Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Med (Lausanne) ; 8: 671658, 2021.
Article in English | MEDLINE | ID: mdl-34124099

ABSTRACT

Unexpected difficult airway management can cause significant morbidity and mortality in patients admitted for elective procedures. Ultrasonography is a promising tool for perioperative airway assessment, nevertheless it is still unclear which sonographic parameters are useful predictors of difficult laryngoscopy and tracheal intubation. To determine the ultrasonographic predictors of a difficult airway that could be applied for routine practice, a systematic review and meta-analysis was conducted. Literature search was performed on PubMED, Web of Science and Embase using the selected keywords. Human primary studies, published in English with the use of ultrasonography to prediction of difficult laryngoscopy or tracheal intubation were included. A total of 19 articles (4,570 patients) were analyzed for the systematic review and 12 articles (1,141 patients) for the meta-analysis. Standardized mean differences between easy and difficult laryngoscopy groups were calculated and the parameter effect size quantified. A PRISMA methodology was used and the critical appraisal tool from Joanna Briggs Institute was applied. Twenty-six sonographic parameters were studied. The overall effect of the distance from skin to hyoid bone (p = 0.02); skin to epiglottis (p = 0.02); skin to the anterior commissure of vocal cords (p = 0.02), pre-epiglottis space to distance between epiglottis and midpoint between vocal cords (p = 0.01), hyomental distance in neutral (p < 0.0001), and extended (p = 0.0002) positions and ratio of hyomental distance in neutral to extended (p = 0.001) was significant. This study shows that hyomental distance in the neutral position is the most reliable parameter for pre-operative airway ultrasound assessment. The main limitations of the study are the small sample size, heterogeneity of studies, and absence of a standardized ultrasonographic evaluation method [Registered at International prospective register of systematic reviews (PROSPERO): number 167931].

2.
ACS Omega ; 5(21): 12057-12066, 2020 Jun 02.
Article in English | MEDLINE | ID: mdl-32548384

ABSTRACT

Alzheimer's disease (AD) is one of the most common forms of dementia affecting millions of people worldwide. Currently, an easy and effective form of diagnosis is missing, which significantly hinders a possible improvement of the patient's quality of life. In this context, biosensors emerge as a future solution, opening the doors for preventive medicine and allowing the premature diagnosis of numerous pathologies. This work presents a pioneering biosensor that combines a bottom-up design approach using paper as a platform for the electrochemical recognition of peptide amyloid ß-42 (Aß-42), a biomarker for AD present in blood, associated with visible differences in the brain tissue and responsible for the formation of senile plaques. The sensor layer relies on a molecularly imprinted polymer as a biorecognition element, created on the carbon ink electrode's surface by electropolymerizing a mixture of the target analyte (Aß-42) and a monomer (O-phenylenediamine) at neutral pH 7.2. Next, the template molecule was removed from the polymeric network by enzymatic and acidic treatments. The vacant sites so obtained preserved the shape of the imprinted protein and were able to rebind the target analyte. Morphological and chemical analyses were performed in order to control the surface modification of the materials. The analytical performance of the biosensor was evaluated by an electroanalytical technique, namely, square wave voltammetry. For this purpose, the analytical response of the biosensor was tested with standard solutions ranging from 0.1 ng/mL to 1 µg/mL of Aß-42. The linear response of the biosensor went down to 0.1 ng/mL. Overall, the developed biosensor offered numerous benefits, such as simplicity, low cost, reproducibility, fast response, and repeatability less than 10%. All together, these features may have a strong impact in the early detection of AD.

SELECTION OF CITATIONS
SEARCH DETAIL
...