Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Invasive Cardiol ; 31(12): E396, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31786535

ABSTRACT

OCT in a 74-year-old woman highlights how an angiographic coronary fenestration can be acquired through calcific nodule atherosclerosis in the coronary arteries. We demonstrate how tandem anatomic and physiologic assessment can be used to diagnose, functionally evaluate, and effectively treat this rare finding.


Subject(s)
Coronary Angiography/methods , Coronary Vessel Anomalies , Coronary Vessels , Percutaneous Coronary Intervention , Tomography, Optical Coherence/methods , Vascular Calcification , Aged , Coronary Artery Disease/diagnosis , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Coronary Vessels/surgery , Female , Humans , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Stents , Vascular Calcification/diagnosis , Vascular Calcification/surgery
2.
Oper Neurosurg (Hagerstown) ; 14(4): 351-358, 2018 04 01.
Article in English | MEDLINE | ID: mdl-28521024

ABSTRACT

BACKGROUND: Pericallosal artery aneurysm treatment may be challenging using traditional endovascular techniques. OBJECTIVE: To demonstrate the feasibility, efficacy, and safety of endovascular treatment of pericallosal artery aneurysm using flow diverters. METHODS: We performed a retrospective review of our institutional database from July 2013 through July 2016 and identified 7 subjects with a pericallosal artery aneurysm treated with the Pipeline embolization device (ev3 Neurovascular, Medtronic, Dublin, Ireland) and at least 1 follow-up angiogram. Technical feasibility, procedural complication, angiographic results, and clinical outcome were evaluated. RESULTS: Placement of the Pipeline embolization device was successful in all cases without evidence of procedural complication. Five out of 7 subjects showed a complete aneurysm occlusion at 6- to 12-mo follow-up angiogram. The 2 subjects with persistent aneurysm filling showed decreased aneurysm sac volume on follow-up angiograms (96% and 60%). There was no evidence of in-implant stenosis or intimal hyperplasia. No thromboembolic or hemorrhagic complications were seen during the follow-up period. Only 1 patient had a transient change in Modified Rankin scale score from baseline as a result of different unrelated procedure. CONCLUSION: Our preliminary results demonstrate feasibility of the use of flow diverter stent for treatment of aneurysms of the pericallosal artery with rate of aneurysm occlusion comparable to literature and without evidence of increased procedural or short-term morbidity. A long-term and larger cohort study is needed to validate our findings.


Subject(s)
Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Stents , Aged , Cerebral Angiography , Corpus Callosum/blood supply , Equipment Design , Female , Humans , Imaging, Three-Dimensional , Intracranial Aneurysm/diagnostic imaging , Male , Middle Aged , Retrospective Studies
3.
J Neurointerv Surg ; 9(6): 541-546, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27286991

ABSTRACT

OBJECTIVE: To evaluate the safety and efficacy of the 'Baby Trevo' (Trevo XP ProVue 3×20 mm Retriever) stent retriever for large vessel occlusions (LVOs) in acute ischemic stroke (AIS). MATERIALS AND METHODS: We retrospectively analyzed our stroke database and included all patients treated with the Baby Trevo for distal LVOs in AIS. Patient gender, mean age, vascular risk factors, National Institutes of Health Stroke Scale (NIHSS) score at presentation, and modified Rankin Scale (mRS) score at baseline and 90-day follow-up were documented. Reperfusion rates for the vessels treated were recorded using the Thrombolysis in Cerebral Infarction (TICI) classification. Occurrence of vasospasm and new or evolving infarcts in the treated vascular territory was documented. RESULTS: Thirty-five subjects with a mean NIHSS score of 18 were included. The Baby Trevo device was used in 38 branches of the anterior and posterior circulations. TICI 2b/3 blood flow was restored after one single pass in 20/38 (52.6%) and after two or three passes in 11 vessels. The remaining vessels required either more than three passes, showed less than a TICI 2b/3 reperfusion (n=3), or demonstrated failure to retrieve the clot (n=4). TICI 2b/3 reperfusion was achieved in 30 patients (85.7%). No vessel injuries, rupture, or significant vasospasm were seen. Overall, a mRS score of ≤2 was seen in 56.5% of the subjects successfully treated with the Baby Trevo at 90 days and in 81.3% of surviving patients; seven patients died (20%). CONCLUSIONS: Our preliminary data suggest that the 'Baby Trevo' achieves a high recanalization rate without any significant risk. Larger cohort studies are needed to validate the clinical benefit.


