Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 22832, 2023 12 21.
Article in English | MEDLINE | ID: mdl-38129569

ABSTRACT

A proof of principle biosensor for the Brucella abortus recognition onsite is presented. The system is based on a plasmonic optical fiber probe functionalized with an oriented antibody layer immobilized on a short polyethyleneglycol (PEG) interface through carbodiimide chemistry and protein G as an intermediate layer. The biosensor is inserted in a holder built in 3D printing technology, obtaining a custom holder useful for housing the sample to be measured and the equipment. The removable sensor chip is a low-cost Surface Plasmon Resonance (SPR) platform based on D-shaped plastic optical fibers (POFs), built-in in 3D printed connectors, used here for the first time to detect bacteria via a bio-receptor layer specific for its membrane protein. The performances of the biosensor in Brucella abortus recognition are tested by using two different SPR-POF probes combined with the same bio-receptor layer. The best sensor configuration has presented a sensitivity at low concentrations of one order of magnitude greater than the other. A limit of detection (LoD) of 2.8 bacteria/mL is achieved well competitive with other systems but without the need for amplification or special sample treatments. Specificity has been tested using Salmonella bacteria, and reproducibility, regenerability and stability are moreover evaluated. These experimental results pave the way for building an efficient and specific biosensor system for Brucella abortus detection onsite and in a few minutes. Moreover, the proposed POF-based SPR biosensor device, with respect to the already available technologies, could be a Point-of-care-test (POCT), simple to use, small-size and portable, low-cost, don't necessary of a microfluidic system, and can be connected to the Internet (IoT).


Subject(s)
Biosensing Techniques , Surface Plasmon Resonance , Surface Plasmon Resonance/methods , Brucella abortus , Reproducibility of Results , Biosensing Techniques/methods , Optical Fibers
2.
Colloids Surf B Biointerfaces ; 231: 113577, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37797466

ABSTRACT

A successful immunosensor is characterized by a proper antibody immobilization and orientation in order to enhance the antigen recognition. In this work, a thorough characterization of the antibody functionalized gold surface is performed to set up the best conditions to implement in an optical platform for the detection of Brucella sp. Two different strategies are evaluated, based on a random immobilization and on an oriented one: a direct antibody immobilization on carboxylic mixed polyethylene (PEG) self-assembled monolayer (SAM) or only carboxylic PEG SAM interface is compared to an oriented immobilization on a layer of protein G on the same PEG SAM interfaces. X-ray Photoelectron Spectroscopy (XPS), Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and contact angle (CA) are used to chemically characterize the gold functionalized surface and ToF-SIMS is also used to confirm the right antibody orientation. Optical characterization is applied to monitor the functionalization steps and fluorescence measurements are used to set up the proper experimental conditions and also to detect Brucella bacteria on the surface. Best results are obtained with a 10 ng/µl incubation solution of antibody immobilized, in an oriented way, on a mixed PEG SAM interface.


Subject(s)
Biosensing Techniques , Brucella , Surface Plasmon Resonance/methods , Biosensing Techniques/methods , Gold/chemistry , Immunoassay/methods , Surface Properties
3.
Sensors (Basel) ; 23(12)2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37420716

ABSTRACT

In this work, Fe2O3 was investigated as a doping agent for poly(methyl methacrylate) (PMMA) in order to enhance the plasmonic effect in sensors based on D-shaped plastic optical fibers (POFs). The doping procedure consists of immerging a premanufactured POF sensor chip in an iron (III) solution, avoiding repolymerization and its related disadvantages. After treatment, a sputtering process was used to deposit a gold nanofilm on the doped PMMA in order to obtain the surface plasmon resonance (SPR). More specifically, the doping procedure increases the refractive index of the POF's PMMA in contact with the gold nanofilm, improving the SPR phenomena. The doping of the PMMA was characterized by different analyses in order to determine the effectiveness of the doping procedure. Moreover, experimental results obtained by exploiting different water-glycerin solutions have been used to test the different SPR responses. The achieved bulk sensitivities confirmed the improvement of the plasmonic phenomenon with respect to a similar sensor configuration based on a not-doped PMMA SPR-POF chip. Finally, doped and non-doped SPR-POF platforms were functionalized with a molecularly imprinted polymer (MIP), specific for the bovine serum albumin (BSA) detection, to obtain dose-response curves. These experimental results confirmed an increase in binding sensitivity for the doped PMMA sensor. Therefore, a lower limit of detection (LOD), equal to 0.04 µM, has been obtained in the case of the doped PMMA sensor when compared to the one calculated for the not-doped sensor configuration equal to about 0.09 µM.


