Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Antibiotics (Basel) ; 12(9)2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37760711

ABSTRACT

Chlorhexidine is the most commonly used anti-infective drug in dentistry. To treat infected void areas, a drug-loaded material that swells to fill the void and releases the drug slowly is needed. This study investigated the encapsulation and release of chlorhexidine from cellulose acetate nanofibers for use as an antibacterial treatment for dental bacterial infections by oral bacteria Streptococcus mutans and Enterococcus faecalis. This study used a commercial electrospinning machine to finely control the manufacture of thin, flexible, chlorhexidine-loaded cellulose acetate nanofiber mats with very-small-diameter fibers (measured using SEM). Water absorption was measured gravimetrically, drug release was analyzed by absorbance at 254 nm, and antibiotic effects were measured by halo analysis in agar. Slow electrospinning at lower voltage (14 kV), short target distance (14 cm), slow traverse and rotation, and syringe injection speeds with controlled humidity and temperature allowed for the manufacture of strong, thin films with evenly cross-meshed, uniform low-diameter nanofibers (640 nm) that were flexible and absorbed over 600% in water. Chlorhexidine was encapsulated efficiently and released in a controlled manner. All formulations killed both bacteria and may be used to fill infected voids by swelling for intimate contact with surfaces and hold the drug in the swollen matrix for effective bacterial killing in dental settings.

2.
Chest ; 158(4): 1713-1722, 2020 10.
Article in English | MEDLINE | ID: mdl-32561443

ABSTRACT

BACKGROUND: Air pollution and OSA are independently associated with systemic inflammation, but it is unknown if these exposures interact to influence systemic inflammation. RESEARCH QUESTION: The study objective was to determine the relative importance of these factors and their combined potential to influence systemic inflammation in patients under assessment for sleep ailments. STUDY DESIGN AND METHODS: A total of 315 patients contributed data, including a questionnaire, polysomnogram, and morning serum IL-6 and IL-10 concentrations. For each patient, residential annual average air pollution exposure (nitrogen dioxide [NO2], black carbon [BC], and particulate matter with an aerodynamic diameter ≤ 2.5 µm [PM2.5]) was estimated with a land use regression model. Linear regression modeling was used adjusting for age, sex, apnea-hypopnea index, BMI, smoking, socioeconomic status, and comorbidities. RESULTS: In adjusted models, quartile 4 PM2.5 exposure (compared with quartiles 1-3) was associated with increased IL-6 and IL-10 concentrations (estimated adjusted, 7.1 pg/mL [95% CI, 2.5-11.7; P < .01] and 71.4 pg/mL [95% CI, 38.2-103.7; P < .0001], respectively). OSA, BC, and NO2 were not associated with IL-6 or IL-10 in similar analyses; however, moderate to severe OSA influenced the effect of BC on IL-6 (interaction term, P = .01), with no significant interaction terms observed for NO2 or PM2.5. Subsequent stratified analysis showed that in the 173 patients with moderate to severe OSA, quartile 4 BC exposure (compared with quartiles 1-3) was associated with an increased IL-6 concentration (estimated adjusted, 8.9 pg/mL; 95% CI, 1.7-16.1; P = .02). INTERPRETATION: Long-term residential PM2.5 exposure was associated with increased IL-6 and IL-10 concentrations in patients evaluated for suspected OSA. BC exposure was also associated with increased IL-6 but only in the subgroup of patients with moderate to severe OSA. These data suggest the potential for joint effects of moderate to severe OSA and air pollution on systemic inflammation.


Subject(s)
Air Pollution/adverse effects , Inflammation/etiology , Sleep Apnea, Obstructive/complications , Aged , Cohort Studies , Female , Humans , Inflammation/blood , Interleukin-10/blood , Interleukin-6/blood , Male , Middle Aged , Sleep Apnea, Obstructive/blood , Urban Health
3.
J Appl Oral Sci ; 27: e20180663, 2019.
Article in English | MEDLINE | ID: mdl-31596368