Subject(s)
Brain Ischemia/diagnostic imaging , Brain Ischemia/surgery , Stents/adverse effects , Stroke/diagnostic imaging , Stroke/surgery , Thrombectomy/methods , Adult , Aged , Aged, 80 and over , Cerebrovascular Circulation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Reperfusion/adverse effects , Retrospective Studies , Risk Factors , Thrombectomy/instrumentation , Time Factors , Treatment Outcome
4.
Interv Neuroradiol ; 23(2): 129-136, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27956518

ABSTRACT

Background Flow diverter (FD) malapposition is associated with stroke-related complications. We document the use of self-expanding nitinol stents to remove/reduce the ledge of a FD deployed for aneurysm treatment. Methods We identified five patients who were treated with the Pipeline embolization device (PED) in conjunction with a Neuroform EZ stent for inadequate wall apposition of the ends of the FD at our institution between May 2014 and July 2015. Among other parameters, angiographic results, cone-beam computed tomography assessment of wall apposition and patient clinical outcome were evaluated. Results Incomplete device end apposition was seen in three cases, and precarious positioning of the distal end of the PED over the aneurysm neck was seen in two cases. In all five cases, successful treatment with good wall apposition and proper pinning of the PED distal edge was achieved using an additional Neuroform EZ stent. Appropriate aneurysm neck coverage and flow stagnation was seen in all cases. The combination of high radial outward force and open-cell design permits the Neuroform EZ stent to jail the malappositioned edges of the FD while maintaining good vessel-wall apposition itself and prevent migration of the PED. Short-term follow-up angiography showed device patency and complete aneurysm obliteration in all cases. Conclusions Preliminary results of this small case series suggest that the Neuroform EZ stent allows for effective treatment of FD malapposition in selected patients amenable for this endovascular approach. Long-term and larger cohort studies are needed to validate these results.


Subject(s)
Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/therapy , Stents , Adult , Aged , Alloys , Angiography, Digital Subtraction , Cerebral Angiography , Cone-Beam Computed Tomography , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
5.
Cureus ; 8(5): e617, 2016 May 21.
Article in English | MEDLINE | ID: mdl-27382525

ABSTRACT

The endovascular management of acute ischemic stroke (AIS) due to emergency large vessel occlusion (ELVO) has become the standard of care after the recent publication of landmark randomized, controlled trials. Mechanical thrombectomy, in addition to intravenous thrombolysis (within 4.5 hours when eligible), is now part of the algorithm of the standard of care when treating AIS in patients with ELVO in the anterior circulation up to six hours after symptom onset. A newly introduced device, the Arc™ intracranial support catheter (Medtronic, Irvine, USA), is specifically designed for the introduction of neurointerventional devices into the cerebral vasculature and facilitates the delivery of microcatheters into smaller, more distal intracranial vessels. This technical report describes the use of the Arc™ intracranial support catheter in the setting of AIS.

