Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 28(Pt 3): 977-986, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33950006

ABSTRACT

We report on the development of a high-resolution and highly efficient beamline for soft X-ray resonant inelastic X-ray scattering (RIXS) located at the Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations, as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angles over a wide range. Several high-precision instruments developed in-house for this beamline are described briefly. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power of 4.2 × 104, while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impact of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, i.e. La2-xSrxCuO4. The measurements reveal the A1g buckling phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge-density waves.

2.
J Synchrotron Radiat ; 10(Pt 6): 450-4, 2003 Nov 01.
Article in English | MEDLINE | ID: mdl-14551446

ABSTRACT

A novel monolithic mechanical bender has been designed and fabricated to meet the requirements of an active polynomial grating in a new soft X-ray scattering and emission beamline at the National Synchrotron Radiation Research Center, Taiwan. This compact bender achieves nearly fixed center point under different bending conditions. Moreover, the compact bender can be bent to a desirable third-order polynomial surface profile to cancel the defocus and coma aberrations using two PZT actuators. Theoretical analysis reveals that the grating has unprecedented spectral resolving power. A detailed mechanical analysis has been conducted and a prototype bender was fabricated and tested. The results indicate that the performance of the bender is excellent and is therefore suitable to be used in the active grating.


Subject(s)
Equipment Failure Analysis , Optics and Photonics/instrumentation , Scattering, Radiation , Synchrotrons/instrumentation , X-Ray Diffraction/instrumentation , X-Ray Diffraction/methods , Computer-Aided Design , Elasticity , Equipment Design , Feedback , Motion , Physical Stimulation/instrumentation , Stress, Mechanical , Transducers
3.
J Synchrotron Radiat ; 5(Pt 3): 801-3, 1998 May 01.
Article in English | MEDLINE | ID: mdl-15263658

ABSTRACT

A compact mirror manipulator which has high stiffness and is easily adjustable has been developed for new beamlines at SRRC. It consists of a vertical stem to support the mirror and allows for six-axis precise positioning. The rotation adjustment is designed with a minimum of cross-coupling between adjustments. An independent support is fixed to the ground to reduce vibration from the chamber and the pump. Some performance test results in vacuum and in atmosphere, including vibration, repeatability, long-term drift etc., are described in this paper.

SELECTION OF CITATIONS