ABSTRACT

OBJECTIVE: To investigate the use of polymethyl methacrylate (PMMA) electrospun fiber mats containing different amounts of polyethylene oxide (PEO) as a doxycycline delivery system and to test antibacterial activity against an oral pathogen. METHODOLOGY: PMMA powders or PEO (mol wt 200 Kd) (10,20,30% w/w/) were dissolved in N, N-dimethylformamide (DMF) to obtain a final polymer concentration of 15% in DMF (w/v). 2% Doxycycline monohydrate was added to the solutions and submitted to vortex mixing. The solution was transferred to a plastic syringe and fit into a nanofiber electrospinning unit. The parameters applied were: voltage at 17.2 kV; distance of 20 cm between the needle tip and the collector plate; target speed at 2 m/min; and transverse speed at 1cm/min. Syringe pump speed was 0.15 mm/min. The drug release analysis was performed by removing aliquots of the drug-containing solution (in PBS) at specific periods. Doxycycline release was quantified using RP-HPLC. Fiber mats from all groups had their antibacterial action tested against S. mutans based on inhibition halos formed around the specimens. The experiments were performed in triplicate. Gravimetric analysis at specific periods was performed to determine any polymer loss. Morphological characterization of the electrospun fibers was completed under an optical microscope followed by SEM analysis. RESULTS: The addition of PEO to the PMMA fibers did not affect the appearance and diameter of fibers. However, increasing the %PEO caused higher doxycycline release in the first 24 h. Fibers containing 30% PEO showed statistically significant higher release when compared with the other groups. Doxycycline released from the fibers containing 20% or 30% of PEO showed effective against S. mutans. CONCLUSION: The incorporation of PEO at 20% and 30% into PMMA fiber mat resulted in effective drug release systems, with detected antibacterial activity against S. mutans.


Subject(s)
Anti-Bacterial Agents/pharmacokinetics , Doxycycline/pharmacokinetics , Nanofibers/chemistry , Polyethylene Glycols/pharmacokinetics , Polymethyl Methacrylate/pharmacokinetics , Analysis of Variance , Anti-Bacterial Agents/chemistry , Chromatography, High Pressure Liquid/methods , Doxycycline/chemistry , Immersion , Microscopy, Electron, Scanning , Molecular Weight , Polyethylene Glycols/chemistry , Polymethyl Methacrylate/chemistry , Reproducibility of Results , Streptococcus mutans/drug effects , Time Factors , Water/chemistry
4.
J Oral Biosci ; 61(1): 37-42, 2019 03.
Article in English | MEDLINE | ID: mdl-30929800

ABSTRACT

OBJECTIVES: Nanocrystalline cellulose (NCC) is a sustainable material with excellent mechanical properties and can potentially be used as a reinforcement agent. The objective of this work was to test the effects of NCC incorporation on the mechanical properties of electrospun polyacrylonitrile (PAN) nanofibers. METHODS: Eleven percent in weight of PAN (molecular weight 150 kD) in a dimethylformamide (DMF) solution was electrospun at 14.6 kV. Nonfunctionalized NCC was added to the solution at 1%, 2%, or 3 wt% (NCC/PAN). Suspensions were mixed and sonicated for 2 h before spinning. Strips (5 × 0.5 cm) were cut from the spun mat, parallel and perpendicular to the rotational direction of the fiber collection drum. Tensile tests were performed, and ultimate tensile strength (UTS), yield strength (YS; 0.3%), elastic modulus (E), and elongation at maximum stress (EMS, %) were calculated from stress-strain plots. Data were analyzed by multiple t tests and one-way ANOVA (α = 0.05). RESULTS: Among all groups, samples with 3 wt % NCC loading had significantly superior mechanical properties. The fiber mats showed anisotropic behavior. CONCLUSIONS: Regardless of concentration, the addition of NCC resulted in increased UTS, E, and YS of the nanofibers.


Subject(s)
Nanofibers , Acrylic Resins , Cellulose , Tensile Strength
5.
J. appl. oral sci ; 27: e20180663, 2019. tab, graf
Article in English | LILACS, BBO - Dentistry | ID: biblio-1040224

