One radiologist evaluated the presence of nodules on both scans in random order, with discrepancies judged by two independent radiologists and consensus reading. Sensitivity of nodule detection on RDCT and ULDCT was compared to reader consensus. Systematic error in semi-automatically derived diameter and volume, and 95% limits of agreement (LoA) were evaluated. Nodule classification was compared by κ statistics. RESULTS: ULDCT resulted in 83.1% (95% CI: 81.0-85.2) dose reduction compared to RDCT (p < 0.001). 45 nodules were present, with diameter range 4.0-25.3 mm and volume range 16.0-4483.0 mm3. Detection sensitivity was non-significant (p = 0.503) between RDCT 88.8% (95% CI: 76.0-96.3) and ULDCT 95.5% (95% CI: 84.9-99.5). No systematic bias in diameter measurements (median difference: -0.2 mm) or volumetry (median difference: -6 mm3) was found for ULDCT compared to RDCT. The 95% LoA for diameter and volume measurements were ±3.0 mm and ±33.5%, respectively. κ value for nodule classification was 0.852 for diameter measurements and 0.930 for volumetry. CONCLUSION: ULDCT based on Sn100 kV enables comparable detectability of solid pulmonary nodules in COPD patients, at 83% reduced radiation dose compared to RDCT, without relevant difference in nodule measurement and size classification. ADVANCES IN KNOWLEDGE: Pulmonary nodule detectability and measurements in ULDCT are comparable to RDCT.


Subject(s)
Lung Neoplasms , Multiple Pulmonary Nodules , Pulmonary Disease, Chronic Obstructive , Humans , Lung Neoplasms/diagnostic imaging , Multidetector Computed Tomography , Multiple Pulmonary Nodules/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...