Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chem Lab Med ; 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38641868

ABSTRACT

OBJECTIVES: Trace elements (TEs) are ubiquitous. TE concentrations vary among individuals and countries, depending on factors such as living area, workplaces and diet. Deficit or excessive TEs concentrations have consequences on the proper functioning of human organism so their biomonitoring is important. The aim of this project was to provide reference values for TEs concentrations in the Swiss population. METHODS: The 1,078 participants to the SKiPOGH cohort included in this study were aged 18-90 years. Their 24-h urine and/or plasma samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) to determine 24 TEs concentrations: Ag, Al, As, Be, Bi, Cd, Co, Cr, Cu, Hg, I, Li, Mn, Mo, Ni, Pb, Pd, Pt, Sb, Se, Sn, Tl, V and Zn. Statistical tests were performed to evaluate the influence of covariates (sex, age, BMI, smoking) on these results. Reference intervals for the Swiss adult population were also defined. RESULTS: TEs concentrations were obtained for respectively 994 and 903 persons in plasma and urine matrices. It was possible to define percentiles of interest (P50 and P95) for almost all the TEs. Differences in TEs distribution between men and women were noticed in both matrices; age was also a cofactor. CONCLUSIONS: This first Swiss biomonitoring of a large TEs-panel offers reference values in plasma and in urine for the Swiss population. The results obtained in this study were generally in line with clinical recommendations and comparable to levels reported in other population-based surveys.

2.
Clin Nutr ; 42(6): 972-986, 2023 06.
Article in English | MEDLINE | ID: mdl-37130500

ABSTRACT

INTRODUCTION: Some micronutrients have key roles in immune defence, including mucosal defence mechanisms and immunoglobulin production. Altered micronutrient status has been linked with COVID-19 infection and disease severity. We assessed the associations of selected circulating micronutrients with anti-SARS-CoV-2 IgG and IgA seropositivity in the Swiss community using early pandemic data. METHODS: Case-control study comparing the first PCR-confirmed COVID-19 symptomatic cases in the Vaud Canton (May to June 2020, n = 199) and controls (random population sample, n = 447), seronegative for IgG and IgA. The replication analysis included seropositive (n = 134) and seronegative (n = 152) close contacts from confirmed COVID-19 cases. Anti-SARS-CoV-2 IgG and IgA levels against the native trimeric spike protein were measured using the Luminex immunoassay. We measured plasma Zn, Se and Cu concentrations by ICP-MS, and 25-hydroxy-vitamin D3 (25(OH)D3) with LC-MS/MS and explored associations using multiple logistic regression. RESULTS: The 932 participants (54.1% women) were aged 48.6 ± 20.2 years (±SD), BMI 25.0 ± 4.7 kg/m2 with median C-Reactive Protein 1 mg/l. In logistic regressions, log2(Zn) plasma levels were negatively associated with IgG seropositivity (OR [95% CI]: 0.196 [0.0831; 0.465], P < 0.001; replication analyses: 0.294 [0.0893; 0.968], P < 0.05). Results were similar for IgA. We found no association of Cu, Se, and 25(OH)D3 with anti-SARS-CoV-2 IgG or IgA seropositivity. CONCLUSION: Low plasma Zn levels were associated with higher anti-SARS-CoV-2 IgG and IgA seropositivity in a Swiss population when the initial viral variant was circulating, and no vaccination available. These results suggest that adequate Zn status may play an important role in protecting the general population against SARS-CoV-2 infection. REGISTRY: CORONA IMMUNITAS:: ISRCTN18181860.


Subject(s)
COVID-19 , Humans , Female , Male , Case-Control Studies , Chromatography, Liquid , COVID-19/epidemiology , SARS-CoV-2 , Tandem Mass Spectrometry , Antibodies, Viral , Immunoglobulin G , Micronutrients , Zinc , Immunoglobulin A
3.
J Anal Toxicol ; 47(2): 175-181, 2023 Mar 21.
Article in English | MEDLINE | ID: mdl-35932154

ABSTRACT

Microsampling techniques became more popular in the last decades, and their use for common analyses such as trace element quantification by inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. We decided to compare two of these techniques (dried blood spots and microtubes) to evaluate their potential for the analysis of 12 trace elements in human whole blood: aluminum (Al), total arsenic (As), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), manganese (Mn), molybdenum (Mo), nickel (Ni), lead (Pb), selenium (Se) and zinc (Zn). Signal contributions from blank filter paper and instability at room temperature for several elements in the dried blood spot samples restrained our enthusiasm for the use of this technique. Conversely, microtube samples presented low background contamination and good stability under different temperature conditions. Therefore, our results demonstrate that the use of microtubes is more suitable than dried blood spots for trace element quantification in human blood, both in research and routine analysis.


Subject(s)
Selenium , Trace Elements , Humans , Spectrum Analysis , Selenium/analysis , Copper/analysis , Zinc
SELECTION OF CITATIONS
SEARCH DETAIL
...