ABSTRACT

Abstract Objective: To investigate the use of polymethyl methacrylate (PMMA) electrospun fiber mats containing different amounts of polyethylene oxide (PEO) as a doxycycline delivery system and to test antibacterial activity against an oral pathogen. Methodology: PMMA powders or PEO (mol wt 200 Kd) (10,20,30% w/w/) were dissolved in N, N-dimethylformamide (DMF) to obtain a final polymer concentration of 15% in DMF (w/v). 2% Doxycycline monohydrate was added to the solutions and submitted to vortex mixing. The solution was transferred to a plastic syringe and fit into a nanofiber electrospinning unit. The parameters applied were: voltage at 17.2 kV; distance of 20 cm between the needle tip and the collector plate; target speed at 2 m/min; and transverse speed at 1cm/min. Syringe pump speed was 0.15 mm/min. The drug release analysis was performed by removing aliquots of the drug-containing solution (in PBS) at specific periods. Doxycycline release was quantified using RP-HPLC. Fiber mats from all groups had their antibacterial action tested against S. mutans based on inhibition halos formed around the specimens. The experiments were performed in triplicate. Gravimetric analysis at specific periods was performed to determine any polymer loss. Morphological characterization of the electrospun fibers was completed under an optical microscope followed by SEM analysis. Results: The addition of PEO to the PMMA fibers did not affect the appearance and diameter of fibers. However, increasing the %PEO caused higher doxycycline release in the first 24 h. Fibers containing 30% PEO showed statistically significant higher release when compared with the other groups. Doxycycline released from the fibers containing 20% or 30% of PEO showed effective against S. mutans. Conclusion: The incorporation of PEO at 20% and 30% into PMMA fiber mat resulted in effective drug release systems, with detected antibacterial activity against S. mutans.


Subject(s)
Polyethylene Glycols/pharmacokinetics , Doxycycline/pharmacokinetics , Polymethyl Methacrylate/pharmacokinetics , Nanofibers/chemistry , Anti-Bacterial Agents/pharmacokinetics , Polyethylene Glycols/chemistry , Streptococcus mutans/drug effects , Time Factors , Water/chemistry , Microscopy, Electron, Scanning , Reproducibility of Results , Analysis of Variance , Chromatography, High Pressure Liquid/methods , Doxycycline/chemistry , Polymethyl Methacrylate/chemistry , Immersion , Anti-Bacterial Agents/chemistry , Molecular Weight
6.
Gen Dent ; 62(3): e7-e11, 2014.
Article in English | MEDLINE | ID: mdl-24784526

ABSTRACT

This in vitro study sought to evaluate how surface conditioning from bracket and mechanical cycling aging affected the bond strength between metallic brackets and bovine enamel, and to determine the adhesive remnant index. Eighty bovine incisors were embedded in acrylic resin using polyvinyl chloride rings and divided into 4 groups based on surface treatment (n = 20). Group 1 (control) received no surface treatment, Group 2 specimens were sandblasted with aluminum oxide particles, Group 3 specimens were sandblasted with silicon oxide and treated with a tribochemichemical silica coupling agent, and Group 4 specimens were primed with a multidomain protein-based agent. Half of the specimens were submitted to shear bond testing, while the others were subjected to mechanical cycling. ANOVA showed that mechanical cycling did not have a significant influence on bond strength (P = 0.9244), while surface conditioning of the brackets did (P = 0.0001). Tukey's test results were similar for mechanical cycling, and indicated that only Group 3 significantly improved the resin bond to the brackets; however, this group also demonstrated the highest percentage of enamel failure.


Subject(s)
Dental Cements/therapeutic use , Dental Enamel , Dental Etching/methods , Orthodontic Brackets , Animals , Cattle , Dental Bonding/methods , Dental Stress Analysis/methods , Incisor , Stress, Mechanical
7.
J Appl Oral Sci ; 21(5): 468-74, 2013.
Article in English | MEDLINE | ID: mdl-24212994

ABSTRACT

OBJECTIVE: This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. MATERIAL AND METHODS: Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). CONCLUSION: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.


Subject(s)
Dental Instruments , Image Processing, Computer-Assisted/methods , Root Canal Preparation/instrumentation , Software , Cone-Beam Computed Tomography , Equipment Design , Humans , Models, Anatomic , Reference Values , Reproducibility of Results , Rotation , Statistics, Nonparametric , Time Factors
8.
J. appl. oral sci ; 21(5): 468-474, Sep-Oct/2013. tab, graf
Article in English | LILACS, BBO - Dentistry | ID: lil-690086

ABSTRACT

OBJECTIVE: This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. MATERIAL AND METHODS: Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). CONCLUSION: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop. .


Subject(s)
Humans , Dental Instruments , Image Processing, Computer-Assisted/methods , Root Canal Preparation/instrumentation , Software , Cone-Beam Computed Tomography , Equipment Design , Models, Anatomic , Reference Values , Reproducibility of Results , Rotation , Statistics, Nonparametric , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...