Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Transpl Int ; 36: 11331, 2023.
Article in English | MEDLINE | ID: mdl-37680646

ABSTRACT

The European Society of Organ Transplantation (ESOT) strives to promote equity, diversity, and inclusion (EDI) across all its activities. We surveyed the transplant community's experiences and perspectives regarding EDI within ESOT as an organization and its educational activities, and research in general. A total of 299 respondents completed the questionnaire. About half agreed that ESOT's Executive Committee, Council, and Sections/Committees are diverse and inclusive (51%) and that ESOT promotes EDI in its live and digital educational activities (54%). Forty percent of respondents agreed that scientific and clinical trials in the field of transplantation are diverse and inclusive. Despite the wide distribution of the survey, most of the respondents self-identified as White and were either physician or surgeon. However, the results contribute a unique insight into the experiences and perspectives of the transplantation community regarding EDI. Whilst ESOT is committed to the principles of EDI, perceptions and the high number of proposals show the apparent need to prioritize efforts to embed EDI across ESOT and transplantation science. These data should constitute a starting point for change and provide guidance for future efforts to promote EDI within the transplantation community.


Subject(s)
Organ Transplantation , Surgeons , Transplants , Humans , Diversity, Equity, Inclusion
2.
Transplant Rev (Orlando) ; 31(3): 172-179, 2017 07.
Article in English | MEDLINE | ID: mdl-28259374

ABSTRACT

We reviewed the evidence for ex-vivo Supplemental Oxygen during Hypothermic preservation (SOH) for deceased donor kidneys. Bibliographic databases were searched for human and animal studies of SOH in kidney transplantation reporting on patient or animal survival rate, discard rate, technical complications or renal function outcomes. We make special reference to a specific subgroup: supplemental oxygen applied during cold perfusion, referred to as Hypothermic Oxygenated Perfusion (HOP). Four human and 25 animal studies were identified. The data present conflicting results but suggest that the effects of oxygen on restoring kidney function during preservation may be of value for DCD kidneys and/or kidneys that have undergone a period of hypotension, warm ischemia or poor perfusion in the donor. There is very little information available from human or animal studies. This work highlights to the transplant community that far more high quality clinical studies are required to understand this technology and its role before widespread clinical introduction.


Subject(s)
Kidney Transplantation , Organ Preservation , Oxygen/therapeutic use , Humans
3.
BJS Open ; 1(4): 97-105, 2017 Aug.
Article in English | MEDLINE | ID: mdl-29951611

ABSTRACT

BACKGROUND: Clinical practice guidelines (CPGs) are widely used to inform the development of protocols for clinical management. Previous work has demonstrated that the quality of CPGs varies widely. This systematic review aimed to determine the quality of CPGs in kidney transplantation in the UK. METHODS: CPGs in kidney transplantation published between 2010 and 2017 were identified through searches of MEDLINE, NHS NICE Evidence, and websites of relevant UK societies. Using the Appraisal of Guidelines for Research and Evaluation (AGREE) II tool, three appraisers rated the quality of CPGs across six domains, the overall quality of each CPG, and whether it should be recommended for future use. Domain scores were calculated, and inter-rater reliability using the intraclass correlation coefficient (ICC) was reported. RESULTS: Thirteen CPGs met the inclusion criteria. The domain 'clarity of presentation' scored highest, followed closely by 'scope and purpose'. The poorest scoring domains were 'applicability' and 'editorial independence'. Editorial independence also had the widest range of scores. Of the 13 CPGs, one was not recommended for future use, seven were recommended for use with modifications, and five for future use with no need for modification. Mean overall CPG quality was 5 (range 3-6) of a maximum score of 7, and mean inter-rater reliability was substantial with an ICC of 0·71. CONCLUSION: UK CPGs scored satisfactorily, although with wide variation in how well each domain scored both within and across CPGs. The quality of UK CPGs can still be improved.

4.
Am J Transplant ; 16(9): 2545-55, 2016 09.
Article in English | MEDLINE | ID: mdl-26946212

ABSTRACT

The increased demand for organs has led to the increased usage of "higher risk" kidney and liver grafts. These grafts from donation after circulatory death or expanded criteria donors are more susceptible to preservation injury and have a higher risk of unfavorable outcomes. Dynamic, instead of static, preservation could allow for organ optimization, offering a platform for viability assessment, active organ repair and resuscitation. Ex situ machine perfusion and in situ regional perfusion in the donor are emerging as potential tools to preserve and resuscitate vulnerable grafts. Preclinical findings have ignited clinical organ preservation research that investigates dynamic preservation, its various modes (continuous, preimplantation) and temperatures (hypo-, sub, or normothermic). This review outlines the current status of dynamic preservation of kidney and liver grafts and describes ongoing research and emerging clinical trials.


Subject(s)
Graft Survival , Kidney Transplantation/trends , Liver Transplantation/trends , Organ Preservation/methods , Resuscitation , Tissue Donors/supply & distribution , Animals , Humans , Organ Preservation Solutions
5.
Neurourol Urodyn ; 26(3): 362-71, 2007.
Article in English | MEDLINE | ID: mdl-17304528

ABSTRACT

AIMS: Due to their contribution to modulation of intra-abdominal pressure (IAP) and stiffness of the sacroiliac joints, the pelvic floor muscles (PFM) have been argued to provide a contribution to control of the lumbar spine and pelvis. Furthermore, as IAP is modulated during respiration this is likely to be accompanied by changes in PFM activity. METHODS: In order to evaluate the postural and respiratory function of the PFM, recordings of anal and vaginal electromyographic activity (EMG) were made with surface electrodes during single and repetitive arm movements that challenge the stability of the spine. EMG recordings were also made during respiratory tasks: quiet breathing and breathing with increased dead-space to induce hypercapnoea. RESULTS: EMG activity of the PFM was increased in advance of deltoid muscle activity as a component of the pre-programmed anticipatory postural activity. This activity was independent of the direction of arm movement. During repetitive movements, PFM EMG was tonic with phasic bursts at the frequency of arm movement. This activity was related to the peak acceleration of the arm, and therefore the amplitude of the reactive forces imposed on the spine. Respiratory activity was observed for the anal and vaginal EMG and was primarily expiratory. When subjects moved the arm repetitively while breathing, PFM EMG was primarily modulated in association with arm movement with little respiratory modulation. CONCLUSIONS: This study provides evidence that the PFM contribute to both postural and respiratory functions.


Subject(s)
Muscle, Skeletal/physiology , Pelvic Floor/physiology , Posture/physiology , Respiratory Mechanics/physiology , Adult , Anal Canal , Arm , Electromyography , Female , Humans , Hypercapnia/physiopathology , Male , Middle Aged , Motor Activity/physiology , Movement/physiology , Muscle Contraction/physiology , Respiratory Dead Space/physiology , Vagina
6.
Muscle Nerve ; 27(6): 682-92, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12766979

ABSTRACT

To investigate the ability of ultrasonography to estimate muscle activity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a noninvasive method of detecting isometric muscle contractions of certain individual muscles.


Subject(s)
Muscle Contraction/physiology , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Adult , Electromyography , Female , Humans , Male , Middle Aged , Muscle Fibers, Skeletal/diagnostic imaging , Muscle Fibers, Skeletal/physiology , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...