J Pediatr ; 235: 75-82.e1, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33857466

ABSTRACT

OBJECTIVES: To evaluate cerebral tissue oxygenation (cTOI) and cerebral perfusion in preterm infants in supine vs prone positions. STUDY DESIGN: Sixty preterm infants, born before 32 weeks of gestation, were enrolled; 30 had bronchopulmonary dysplasia (BPD, defined as the need for respiratory support and/or supplemental oxygen at 36 weeks of postmenstrual age). Cerebral perfusion, cTOI, and polysomnography were measured in both the supine and prone position with the initial position being randomized. Infants with a major intraventricular hemorrhage or major congenital abnormality were excluded. RESULTS: Cerebral perfusion was unaffected by position or BPD status. In the BPD group, the mean cTOI was higher in the prone position compared with the supine position by a difference of 3.27% (P = .03; 95% CI 6.28-0.25) with no difference seen in the no-BPD group. For the BPD group, the burden of cerebral hypoxemia (cumulative time spent with cTOI <55%) was significantly lower in the prone position (23%) compared with the supine position (29%) (P < .001). In those without BPD, position had no effect on cTOI. CONCLUSIONS: In preterm infants with BPD, the prone position improved cerebral oxygenation and reduced cerebral hypoxemia. These findings may have implications for positioning practices. Further research will establish the impact of position on short- and long-term developmental outcomes.


Subject(s)
Brain/metabolism , Cerebrovascular Circulation/physiology , Infant, Premature/physiology , Oxygen/metabolism , Prone Position/physiology , Supine Position/physiology , Bronchopulmonary Dysplasia/physiopathology , Bronchopulmonary Dysplasia/therapy , Continuous Positive Airway Pressure , Cross-Over Studies , Humans , Hypoxia, Brain/physiopathology , Hypoxia, Brain/prevention & control , Infant, Newborn , Intensive Care Units, Neonatal , Oxygen Inhalation Therapy , Prospective Studies
2.
PLoS One ; 11(4): e0154034, 2016.
Article in English | MEDLINE | ID: mdl-27116224

ABSTRACT

BACKGROUND: Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or 'rainout' from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators. OBJECTIVE: To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode. DESIGN: Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected. RESULTS: Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from 'specific' (tube occluded) to 'ambiguous' (Safety valve open). Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O. CONCLUSIONS: This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode.


Subject(s)
Continuous Positive Airway Pressure/instrumentation , Equipment Failure , Respiration, Artificial/instrumentation , Security Measures , Water , Humans , Infant, Newborn