Subject(s)
Plastics , Polymers , Polymethyl Methacrylate , Optical Fibers , Ferric Compounds , Surface Plasmon Resonance/methods , Gold
4.
Ital J Pediatr ; 47(1): 221, 2021 Nov 06.
Article in English | MEDLINE | ID: mdl-34742330

ABSTRACT

BACKGROUND: With the gradual resumption of sports activities after the lock-down period for coronavirus pandemic, a new problem is emerging: Allow all athletes to be able to return to compete after SARS-CoV-2 infection in total safety. Several protocols have been proposed for healed athletes but all of them have been formulated for the adult population. The aim of the present study is to evaluate the adequacy of Italian practical recommendations for return-to-paly, in order to exclude cardiorespiratory complications due to COVID-19 in children and adolescents. METHODS: Between April 2020 and January 2021 the Italian Sports Medical Federation formulated cardiorespiratory protocols to be applied to athletes recovered from SARS-CoV-2 infection. The protocols take into account the severity of the infection. Protocols include lung function tests, cardiopulmonary exercise test, echocardiographic evaluation, blood chemistry tests. RESULTS: From September 2020 to February 2021, 45 children and adolescents (aged from 9 to 18 years; male = 26) with previous SARS-CoV-2 infection were evaluated according to the protocols in force for adult. 55.5% of the subjects (N = 25) reported an asymptomatic infection; 44.5% reported a mild symptomatic infection. Results of lung function test have exceeded the limit of 80% of the theoretical value in all patients. The cardiorespiratory capacity of all patients was within normal limits (average value of maximal oxigen uptake 41 ml/kg/min). No arrhythmic events or reduction in the ejection fraction were highlighted. CONCLUSION: The data obtained showed that, in the pediatric population, mild coronavirus infection does not cause cardiorespiratory complications in the short and medium term. Return to play after Coronavirus infection seems to be safe but it will be necessary to continue with the data analysis in order to modulate and optimize the protocols especially in the pediatric field.


Subject(s)
COVID-19/complications , Return to Sport , Adolescent , Age Factors , COVID-19/physiopathology , COVID-19/therapy , Cardiorespiratory Fitness , Child , Clinical Protocols , Female , Humans , Italy , Male , Recovery of Function , Respiratory Function Tests , Time Factors
5.
Nanomaterials (Basel) ; 11(8)2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34443792

ABSTRACT

In a specific biosensing application, a nanoplasmonic sensor chip has been tested by an experimental setup based on an aluminum holder and two plastic optical fibers used to illuminate and collect the transmitted light. The studied plasmonic probe is based on gold nanograting, realized on the top of a Poly(methyl methacrylate) (PMMA) chip. The PMMA substrate could be considered as a transparent substrate and, in such a way, it has been already used in previous work. Alternatively, here it is regarded as a slab waveguide. In particular, we have deposited upon the slab surface, covered with a nanograting, a synthetic receptor specific for bovine serum albumin (BSA), to test the proposed biosensing approach. Exploiting this different experimental configuration, we have determined how the orientation of the nanostripes forming the grating pattern, with respect to the direction of the input light (longitudinal or orthogonal), influences the biosensing performances. For example, the best limit of detection (LOD) in the BSA detection that has been obtained is equal to 23 pM. Specifically, the longitudinal configuration is characterized by two observable plasmonic phenomena, each sensitive to a different BSA concentration range, ranging from pM to µM. This aspect plays a key role in several biochemical sensing applications, where a wide working range is required.

