Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Publication year range
3.
Anal Chim Acta ; 767: 88-96, 2013 Mar 12.
Article in English | MEDLINE | ID: mdl-23452791

ABSTRACT

A simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) method has been developed for the determination of seven benzodiazepines (alprazolam, bromazepam, clonazepam, diazepam, lorazepam, lormetazepam and tetrazepam) in human plasma samples. Chloroform and methanol were used as extractant and disperser solvents, respectively. The influence of several variables (e.g., type and volume of dispersant and extraction solvents, pH, ultrasonic time and ionic strength) was carefully evaluated and optimized, using an asymmetric screening design 3(2)4(2)//16. Analysis of extracts was performed by ultra-performance liquid chromatography coupled with photodiode array detection (UPLC-PDA). Under the optimum conditions, two reversed-phases, Shield RP18 and C18 columns were successfully tested, obtaining good linearity in a range of 0.01-5µgmL(-1), with correlation coefficients r>0.996. Quantification limits ranged between 4.3-13.2ngmL(-1) and 4.0-14.8ngmL(-1), were obtained for C18 and Shield RP18 columns, respectively. The optimized method exhibited a good precision level, with relative standard deviation values lower than 8%. The recoveries studied at two spiked levels, ranged from 71 to 102% for all considered compounds. The proposed method was successfully applied to the analysis of seven benzodiazepines in real human plasma samples.


Subject(s)
Benzodiazepines/blood , Liquid Phase Microextraction , Ultraviolet Rays , Chromatography, High Pressure Liquid/instrumentation , Humans , Liquid Phase Microextraction/instrumentation
4.
J Chromatogr A ; 1216(36): 6356-64, 2009 Sep 04.
Article in English | MEDLINE | ID: mdl-19646707

ABSTRACT

A simple, rapid and efficient method, ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME), has been developed for the first time for the determination of 18 polycyclic aromatic hydrocarbons (PAHs) in water samples. The chemical affinity between the ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate) and the analytes permits the extraction of the PAHs from the sample matrix also allowing their preconcentration. Thus, this technique combines extraction and concentration of the analytes into one step and avoids using toxic chlorinated solvents. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, extraction time, dispersion stage, centrifuging time and ionic strength, were optimised. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection (Flu). The optimised method exhibited a good precision level with relative standard deviation values between 1.2% and 5.7%. Quantification limits obtained for all of these considered compounds (between 0.1 and 7 ng L(-1)) were well below the limits recommended in the EU. The extraction yields for the different compounds obtained by IL-DLLME, ranged from 90.3% to 103.8%. Furthermore, high enrichment factors (301-346) were also achieved. The extraction efficiency of the optimised method is compared with that achieved by liquid-liquid extraction. Finally, the proposed method was successfully applied to the analysis of PAHs in real water samples (tap, bottled, fountain, well, river, rainwater, treated and raw wastewater).


Subject(s)
Ionic Liquids , Microchemistry/methods , Polycyclic Aromatic Hydrocarbons/analysis , Water Pollutants, Chemical/analysis , Analytic Sample Preparation Methods , Chromatography, High Pressure Liquid , Imidazoles , Osmolar Concentration , Rain/chemistry , Reproducibility of Results , Rivers/chemistry , Solvents , Time Factors , Water/chemistry
5.
Anal Bioanal Chem ; 387(7): 2559-67, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17268774

ABSTRACT

A microwave-assisted sample preparation (MASP) procedure was developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) in sewage sludge and soil samples. The procedure involved the simultaneous microwave-assisted extraction of PAHs with n-hexane and the hydrolysis of samples with methanolic potassium hydroxide. Because of the complex nature of the samples, the extracts were submitted to further cleaning with silica and Florisil solid-phase extraction cartridges connected in series. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-cd]pyrene, were considered in the study. Quantification limits obtained for all of these compounds (between 0.4 and 14.8 microg kg(-1) dry mass) were well below of the limits recommended in the USA and EU. Overall recovery values ranged from 60 to 100%, with most losses being due to evaporation in the solvent exchange stages of the procedure, although excellent extraction recoveries were obtained. Validation of the accuracy was carried out with BCR-088 (sewage sludge) and BCR-524 (contaminated industrial soil) reference materials.


Subject(s)
Chromatography/methods , Polycyclic Aromatic Hydrocarbons/analysis , Saponins/chemistry , Chromatography, High Pressure Liquid , Hexanes/chemistry , Hydrolysis , Hydroxides/chemistry , Microwaves , Potassium Compounds/chemistry , Reproducibility of Results , Sewage , Solid Phase Extraction , Solvents , Spectrometry, Fluorescence/methods
SELECTION OF CITATIONS
SEARCH DETAIL