1.
IEEE Trans Radiat Plasma Med Sci ; 6(4): 393-403, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35372739

ABSTRACT

The best crystal identification (CI) algorithms proposed so far for phoswich detectors are based on adaptive filtering and pulse shape discrimination (PSD). However, these techniques require free running analog to digital converters, which is no longer possible with the ever increasing pixelization of new detectors. We propose to explore the dual-threshold time-over-threshold (ToT) technique, used to measure events energy and time of occurence, as a more robust solution for crystal identification with broad energy windows in phoswich detectors. In this study, phoswich assemblies made of various combinations of LGSO and LYSO scintillators with decay times in the range 30 to 65 ns were investigated for the LabPET II detection front-end. The electronic readout is based on a 4 × 8 APD array where pixels are individually coupled to charge sensitive preamplifiers followed by first order CR-RC shapers with 75 ns peaking time. Crystal identification data were sorted out based on the measurements of likeliness between acquired signals and a time domain model of the analog front-end. Results demonstrate that crystal identification can be successfully performed using a dual-threshold ToT scheme with a discrimination accuracy of 99.1% for LGSO (30 ns)/LGSO (45 ns), 98.1% for LGSO (65 ns)/LYSO (40 ns) and 92.1% for LYSO (32 ns)/LYSO (47 ns), for an energy window of [350-650] keV. Moreover, the method shows a discrimination accuracy >97% for the two first pairs and ~90% for the last one when using a wide energy window of [250-650] keV.

2.
Phys Med Biol ; 66(6): 065019, 2021 03 09.
Article in English | MEDLINE | ID: mdl-33412542

ABSTRACT

The LabPET II is a new positron emission tomography technology platform designed to achieve submillimetric spatial resolution imaging using fully pixelated avalanche photodiodes-based detectors and highly integrated parallel front-end processing electronics. The detector was designed as a generic building block to develop devices for preclinical imaging of small to mid-sized animals and for clinical imaging of the human brain. The aim of this work is to assess the physical characteristics and imaging performance of the mouse version of LabPET II scanner following the NEMA NU4-2008 standard and using high resolution phantoms and in vivo imaging applications. A reconstructed spatial resolution of 0.78 mm (0.5 µ l) is measured close to the center of the radial field of view. With an energy window of 350 650 keV, the system absolute sensitivity is 1.2% and its maximum noise equivalent count rate reaches 61.1 kcps at 117 MBq. Submillimetric spatial resolution is achieved in a hot spot phantom and tiny bone structures were resolved with unprecedented contrast in the mouse. These results provide convincing evidence of the capabilities of the LabPET II technology for biomolecular imaging in preclinical research.


Subject(s)
Phantoms, Imaging , Positron-Emission Tomography/methods , Animals , Brain , Calibration , Electronics , Equipment Design , Fluorodeoxyglucose F18 , Humans , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Mice , Reproducibility of Results , Sensitivity and Specificity , Whole Body Imaging/methods
3.
Phys Med Biol ; 62(2): 669-683, 2017 01 21.
Article in English | MEDLINE | ID: mdl-28050968

ABSTRACT

Individually coupled scintillation detectors used in positron emission tomography (PET) imaging suffer from important signal losses due to the suboptimal light collection from crystals. As only a fraction of the light is generally extracted from long and thin scintillators, it is important to identify and understand the predominant causes of signal loss in order to eventually recover it. This simulation study investigates the multiple factors affecting the light transport in high-aspect ratio LYSO scintillators wrapped in specular reflectors through a full factorial design. By exploring various combinations of crystal geometry, readout conditions and wrapping conditions, it was found that an optimum light output can only be achieved through a careful selection of highly reflective material along with high-transmittance optical adhesive used to bond the reflector. Decreasing the adhesive thickness was also found to have a positive outcome in most explored configurations, however to a much lesser extent. Suboptimal reflectivity and adhesive transmittance also lead to an asymmetric light output distribution dependent on the depth of interaction of the radiation, potentially degrading energy resolution. By identifying the factors causing the most significant scintillation light losses through a factorial design, the most promising detector configurations have been identified in the quest for optimal light collection from scintillators.


Subject(s)
Light , Monte Carlo Method , Positron-Emission Tomography/instrumentation , Scintillation Counting/instrumentation , Humans , Positron-Emission Tomography/methods , Scintillation Counting/methods