6.
Sensors (Basel) ; 21(5)2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33804378

ABSTRACT

The rapid spread of the Coronavirus Disease 2019 (COVID-19) pandemic, caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pathogen has generated a huge international public health emergency. Currently the reference diagnostic technique for virus determination is Reverse Transcription Polymerase Chain Reaction (RT-PCR) real time analysis that requires specialized equipment, reagents and facilities and typically 3-4 h to perform. Thus, the realization of simple, low-cost, small-size, rapid and point-of-care diagnostics tests has become a global priority. In response to the current need for quick, highly sensitive and on-site detection of the SARS-CoV-2 virus in several aqueous solutions, a specific molecularly imprinted polymer (MIP) receptor has been designed, realized, and combined with an optical sensor. More specifically, the proof of concept of a SARS-CoV-2 sensor has been demonstrated by exploiting a plasmonic plastic optical fiber sensor coupled with a novel kind of synthetic MIP nano-layer, especially designed for the specific recognition of Subunit 1 of the SARS-CoV-2 Spike protein. First, we have tested the effectiveness of the developed MIP receptor to bind the Subunit 1 of the SARS-CoV-2 spike protein, then the results of preliminary tests on SARS-CoV-2 virions, performed on samples of nasopharyngeal (NP) swabs in universal transport medium (UTM) and physiological solution (0.9% NaCl), were compared with those obtained with RT-PCR. According to these preliminary results, the sensitivity of the proposed optical-chemical sensor proved to be higher than the RT-PCR one. Furthermore, a relatively fast response time (about 10 min) to the virus was obtained without the use of additional reagents.


Subject(s)
COVID-19/diagnosis , Molecularly Imprinted Polymers , Optical Fibers , SARS-CoV-2/isolation & purification , Humans , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus
7.
Sci Rep ; 10(1): 11154, 2020 07 07.
Article in English | MEDLINE | ID: mdl-32636434

ABSTRACT

Different lines of evidence indicate that monitoring the blood levels of therapeutic antibodies, characterized by high inter-individual variability, can help to optimize clinical decision making, improving patient outcomes and reducing costs with these expensive treatments. A surface plasmon resonance (SPR)-based immunoassay has recently been shown to allow highly reliable and robust monitoring of serum concentrations of infliximab, with significant advantages over classical ELISA. The next level of advancement would be the availability of compact and transportable SPR devices suitable for easy, fast and cheap point-of-care analysis. Here we report the data obtained with recently developed, cost-effective, optical-fibre-based SPR sensors (SPR-POF), which allow the construction of a compact miniaturized system for remote sensing. We carried out an extensive characterization of infliximab binding to an anti-infliximab antibody immobilized on the SPR-POF sensor surface. The present proof-of-principle studies demonstrate the feasibility of the proposed SPR-POF platform for the specific detection of infliximab, in both buffer and human serum, and pave the way for further technological improvements.


Subject(s)
Antibodies/blood , Biosensing Techniques/methods , Surface Plasmon Resonance/methods , Antibodies/therapeutic use , Biosensing Techniques/instrumentation , Enzyme-Linked Immunosorbent Assay , Humans , Optical Fibers , Remote Sensing Technology/instrumentation , Remote Sensing Technology/methods , Reproducibility of Results , Sensitivity and Specificity , Surface Plasmon Resonance/instrumentation
8.
Sensors (Basel) ; 18(6)2018 Jun 05.
Article in English | MEDLINE | ID: mdl-29874860

ABSTRACT

A novel Molecularly Imprinted Polymer (MIP) able to bind perfluorinated compounds, combined with a surface plasmon resonance (SPR) optical fiber platform, is presented. The new MIP receptor has been deposited on a D-shaped plastic optical fiber (POF) covered with a photoresist buffer layer and a thin gold film. The experimental results have shown that the developed SPR-POF-MIP sensor makes it possible to selectively detect the above compounds. In this work, we present the results obtained with perfluorooctanoate (PFOA) compound, and they hold true when obtained with a perfluorinated alkylated substances (PFAs) mixture sample. The sensor's response is the same for PFOA, perfluorooctanesulfonate (PFOS) or PFA contaminants in the C4⁻C11 range. We have also tested a sensor based on a non-imprinted polymer (NIP) on the same SPR in a D-shaped POF platform. The limit of detection (LOD) of the developed chemical sensor was 0.13 ppb. It is similar to the one obtained by the configuration based on a specific antibody for PFOA/PFOS exploiting the same SPR-POF platform, already reported in literature. The advantage of an MIP receptor is that it presents a better stability out of the native environment, very good reproducibility, low cost and, furthermore, it can be directly deposited on the gold layer, without modifying the metal surface by functionalizing procedures.

SELECTION OF CITATIONS
SEARCH DETAIL
...