Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Am J Perinatol ; 2023 May 11.
Article in English | MEDLINE | ID: mdl-37040879

ABSTRACT

OBJECTIVE: This study aimed to examine the variation between clinician-recorded and continuously downloaded invasive blood pressure (BP). STUDY DESIGN: Prospective study where invasive BP data were downloaded every 10 seconds for the first week of life. Hourly clinician-recorded BP was recorded. Agreement between the two methods were examined. RESULTS: A total of 1,180 BP measurements were examined from 42 preterm infants with a mean (standard deviation [SD]) gestation and birthweight of 25.7 weeks (1.4) and 802 g (177) respectively. The mean (SD) bias was -0.11 mm Hg (3.17), but the 95% limits of agreement (LOA) varied between -6.3 and +6.1 mm Hg. Inotrope usage was significantly higher for BP measurements that fell in the 5% outliers when compared with those that fell within the 95% LOA (62.7 vs. 44.6%, p = 0.006). CONCLUSION: Clinicians showed no systematic bias to over- or underrecord BP, but some of the greatest differences were found in infants receiving inotropes. KEY POINTS: · BP is a commonly recorded cardiovascular parameter in the neonatal intensive care unit.. · Invasively measured BP remains the gold standard.. · Clinician-recorded BP showed no systematic bias in over-or underrecording invasive BP..

4.
Pediatrics ; 150(1)2022 07 01.
Article in English | MEDLINE | ID: mdl-35425990

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 infections are uncommon in newborn infants. This report describes possible in utero transmission of the B.1.1.7 (alpha) variant in a preterm infant born at 31 weeks' gestational age who presented with severe respiratory disease. The infant was treated with high-frequency oscillatory ventilation, antiviral medications, and corticosteroids and transitioned to noninvasive respiratory support on day 33. By day 63, she was off positive pressure support and breathing room air and she was discharged from the hospital on day 70. She demonstrated normal growth and development at a 6-month follow-up visit. Placental histopathology revealed placentitis characterized by loss of intervillous spaces resulting from fibrin deposition and inflammatory cell infiltration. Optimum management strategies for treating infants with severe acute respiratory syndrome coronavirus 2 infection have yet to be determined.


Subject(s)
COVID-19 , Infant, Newborn, Diseases , Pregnancy Complications, Infectious , Female , Humans , Infant , Infant, Newborn , Infant, Premature , Placenta , Pregnancy , Pregnancy Complications, Infectious/diagnosis , Pregnancy Complications, Infectious/therapy , SARS-CoV-2
5.
BMJ Case Rep ; 14(3)2021 Mar 09.
Article in English | MEDLINE | ID: mdl-33687939

ABSTRACT

We present a case of an extreme preterm infant (Baby X) born at 24-week gestation. The echocardiogram showed evidence of hypertrophic cardiomyopathy (HCM) and a patent ductus arteriosus (PDA). There are a number of well-known causes of neonatal HCM including genetic, metabolic and endocrine. PDA is commonly present in preterm infants, and this can contribute to cardiac remodelling and result in cardiac changes mimicking HCM. Furthermore, medications such as steroids can also cause HCM through various mechanisms. A careful consideration of all the different aetiologies for HCM is important for appropriate management of such cases. This report examines the evidence in the literature for the above differential diagnoses and highlights the challenges in diagnosing the underlying cause of HCM in a preterm infant.


Subject(s)
Cardiomyopathy, Hypertrophic , Ductus Arteriosus, Patent , Persistent Fetal Circulation Syndrome , Cardiomyopathy, Hypertrophic/diagnostic imaging , Ductus Arteriosus, Patent/diagnosis , Ductus Arteriosus, Patent/diagnostic imaging , Gestational Age , Humans , Infant , Infant, Extremely Premature , Infant, Newborn
6.
Acta Paediatr ; 110(4): 1157-1165, 2021 04.
Article in English | MEDLINE | ID: mdl-33145798