6.
Interv Neuroradiol ; 22(3): 325-32, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26908591

ABSTRACT

BACKGROUND: A new generation of highly navigable large-bore aspiration catheters and retriever devices for intracranial mechanical thrombectomy has markedly improved recanalization rates, time and clinical outcomes. We report collected clinical data utilizing a new technique based on combined large lumen aspiration catheter and partially resheathed stent retriever (ARTS: Aspiration (catheter)-(stent) Retriever Technique for Stroke). This technique is applied, especially in presence of bulky/rubbery emboli, when resistance is felt while retracting the stent retriever; at that point the entire assembly is locked and removed in-toto under continuous aspiration with additional flow arrest. METHODS: A retrospective data analysis was performed to identify patients with large cerebral artery acute ischemic stroke treated with ARTS. The study was conducted between August 2013 and February 2015 at a single high volume stroke center. Procedural and clinical data were captured for analysis. RESULTS: Forty-two patients (median age 66 years) met inclusion criteria for this study. The ARTS was successful in achieving Thrombolysis in Cerebral Infarction (TICI) ≥2b revascularization in 97.6% of cases (TICI 2b = 18 patients, TICI 3 = 23 patients). Patients' median National Institutes of Health Stroke Scale score at admission was 18 (6-40). A 3-month follow-up modified Rankin Scale value of 0-2 was achieved in 65.7% of the successfully treated patients (average 2.4). Two patients (4.8%) developed symptomatic intraparenchymal hemorrhages. Six procedure unrelated deaths were observed. CONCLUSIONS: We found that ARTS is a fast, safe and effective method for endovascular recanalization of large vessel occlusions presenting within the context of acute ischemic stroke.


Subject(s)
Brain Ischemia/surgery , Catheters , Intracranial Thrombosis/surgery , Mechanical Thrombolysis/instrumentation , Stroke/surgery , Aged , Brain Ischemia/diagnostic imaging , Computed Tomography Angiography , Equipment Design , Female , Humans , Intracranial Thrombosis/diagnostic imaging , Magnetic Resonance Imaging , Male , Patient Selection , Retrospective Studies , Stroke/diagnostic imaging , Suction , Treatment Outcome
7.
Neuroradiology ; 58(3): 267-75, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26700827

ABSTRACT

INTRODUCTION: Flow diversion is being increasingly used to treat cerebral aneurysms. We present our experience using these stents to treat aneurysms distal to the circle of Willis with parent arteries smaller than 2.5 mm. METHODS: Aneurysms treated with a Pipeline Embolization Device in vessels less than 2.5 mm between June 2012 and August 2014 were included. We evaluated risk factors, family history of aneurysms, aneurysm characteristics, National Institute of Health Stroke Scale (NIHSS), and modified Rankin scale (mRS) on admission and angiography and clinical outcome at discharge, 6 months, and 1 year. RESULTS: We included seven patients with a mean age of 65 years. The parent vessel size ranged from 1.5 to 2.3 mm; mean 1.9 mm. Location of the aneurysms was as follows: two aneurysms centered along the pericallosal artery (one left, one right), one on the right angular artery, one aneurysm at the anterior communicating artery (ACom), one at the ACom-right A2 anterior cerebral artery (ACA), one at the lenticulostriate artery, and one at the A1-A2 ACA artery. Aneurysms ranged from 1 to 12 mm in diameter. All aneurysms were treated with a single Pipeline Embolization Device (PED). No peri- or post-procedural complications or mortality occurred. The patients were discharged with no change in NIHSS or mRS score. Angiographic follow-up was available in six patients. Angiography showed complete aneurysm occlusion in all. NIHSS and mRS remained unchanged at follow-up. CONCLUSION: Our preliminary results show that flow diversion technology is an effective and safe therapy for aneurysms located on small cerebral arteries. Larger studies with long-term follow-up are needed to validate our promising results.


