Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Opt Soc Am A Opt Image Sci Vis ; 41(6): 1140-1151, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38856428

ABSTRACT

Respiration rate (RR) holds significance as a human health indicator. Presently, the conventional RR monitoring system requires direct physical contact, which may cause discomfort and pain. Therefore, this paper proposes a non-contact RR monitoring system integrating RGB and thermal imaging through RGB-thermal image alignment. The proposed method employs an advanced image processing algorithm for automatic region of interest (ROI) selection. The experimental results demonstrated a close correlation and a lower error rate between measured thermal, measured RGB, and reference data. In summary, the proposed non-contact system emerges as a promising alternative to conventional contact-based approaches without the associated discomfort and pain.


Subject(s)
Respiratory Rate , Respiratory Rate/physiology , Humans , Algorithms , Image Processing, Computer-Assisted/methods , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Thermography/instrumentation , Thermography/methods , Color
2.
J Imaging ; 7(9)2021 Sep 17.
Article in English | MEDLINE | ID: mdl-34564114

ABSTRACT

Fast edge detection of images can be useful for many real-world applications. Edge detection is not an end application but often the first step of a computer vision application. Therefore, fast and simple edge detection techniques are important for efficient image processing. In this work, we propose a new edge detection algorithm using a combination of the wavelet transform, Shannon entropy and thresholding. The new algorithm is based on the concept that each Wavelet decomposition level has an assumed level of structure that enables the use of Shannon entropy as a measure of global image structure. The proposed algorithm is developed mathematically and compared to five popular edge detection algorithms. The results show that our solution is low redundancy, noise resilient, and well suited to real-time image processing applications.

3.
J Imaging ; 7(2)2021 Feb 05.
Article in English | MEDLINE | ID: mdl-34460627

ABSTRACT

The World Health Organization (WHO) has declared COVID-19 a pandemic. We review and reduce the clinical literature on diagnosis of COVID-19 through symptoms that might be remotely detected as of early May 2020. Vital signs associated with respiratory distress and fever, coughing, and visible infections have been reported. Fever screening by temperature monitoring is currently popular. However, improved noncontact detection is sought. Vital signs including heart rate and respiratory rate are affected by the condition. Cough, fatigue, and visible infections are also reported as common symptoms. There are non-contact methods for measuring vital signs remotely that have been shown to have acceptable accuracy, reliability, and practicality in some settings. Each has its pros and cons and may perform well in some challenges but be inadequate in others. Our review shows that visible spectrum and thermal spectrum cameras offer the best options for truly noncontact sensing of those studied to date, thermal cameras due to their potential to measure all likely symptoms on a single camera, especially temperature, and video cameras due to their availability, cost, adaptability, and compatibility. Substantial supply chain disruptions during the pandemic and the widespread nature of the problem means that cost-effectiveness and availability are important considerations.

4.
J Imaging ; 7(8)2021 Jul 23.
Article in English | MEDLINE | ID: mdl-34460758

ABSTRACT

Infants with fragile skin are patients who would benefit from non-contact vital sign monitoring due to the avoidance of potentially harmful adhesive electrodes and cables. Non-contact vital signs monitoring has been studied in clinical settings in recent decades. However, studies on infants in the Neonatal Intensive Care Unit (NICU) are still limited. Therefore, we conducted a single-center study to remotely monitor the heart rate (HR) and respiratory rate (RR) of seven infants in NICU using a digital camera. The region of interest (ROI) was automatically selected using a convolutional neural network and signal decomposition was used to minimize the noise artefacts. The experimental results have been validated with the reference data obtained from an ECG monitor. They showed a strong correlation using the Pearson correlation coefficients (PCC) of 0.9864 and 0.9453 for HR and RR, respectively, and a lower error rate with RMSE 2.23 beats/min and 2.69 breaths/min between measured data and reference data. A Bland-Altman analysis of the data also presented a close correlation between measured data and reference data for both HR and RR. Therefore, this technique may be applicable in clinical environments as an economical, non-contact, and easily deployable monitoring system, and it also represents a potential application in home health monitoring.

5.
Biomed Eng Online ; 16(1): 101, 2017 Aug 08.
Article in English | MEDLINE | ID: mdl-28789685

ABSTRACT

BACKGROUND: Remote physiological measurement might be very useful for biomedical diagnostics and monitoring. This study presents an efficient method for remotely measuring heart rate and respiratory rate from video captured by a hovering unmanned aerial vehicle (UVA). The proposed method estimates heart rate and respiratory rate based on the acquired signals obtained from video-photoplethysmography that are synchronous with cardiorespiratory activity. METHODS: Since the PPG signal is highly affected by the noise variations (illumination variations, subject's motions and camera movement), we have used advanced signal processing techniques, including complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and canonical correlation analysis (CCA) to remove noise under these assumptions. RESULTS: To evaluate the performance and effectiveness of the proposed method, a set of experiments were performed on 15 healthy volunteers in a front-facing position involving motion resulting from both the subject and the UAV under different scenarios and different lighting conditions. CONCLUSION: The experimental results demonstrated that the proposed system with and without the magnification process achieves robust and accurate readings and have significant correlations compared to a standard pulse oximeter and Piezo respiratory belt. Also, the squared correlation coefficient, root mean square error, and mean error rate yielded by the proposed method with and without the magnification process were significantly better than the state-of-the-art methodologies, including independent component analysis (ICA) and principal component analysis (PCA).


Subject(s)
Heart Rate , Monitoring, Physiologic/instrumentation , Remote Sensing Technology/instrumentation , Respiration , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Signal Processing, Computer-Assisted , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...