Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JTCVS Open ; 8: 193-202, 2021 Dec.
Article in English | MEDLINE | ID: mdl-36004117

ABSTRACT

Objectives: Bioprosthetic valve deterioration remains a major limitation following aortic valve replacement. Favorable results have been reported with an autologous pericardium aortic valve neocuspidization. Methods: Seventy patients (31 women and 39 men) (mean age, 62 ± 12 years) with aortic stenosis (n = 52 [74%]) or aortic regurgitation (n = 18 [26%]) underwent the aortic valve neocuspidization procedure. Thirty-four patients (49%) had a tricuspid valve, 35 (50%) had a bicuspid valve, and 1 (1%) had a monocuspid valve. European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons scores were, respectively, 2.2% ± 2% and 2.0% ± 1.8%. Four patients (6%) had active endocarditis and 2 (3%) had endocarditis sequelae. One patient (1%) had fibroelastoma. A combined procedure was performed in 33 patients (46%). Results: The follow-up period was 24 ± 12 months. One patient (1%) died in hospital and 1 patient (1%) underwent conventional valve replacement for significant aortic regurgitation. Postoperative peak and mean pressure gradients were respectively 14 ± 5 and 8 ± 3 mm Hg. Aortic valve area was 2.5 ± 0.6 cm2. During follow-up, no patients died. Reintervention occurred in 2 patients (3%). At last follow-up, peak pressure gradient was 13 ± 7 mm Hg, mean pressure gradient was 7 ± 4 mm Hg, and aortic valve area was 2.3 ± 0.7 cm2. There was 1 recurrence of moderate aortic stenosis (1%). All patients were in New York Heart Association functional class I (90%) or II (10%). Freedom from major valve-related events was 92.1%, (98.5% for death, 95.2% for reintervention, and 95.2% for endocarditis). Conclusions: In our experience, the midterm outcomes of the aortic valve neocuspidization procedure with autologous glutaraldehyde fixed pericardium were acceptable for survival, operative risk and valve-related complications, for our all-comer patient population with various aortic valve diseases.

2.
Prev Med ; 34(2): 215-20, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11817917

ABSTRACT

BACKGROUND: We examined whether making smokers aware that they had developed peripheral atherosclerosis would improve smoking cessation. METHODS: Smokers selected from the general population were randomly allocated to undergo high-resolution B-mode ultrasonography of their carotid and femoral arteries. All smokers received quit-smoking counseling. Smokers with > or =1 atherosclerotic plaque were given two photographs of a plaque with a relevant explanation. Quit rates were assessed by telephone 6 months later. RESULTS: Seventy-nine smokers did not undergo ultrasonography (A). Among the 74 smokers submitted to ultrasonography, 20 had no plaque (B) and 54 had > or =1 plaque (C). Quit rates were, respectively, 6.3, 5.0, and 22.2% in groups A, B, and C. Quit rates were higher in smokers submitted to ultrasonography (B + C vs A; P = 0.031) and in those receiving photographs (C vs A + B; P = 0.003). Smoking cessation was independently associated with intervention C (OR = 6.2; 95% CI = 1.8-21) and a white-collar job but not with age or gender. CONCLUSIONS: Providing smokers with photographs demonstrating atherosclerosis on their own person was an effective adjunct to physician's advice to quit smoking. Since ultrasonography is used increasingly often in clinical practice for cardiovascular risk stratification, this can provide an additional opportunity and means to deter smokers from smoking.


Subject(s)
Arteriosclerosis/diagnostic imaging , Audiovisual Aids , Health Behavior , Patient Education as Topic/methods , Smoking Cessation , Adult , Counseling , Female , Humans , Male , Middle Aged , Seychelles , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...