Subject(s)
Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Stents , Aged , Embolization, Therapeutic/methods , Equipment Failure Analysis , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Prosthesis Design , Treatment Outcome
8.
J Neurointerv Surg ; 8(5): 501-6, 2016 May.
Article in English | MEDLINE | ID: mdl-25838199

ABSTRACT

BACKGROUND: Dissecting aneurysms located along the distal segments of the posterior inferior cerebellar artery (PICA) are extremely rare, accounting for only 0.5-0.7% of all intracranial aneurysms. Treatment of these aneurysms is challenging, both surgically and endovascularly. We present our preliminary experience and clinical data utilizing Onyx as an embolization agent in the treatment of these lesions with proximal parent artery preservation. METHODS: 7 consecutive ruptured peripheral PICA aneurysms, in 7 patients, were treated with superselective Onyx embolization at our institutions. According to the anatomical classification of Lister et al, these aneurysms were located in the lateral medullary segment (n=1), tonsillomedullary segment (n=1), and the telovelotonsillary segment (n=5) of the PICA. Technical feasibility, procedure related complications, angiographic results, follow-up diagnostic imaging, and clinical outcome were evaluated. RESULTS: In all cases, endovascular treatment was successful, with complete occlusion of the aneurysm with proximal parent artery preservation at the final postprocedural angiogram. Procedure related complications were not observed. One patient with a poor clinical condition at admission died during the initial hospital stay due to extensive subarachnoid and intraventricular hemorrhage. No rebleeding or recanalization was noted during follow-up. Two patients had a residual moderate to severe disability at follow-up. Favorable outcomes, with no or mild disability, were observed in four of the surviving patients. CONCLUSIONS: Angiographic, diagnostic imaging, and clinical results of our small series indicate that Onyx embolization of dissecting distal PICA aneurysms with parent artery preservation is an effective option with acceptable morbidity and mortality rate, in those cases in which surgical clipping or endovascular coiling of the aneurysmal sac is not suitable.


Subject(s)
Aortic Dissection/therapy , Cerebellum/blood supply , Dimethyl Sulfoxide/administration & dosage , Embolization, Therapeutic/methods , Intracranial Aneurysm/therapy , Polyvinyls/administration & dosage , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Cerebellum/diagnostic imaging , Cerebral Angiography , Female , Follow-Up Studies , Humans , Intracranial Aneurysm/diagnostic imaging , Male , Middle Aged , Retrospective Studies
9.
J Neurointerv Surg ; 7(9): 634-40, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25051964

ABSTRACT

BACKGROUND: Anterior circulation perforating artery aneurysms including anterior choroidal artery and lenticulostriate artery aneurysms are rare. Injury to these vessels can lead to severe debilitating symptoms. OBJECTIVE: To present a new approach to treatment using flow diversion technology. METHODS: Patients treated with a Pipeline embolization device (PED) for perforator artery aneurysms at our institution between June 2012 and May 2013 were identified and included in our retrospective analysis. We evaluated patient vascular risk factors; family history of aneurysms; aneurysm characteristics; National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) on admission; and angiography follow-up and patient clinical outcome at discharge, 6 months, and 1 year. RESULTS: We included four patients with a mean age of 59.8 years. Two patients had a positive family history of aneurysms. Patient vascular risk factors included smoking, dyslipidemia, and hypertension. All patients presented with a NIHSS and mRS of 0 on admission. Aneurysms were located at the anterior choroidal (n=2) or lenticulostriate artery (n=2) and were treated with a single PED. No periprocedural or postprocedural complications occurred. The patients were discharged with no change in NHISS or mRS score. Six-month and 1-year follow-up angiography showed complete aneurysm occlusion. Mild intimal hyperplasia was seen in 2 cases at 6 months, but was resolved at the 1-year follow-up. No re-treatment was necessary. NIHSS and mRS remained 0 at follow-up time points. CONCLUSIONS: Our preliminary results show that flow diversion technology is an effective and safe therapy for complex, hard-to-treat aneurysms in perforating arteries. Larger studies with long-term follow-up are needed to validate our promising results.


Subject(s)
Intracranial Aneurysm/surgery , Stents , Aged , Angiography, Digital Subtraction , Cerebral Angiography , Embolization, Therapeutic , Female , Follow-Up Studies , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Male , Middle Aged , Retrospective Studies , Stents/adverse effects , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...