A person's well-being and health are greatly affected by disorders of sleep and wakefulness. It is of the utmost importance to diagnose and treat such conditions, since the associated daytime sleepiness is a major risk factor for accidents. Early establishment of the correct diagnosis paves the way to achieving an excellent therapeutic outcome. Health-economic requirements of appropriateness and necessity mandate the specific use of cost- and time-intensive examinations in the sleep laboratory. In accordance with the guidelines for "non-restorative sleep", severe and chronic sleep disorders can be diagnosed outside the sleep lab if the underlying cause can already be identified on the basis of the patient's history. Such is usually the case in sleep disorders caused by external influences, disturbed circadian rhythm or pre-existing neurological, psychiatric or internal disorders. Standardized questionnaires are used to record and evaluate the patient's complaints, and vigilance testing to assess impaired sustained attention during the day. Excessive daytime sleepiness is quantified by the multiple sleep latency test (MSLT). In the case of some disorders such as apnoea, or periodic leg movements, simplified ambulatory methods have been developed to enable their detection at an early stage. The gold standard for the diagnosis of sleep disorders in the sleep lab is cardiorespiratory polysomnography. The relevant biosignals for the assessment of sleep, respiration, heart function, the cardiovascular system and movement are well established. Some of the sensors employed need further improvement. Numerous methods for signal analysis are still undergoing development, and currently available automatic evaluation systems are not yet reliable enough to obviate the need for manual interpretation.


Subject(s)
Sleep Wake Disorders/diagnosis , Ambulatory Care/economics , Cost-Benefit Analysis , Diagnosis, Differential , Humans , Polysomnography/economics , Sleep Wake Disorders/economics , Sleep Wake Disorders/etiology
2.
Biomed Tech (Berl) ; 47(6): 146-50, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12149800

ABSTRACT

The classic auscultation with stethoscope is the established clinical method for the detection of lung diseases. The interpretation of the sounds depends on the experience of the investigating physician. Therefore, a new computer-based method has been developed to classify breath sounds from digital lung sound recordings. Lung sounds of 11 patients with one-sided pneumonia and bronchial breathing were recorded on both the pneumonia side and on contralateral healthy side simultaneously using two microphones. The spectral power for the 300-600 Hz frequency band was computed for four respiratory cycles and normalized. For each breath, the ratio R between the time-segments (duration = 0.1 s) with the highest inspiratory and highest expiratory flow was calculated and averaged. We found significant differences in R between the pneumonia side (R = 1.4 +/- 1.3) and the healthy side (R = 0.5 +/- 0.5; p = 0.003 Wilcoxon-test) of lung. In 218 healthy volunteers we found R = 0.3 +/- 0.2 as a reference-value. The differences of ratio R (delta R) between the pneumonia side and the healthy side (delta R = 1.0 +/- 0.9) were significantly higher compared to follow-up studies after recovery (delta R = 0.0 +/- 0.1, p = 0.005 Wilcoxon-test). The computer based detection of bronchial breathing can be considered useful as part of a quantitative monitoring of patients at risk to develop pneumonia.


Subject(s)
Auscultation , Diagnosis, Computer-Assisted/instrumentation , Pneumonia/diagnosis , Respiratory Sounds/physiology , Signal Processing, Computer-Assisted/instrumentation , Bronchi/physiopathology , Follow-Up Studies , Fourier Analysis , Humans , Pneumonia/physiopathology , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL
...