ABSTRACT

AIM: The aim of this study was to determine carotid blood flow volume, a surrogate for cerebral blood flow, using Doppler ultrasound in extremely preterm infants. METHODS: In infants <29 weeks, right common carotid artery flow volume (RCCAF) was calculated from vessel diameter and intensity-weighted mean velocity measured using Doppler ultrasound on days 1 and 3. In addition, left ventricular output (LVO), ductus arteriosus characteristics and invasive mean arterial blood pressure (MABP) were obtained. RESULTS: Sixty infants with mean gestation of 25.8 weeks were studied. The median RCCAF increased from 12 (IQR 9-15) mL/kg/min on day 1, to 14 (IQR 12-18) mL/kg/min on day 3 (p = 0.007). RCCAF was positively correlated with invasive MABP on days 1 and 3. RCCAF significantly correlated with LVO in infants with closing or closed ductus arteriosus on day 1. Using multiple regression analysis, RCCAF was significantly associated with invasive MABP on day 1 and to inotropic treatment on day 3. CONCLUSION: Doppler ultrasound can be used to measure RCCAF in extremely preterm infants receiving intensive care. RCCAF increased during the first three days and was positively related to invasive MABP on day 1. Values were lower than previously described in more mature infants. CLINICAL TRIAL REGISTRATION: ISRCTN 83507686.


Subject(s)
Ductus Arteriosus, Patent , Infant, Extremely Premature , Blood Flow Velocity , Carotid Artery, Common/diagnostic imaging , Cerebrovascular Circulation , Ductus Arteriosus, Patent/diagnostic imaging , Hemodynamics , Humans , Infant , Infant, Newborn
7.
Am J Perinatol ; 38(14): 1480-1482, 2021 12.
Article in English | MEDLINE | ID: mdl-32604447

ABSTRACT

OBJECTIVE: This study aimed to compare left ventricular outflow tract (LVOT) diameter measurements using two-dimensional (2D) echocardiography at the sino-tubular junction (STJ) and at the aortic valve (AV) hinges in newborn infants. STUDY DESIGN: This is a retrospective study in a tertiary neonatal unit where infants underwent echocardiography for evaluation of murmur or as part of cardiovascular assessment. Three consecutive cardiac cycles were chosen to measure the LVOT diameter in end systole at the STJ and at the AV hinges. Bias and levels of agreement were examined using Bland-Altman plot. Intraobserver variability was examined using intraclass correlation. RESULTS: A total of 366 measurements were obtained from 61 infants with a mean (standard deviation) gestation and birth weight of 33.4 (6.9) weeks and 2,181 (1369) g, respectively. There was good correlation between the LVOT diameter measurements using the STJ and AV hinges (r = 0.958, p < 0.001). The mean (standard deviation and 95% confidence interval) bias between LVOT diameter measurements using STJ and AV hinges were 0.93 (0.45 and 0.06-1.81) mm. There was good intraobserver variability between the measurements using both methods. CONCLUSION: Using 2D echocardiography, LVOT measurements using the STJ tend to be higher when compared with LVOT measurements using the AV hinges. KEY POINTS: · Echocardiographic assessment of left ventricular output is undertaken frequently.. · Left ventricular outflow tract can be measured at the aortic valve hinges, sinus of valsalva, or sino-tubular junction.. · Left ventricular outflow tract measured at the sino-tubular junction tends to higher when compared with aortic valve.


Subject(s)
Aortic Valve/anatomy & histology , Echocardiography , Heart Ventricles/diagnostic imaging , Aortic Valve/diagnostic imaging , Cardiac Output , Heart Ventricles/anatomy & histology , Humans , Infant , Infant, Newborn , Retrospective Studies , Ventricular Function
8.
Ultrasound ; 28(3): 145-154, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32831887

