Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(11)2023 May 26.
Article in English | MEDLINE | ID: mdl-37299832

ABSTRACT

One of the main challenges in the development of a plasma diagnostic and control system for DEMO is the need to cope with unprecedented radiation levels in a tokamak during long operation periods. A list of diagnostics required for plasma control has been developed during the pre-conceptual design phase. Different approaches are proposed for the integration of these diagnostics in DEMO: in equatorial and upper ports, in the divertor cassette, on the inner and outer surfaces of the vacuum vessel and in diagnostic slim cassettes, a modular approach developed for diagnostics requiring access to the plasma from several poloidal positions. According to each integration approach, diagnostics will be exposed to different radiation levels, with a considerable impact on their design. This paper provides a broad overview of the radiation environment that diagnostics in DEMO are expected to face. Using the water-cooled lithium lead blanket configuration as a reference, neutronics simulations were performed for pre-conceptual designs of in-vessel, ex-vessel and equatorial port diagnostics representative of each integration approach. Flux and nuclear load calculations are provided for several sub-systems, along with estimations of radiation streaming to the ex-vessel for alternative design configurations. The results can be used as a reference by diagnostic designers.

2.
J Phys Condens Matter ; 33(28)2021 05 31.
Article in English | MEDLINE | ID: mdl-33906173

ABSTRACT

The experimental thermal neutron cross sections of the 20 proteinogenic amino acids have been measured over the incident-neutron energy range spanning from 1 meV to 10 keV and data have been interpreted using the multi-phonon expansion based on first-principles calculations. The scattering cross section, dominated by the incoherent inelastic contribution from the hydrogen atoms, can be rationalised in terms of the average contributions of different functional groups, thus neglecting their correlation. These results can be used for modelling the total neutron cross sections of complex organic systems like proteins, muscles, or human tissues from a limited number of starting input functions. This simplification is of crucial importance for fine-tuning of transport simulations used in medical applications, including boron neutron capture therapy as well as secondary neutrons-emission induced during proton therapy. Moreover, the parametrized neutron cross sections allow a better treatment of neutron scattering experiments, providing detailed sample self-attenuation corrections for a variety of biological and soft-matter systems.


Subject(s)
Amino Acids , Neutrons , Humans , Proton Therapy
3.
Materials (Basel) ; 14(3)2021 Jan 26.
Article in English | MEDLINE | ID: mdl-33530362

ABSTRACT

The use of wide-band-gap solid-state neutron detectors is expanding in environments where a compact size and high radiation hardness are needed, such as spallation neutron sources and next-generation fusion machines. Silicon carbide is a very promising material for use as a neutron detector in these fields because of its high resistance to radiation, fast response time, stability and good energy resolution. In this paper, measurements were performed with neutrons from the ISIS spallation source with two different silicon carbide detectors together with stability measurements performed in a laboratory under alpha-particle irradiation for one week. Some consideration to the impact of the casing of the detector on the detector's counting rate is given. In addition, the detector response to Deuterium-Deuterium (D-D) fusion neutrons is described by comparing neutron measurements at the Frascati Neutron Generator with a GEANT4 simulation. The good stability measurements and the assessment of the detector response function indicate that such a detector can be used as both a neutron counter and spectrometer for 2-4 MeV neutrons. Furthermore, the absence of polarization effects during neutron and alpha irradiation makes silicon carbide an interesting alternative to diamond detectors for fast neutron detection.

4.
Anal Bioanal Chem ; 409(26): 6133-6139, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28808737

ABSTRACT

Distribution, penetration depth and amount of new mineralogical phases formed after the interaction between an inorganic treatment and a matrix are key factors for the evaluation of the conservation treatment behaviour. Nowadays, the conventional analytical methodologies, such as vibrational spectroscopies, scanning electron microscopy and X-ray diffraction, provide only qualitative and spot information. Here, we report, for the first time, the proof of concept of a methodology based on neutron imaging able to achieve quantitative data useful to assess the formation of calcium oxalate in a porous carbonatic stone treated with ammonium oxalate. Starting from the neutron attenuation coefficient of Noto stone-treated specimens, the concentrations of newly formed calcium oxalate and the diffusion coefficient have been calculated for both sound and decayed substrates. These outcomes have been also used for a comparative study between different treatment modalities. Graphical abstract Horizontal slice at 300 mm depth and CaOx molar density profile by NEUTRA output.

SELECTION OF CITATIONS
SEARCH DETAIL
...