1.
Article in English | MEDLINE | ID: mdl-35511720

ABSTRACT

High-flow nasal cannula (HFNC) is extensively used for acute respiratory failure. However, questions remain regarding its physiological effects. We explored 1) whether HFNC produced similar effects to continuous positive airway pressure (CPAP); 2) possible explanations of respiratory rate changes; 3) the effects of mouth opening. Two studies were conducted: a bench study using a manikin's head with lungs connected to a breathing simulator while delivering HFNC flow rates from 0 to 60L/min; a physiological cross-over study in 10 healthy volunteers receiving HFNC (20 to 60L/min) with the mouth open or closed and CPAP 4cmH2O delivered through face-mask. Nasopharyngeal and esophageal pressures were measured; tidal volume and flow were estimated using calibrated electrical impedance tomography. In the bench study, nasopharyngeal pressure at end-expiration reached 4cmH2O with HFNC at 60L/min, while tidal volume decreased with increasing flow. In volunteers with HFNC at 60L/min, nasopharyngeal pressure reached 6.8cmH2O with mouth closed and 0.8cmH2O with mouth open; p<0.001. When increasing HFNC flow, respiratory rate decreased by lengthening expiratory time, tidal volume did not change, and effort decreased (pressure-time product of the respiratory muscles); at 40L/min, effort was equivalent between CPAP and HFNC40L/min and became lower at 60L/min (p=0.045). During HFNC with mouth closed, and not during CPAP, resistance to breathing was increased, mostly during expiration. In conclusion, mouth closure during HFNC induces a positive nasopharyngeal pressure proportional to flow rate and an increase in expiratory resistance that might explain the prolonged expiration and reduction in respiratory rate and effort, and contribute to physiological benefits.

2.
Anaesth Crit Care Pain Med ; 39(6): 825-831, 2020 12.
Article in English | MEDLINE | ID: mdl-33080407

ABSTRACT

INTRODUCTION: Transthoracic lung ultrasound can assess atelectasis reversal and is considered as unable to detect associated hyperdistention. In this study, we describe an ultrasound pattern highly suggestive of pulmonary hyperdistention. METHODS: Eighteen patients with normal lungs undergoing lower abdominal surgery were studied. Electrical impedance tomography was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment manoeuvre was performed. Positive-end expiratory pressure (PEEP) titration was then obtained during a descending trial - 20, 18, 16, 14, 12, 10, 8, 6 and 4cmH2O. Ultrasound and electrical impedance tomography data were collected at each PEEP level and interpreted by two independent observers. Spearman correlation test and receiving operating characteristic curve were used to compare lung ultrasound and electrical impedance tomography data. RESULTS: The number of horizontal A lines increased linearly with PEEP: from 3 (0, 5) at PEEP 4cmH2O to 10 (8, 13) at PEEP 20cmH2O. The increase number of A lines was associated with a parallel and significant decrease in intercostal space thickness (p=0.001). The lung ultrasound threshold for detecting pulmonary hyperdistention was defined as the number of A lines counted at the PEEP preceding the PEEP providing the best respiratory compliance. Six A lines was the median threshold for detecting pulmonary hyperdistention. The area under the receiving operating characteristic curve was 0.947. CONCLUSIONS: Intraoperative transthoracic lung ultrasound can detect lung hyperdistention during a PEEP descending trial. Six or more A lines detected in normally aerated regions can be considered as indicating lung hyperdistention. TRIAL REGISTRATION: NCT02314845 Registered on ClinicalTrials.gov.


Subject(s)
Positive-Pressure Respiration , Pulmonary Atelectasis , Humans , Lung/diagnostic imaging , Pilot Projects , Pulmonary Atelectasis/diagnostic imaging , Respiration, Artificial
SELECTION OF CITATIONS
SEARCH DETAIL
...