ABSTRACT

INTRODUCTION: Cerebral blood flow is increasingly monitored in preterm infants. Doppler ultrasound of the carotid artery is a widely available method but is operator dependent. Our aim was to design and produce a realistic flow phantom model of the carotid artery of preterm infants. METHODS: Data from cerebral blood flow measurements using Doppler ultrasound of the right common carotid artery from 21 premature newborn infants were used to produce a Doppler flow phantom model with three different vessel diameters. Vessel diameter, continuous and pulsatile flow volume measurements were performed by two blinded observers (with more than eight and 20 years of experience). RESULTS: Vessel diameter measurements using the phantom were underestimated by 7%. Continuous flow volume measurements were overestimated by 7% by both observers (observer 1 mean difference 1.5 ± 1.96 SD -3.3 to 6.3 ml/min versus observer 2, 1.9 ± 1.96 SD -3.6 to 7.4 ml/min). Pulsatile flow measurements were overestimated by 12.6% by observer 1 (2.7 ± 1.96 SD -0.6 to 5.9 ml/min) and by 7.8% by observer 2 (1.7 ± 1.96 SD -1.6 to 4.9 ml/min). There was good interobserver and intraobserver reliability for the majority of measurements using continuous and pulsatile flow. CONCLUSION: It is feasible to produce a realistic flow phantom model of the neonatal carotid artery of preterm infants. Diameter measurements were underestimated and flow measurements were overestimated. These errors fell within acceptable limits for in vivo measurements. If these limitations were related to materials, this could be explored using a wall-less model. The flow phantom could be utilised for research and training clinicians in measuring cerebral blood flow using the carotid artery in this vulnerable group of infants.

9.
Am J Perinatol ; 36(14): 1498-1503, 2019 12.
Article in English | MEDLINE | ID: mdl-30780185

ABSTRACT

OBJECTIVE: To evaluate the association between endotracheal tube (ETT) tip position and adverse pulmonary outcomes using chest X-ray (CXR) in extremely preterm infants in whom ETT insertion length was estimated using weight + 6 guide (adding 6 cms to the infant's weight in kg). STUDY DESIGN: CXRs of 85 infants performed in the first week were reviewed for right-sided atelectasis, air leaks, and uneven lung inflation. The first CXR was later reviewed to document the ETT tip. Regression analysis was performed to find the association between ETT tip position and adverse outcome after adjusting for other confounders. RESULTS: Forty (46%) infants had ETT tip placement between the first and second thoracic vertebrae (optimal position) compared with 45 (53%) who had the ETT tip placement outside this range (suboptimal position). Infants with suboptimal ETT were ventilated for a longer period (6.1 vs. 15.9 days; p = 0.004). The odds of adverse outcomes was 11.6 (95% confidence interval: 3.03, 44.1) times higher among infants who did not have ETT at the optimal position compared with infants who had ETT at the optimal position. CONCLUSION: Weight + 6 guide is not recommended to estimate ETT insertion length in extremely preterm infants. Gestation-based guide may be more appropriate to estimate ETT insertion length in this group of infants.


Subject(s)
Body Weight , Infant, Extremely Premature , Intubation, Intratracheal , Birth Weight , Humans , Infant, Newborn , Infant, Premature , Intubation, Intratracheal/adverse effects , Logistic Models , Medical Errors , Retrospective Studies , Tomography, X-Ray Computed , Trachea/diagnostic imaging
10.
Arch Dis Child Fetal Neonatal Ed ; 104(3): F298-F305, 2019 May.
Article in English | MEDLINE | ID: mdl-30049724

ABSTRACT

OBJECTIVE: To examine the feasibility of a trial allocating different blood pressure (BP) intervention levels for treatment in extremely preterm infants. DESIGN: Three-arm open randomised controlled trial performed between February 2013 and April 2015. SETTING: Single tertiary level neonatal intensive care unit. PATIENTS: Infants born <29 weeks' gestation were eligible to participate, if parents consented and they did not have a major congenital malformation. INTERVENTIONS: Infants were randomised to different levels of mean arterial BP at which they received cardiovascular support: active (<30 mm Hg), moderate (

