Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Soc Mass Spectrom ; 24(6): 828-34, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23568027

ABSTRACT

The method of phasing broadband Fourier transform ion cyclotron resonance (FT-ICR) spectra allows plotting the spectra in the absorption-mode; this new approach significantly improves the quality of the data at no extra cost. Herein, an internal calibration method for calculating the phase function has been developed and successfully applied to the top-down spectra of modified proteins, where the peak intensities vary by 100×. The result shows that the use of absorption-mode spectra allows more peaks to be discerned within the recorded data, and this can reveal much greater information about the protein and modifications under investigation. In addition, noise and harmonic peaks can be assigned immediately in the absorption-mode.


Subject(s)
Fourier Analysis , Mass Spectrometry/methods , Proteins/chemistry , Absorption , Acoustics , Artifacts , Peptides/chemistry , Signal-To-Noise Ratio
2.
Anal Chem ; 84(20): 8579-86, 2012 Oct 16.
Article in English | MEDLINE | ID: mdl-23003319

ABSTRACT

Two polymeric excipients, typically used in enabling drug delivery approaches, are Gelucire 44/14 (a product of Gattefosse s.a, St Priest, France) and polysorbate 80; these are known to improve solubility of poorly water-soluble drugs and, hence, increase their effective bioavailability. In addition to the use of Gelucire 44/14 and polysorbate 80 as excipients in drugs, they are also widely used as cosmetic and food additives. In general, complex structures and compositions of drug excipients impact performance of the formulation in vivo and consequently affect drug absorption. Therefore, a comparison between excipients from different suppliers and batches to batch would provide an indication of the impact on drug product performance and also the study of the effectiveness of the system and any problems associated with the formulation. In this study, high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) is used to compare two different batches of Gelucire 44/14 and polysorbate 80. With the high resolving power of FTICR MS, it was possible to differentiate between batches of excipients from differences in the identified components. The improved resolution offered by FTICR MS allowed assignment of four polymeric series differences in the two batches of polysorbate 80 and the presence of one compound and three polymeric series differences in the two batches of Gelucire 44/14. The increase in the number of components assigned in the excipients batch using FTICR-MS, compared to the numbers previously assigned by lower resolution TOF MS, underlines the importance of high resolution techniques in analysis of highly complex mixtures.


Subject(s)
Drug Carriers/chemistry , Excipients/chemistry , Mass Spectrometry , Polyethylene Glycols/chemistry , Polysorbates/chemistry , Fourier Analysis , Mass Spectrometry/methods
3.
Anal Chem ; 83(22): 8477-83, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-21975143

ABSTRACT

It has been known for almost 40 years that phase correction of Fourier transform ion cyclotron resonance (FTICR) data can generate an absorption-mode spectrum with much improved peak shape compared to the conventional magnitude-mode. However, research on phasing has been slow due to the complexity of the phase-wrapping problem. Recently, the method for phasing a broadband FTICR spectrum has been solved in the MS community which will surely resurrect this old topic. This paper provides a discussion on the data processing procedure of phase correction and features of the phase function based on both a mathematical treatment and experimental data. Finally, it is shown that the same phase function can be optimized by adding correction factors and can be applied from one experiment to another with different instrument parameters, regardless of the sample measured. Thus, in the vast majority of cases, the phase function needs to be calculated just once, whenever the instrument is calibrated.


Subject(s)
Fourier Analysis , Mass Spectrometry/methods , Petroleum/analysis , Calibration , Cyclotrons
4.
Environ Toxicol Chem ; 28(12): 2685-94, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19663538

ABSTRACT

Researchers recognize that ionization state may influence the biological activity of weak acids and bases. Dissociation in aqueous solutions is controlled by the pKa of a compound and the pH of the matrix. Because many pharmaceuticals are implicitly designed as ionizable compounds, site-specific variability in pH of receiving waters may introduce uncertainty to ecological risk assessments. The present study employed 48-h and 7-d toxicity tests with Pimephales promelas exposed to the model weak base pharmaceutical sertraline over a gradient of environmentally relevant surface water pHs. The 48-h experiments were completed in triplicate, and the average lethal concentration values were 647, 205, and 72 microL sertraline at pH 6.5, 7.5, and 8.5, respectively. Survivorship, growth, and feeding rate (a nontraditional endpoint linked by other researchers to sertraline's specific mode of action) were monitored during the 7-d experiment. Adverse effects were more pronounced when individuals were exposed to sertraline at pH 8.5 compared to pH 7.5 and 6.5. The pH-dependent toxicological relationships from these studies were related to in-stream pH data for two streams in the Brazos River basin of central Texas, USA. This predictive approach was taken because of the scarcity of environmental analytical data for sertraline. The results of this study emphasized temporal variability associated with in-stream pH linked to seasonal differences within and between these spatially related systems. Relating site-specific pH variability of surface waters to ionization state may allow researchers to reduce uncertainty during ecological risk assessment of pharmaceuticals by improving estimates of biological effects associated with exposure.


Subject(s)
Selective Serotonin Reuptake Inhibitors/toxicity , Sertraline/toxicity , Water Pollutants, Chemical/toxicity , Animals , Cyprinidae , Dose-Response Relationship, Drug , Hydrogen-Ion Concentration , Toxicity Tests, Acute
5.
Environ Toxicol Chem ; 28(12): 2587-97, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19320536

ABSTRACT

Pharmaceuticals and personal care products are being increasingly reported in a variety of biological matrices, including fish tissue; however, screening studies have presently not encompassed broad geographical areas. A national pilot study was initiated in the United States to assess the accumulation of pharmaceuticals and personal care products in fish sampled from five effluent-dominated rivers that receive direct discharge from wastewater treatment facilities in Chicago, Illinois; Dallas, Texas; Orlando, Florida; Phoenix, Arizona; and West Chester, Pennsylvania, USA. Fish were also collected from the Gila River, New Mexico, USA, as a reference condition expected to be minimally impacted by anthropogenic influence. High performance liquid chromatography-tandem mass spectrometry analysis of pharmaceuticals revealed the presence of norfluoxetine, sertraline, diphenhydramine, diltiazem, and carbamazepine at nanogram-per-gram concentrations in fillet composites from effluent-dominated sampling locations; the additional presence of fluoxetine and gemfibrozil was confirmed in liver tissue. Sertraline was detected at concentrations as high as 19 and 545 ng/g in fillet and liver tissue, respectively. Gas chromatography-tandem mass spectrometry analysis of personal care products in fillet composites revealed the presence of galaxolide and tonalide at maximum concentrations of 2,100 and 290 ng/g, respectively, and trace levels of triclosan. In general, more pharmaceuticals were detected at higher concentrations and with greater frequency in liver than in fillet tissues. Higher lipid content in liver tissue could not account for this discrepancy as no significant positive correlations were found between accumulated pharmaceutical concentrations and lipid content for either tissue type from any sampling site. In contrast, accumulation of the personal care products galaxolide and tonalide was significantly related to lipid content. Results suggest that the detection of pharmaceuticals and personal care products was dependent on the degree of wastewater treatment employed.


Subject(s)
Cosmetics/metabolism , Fishes/metabolism , Pharmaceutical Preparations/metabolism , Water Pollutants, Chemical/metabolism , Animals , Chromatography, High Pressure Liquid , Cosmetics/analysis , Pharmaceutical Preparations/analysis , Pilot Projects , Quality Control , Regression Analysis , Tandem Mass Spectrometry , Waste Disposal, Fluid
SELECTION OF CITATIONS
SEARCH DETAIL
...