Subject(s)
Blood Pressure/physiology , Cardiotonic Agents/therapeutic use , Hypotension/drug therapy , Infant, Premature, Diseases/drug therapy , Birth Weight , Blood Pressure Determination/methods , Brain/diagnostic imaging , Female , Gestational Age , Humans , Hypotension/diagnosis , Hypotension/physiopathology , Infant, Extremely Premature/physiology , Infant, Newborn , Infant, Premature, Diseases/diagnosis , Infant, Premature, Diseases/physiopathology , Intensive Care, Neonatal/methods , Male , Patient Selection , Pilot Projects , Ultrasonography
11.
Acta Paediatr ; 107(11): 1909-1916, 2018 11.
Article in English | MEDLINE | ID: mdl-29663524

ABSTRACT

AIM: To determine whether early echocardiographic ductal parameters identified infants who subsequently received medical or surgical treatment of the patent ductus arteriosus (PDA). METHODS: Infants <29 weeks had PDA size in 2D and colour, flow velocity and patterns obtained on days 1 and 3. Infants were followed up to identify those subsequently receiving treatment for symptomatic PDA by clinicians who were unaware of scan results. Receiver operator characteristics curves and logistic regression were performed. RESULTS: Sixty infants were studied. Mean (SD) gestation and birthweight were 25.8 (1.5) weeks and 817 (190) grams, respectively. Twenty-four (40%) infants received medical treatment, and nine (15%) infants received surgical ligation of PDA at a median age of 12 and 37 days, respectively. PDA size on days 1 and 3, change in ductal size between days 1 and 3, flow pattern/velocity did not predict whether infants subsequently received medical or surgical management of PDA. Using logistic regression, gestation (p = 0.006) was the only factor that predicted whether infants would subsequently receive medical or surgical treatment for PDA in this cohort. CONCLUSION: Echocardiographic ductal parameters on day 1 or 3 did not identify infants who received PDA treatment. Gestation was the most powerful predictor for receiving medical or surgical treatment of PDA.


Subject(s)
Ductus Arteriosus, Patent/diagnostic imaging , Cohort Studies , Ductus Arteriosus, Patent/therapy , Echocardiography , Humans , Infant, Extremely Premature , Infant, Newborn , Predictive Value of Tests
12.
Front Neurol ; 9: 87, 2018.
Article in English | MEDLINE | ID: mdl-29535674

ABSTRACT

BACKGROUND: Cerebral electrical activity in extremely preterm infants is affected by various factors including blood gas and circulatory parameters. OBJECTIVE: To investigate whether continuously measured invasive mean arterial blood pressure (BP) is associated with electroencephalographic (EEG) discontinuity in extremely preterm infants. STUDY DESIGN: This prospective observational study examined 51 newborn infants born <29 weeks gestation in the first 3 days after birth. A single channel of raw EEG was used to quantify discontinuity. Mean BP was acquired using continuous invasive measurement and Doppler ultrasound was used to measure left ventricular output (LVO) and common carotid artery blood flow (CCAF). RESULTS: Median gestation and birthweight were 25.6 weeks and 760 g, respectively. Mean discontinuity reduced significantly between days 1 and 3. EEG discontinuity was significantly related to gestation, pH and BP. LVO and CCAF were not associated with EEG discontinuity. CONCLUSION: Continuously measured invasive mean arterial BP was found to have a negative relationship with EEG discontinuity; increasing BP was associated with lower EEG discontinuity. This did not appear to be mediated by surrogates of systemic or cerebral blood flow. Infants receiving inotropic support had significantly increased EEG discontinuity on the first day after birth.

13.
BMJ Case Rep ; 20112011 Mar 03.
Article in English | MEDLINE | ID: mdl-22707620

ABSTRACT

A 5-year-old girl of Ghanaian origin presented to the accident and emergency department with genital bleeding of sudden onset in the previous 12 h. A diagnosis of urethral prolapse was made. The congestion and bleeding settled with a daily sitz bath and topical oestrogen cream for 4 weeks, while the prolapse was referred to urologists.


Subject(s)
Pelvic Organ Prolapse/diagnosis , Urethral Diseases/diagnosis , Child, Preschool , Female , Hemorrhage/etiology , Humans , Pelvic Organ Prolapse/complications , Urethral Diseases/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...