1.
Ultrasound Med Biol ; 50(2): 285-294, 2024 02.
Article in English | MEDLINE | ID: mdl-38036310

ABSTRACT

OBJECTIVE: Described here is the development of an ultrasound matrix transducer prototype for high-frame-rate 3-D intra-cardiac echocardiography. METHODS: The matrix array consists of 16 × 18 lead zirconate titanate elements with a pitch of 160 µm × 160 µm built on top of an application-specific integrated circuit that generates transmission signals and digitizes the received signals. To reduce the number of cables in the catheter to a feasible number, we implement subarray beamforming and digitization in receive and use a combination of time-division multiplexing and pulse amplitude modulation data transmission, achieving an 18-fold reduction. The proposed imaging scheme employs seven fan-shaped diverging transmit beams operating at a pulse repetition frequency of 7.7 kHz to obtain a high frame rate. The performance of the prototype is characterized, and its functionality is fully verified. RESULTS: The transducer exhibits a transmit efficiency of 28 Pa/V at 5 cm per element and a bandwidth of 60% in transmission. In receive, a dynamic range of 80 dB is measured with a minimum detectable pressure of 10 Pa per element. The element yield of the prototype is 98%, indicating the efficacy of the manufacturing process. The transducer is capable of imaging at a frame rate of up to 1000 volumes/s and is intended to cover a volume of 70° × 70° × 10 cm. CONCLUSION: These advanced imaging capabilities have the potential to support complex interventional procedures and enable full-volumetric flow, tissue, and electromechanical wave tracking in the heart.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Phantoms, Imaging , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Heart , Transducers , Ultrasonography/methods , Equipment Design
2.
Sensors (Basel) ; 22(23)2022 Nov 30.
Article in English | MEDLINE | ID: mdl-36502021

ABSTRACT

Ultrasonic flow meters (UFMs) based on transducer arrays offer several advantages. With electronic beam steering, it is possible to tune the steering angle of the beam for optimal signal-tonoise ratio (SNR) upon reception. Moreover, multiple beams can be generated to propagate through different travel paths, covering a wider section of the flow profile. Furthermore, in a clamp-on configuration, UFMs based on transducer arrays can perform self-calibration. In this manner, userinput is minimized and measurement repeatability is increased. In practice, transducer array elements may break down. This could happen due to aging, exposure to rough environments, and/or rough mechanical contact. As a consequence of inactive array elements, the measured transit time difference contains two offsets. One offset originates from non-uniform spatial sampling of the generated wavefield. Another offset originates from the ill-defined beam propagating through a travel path different from the intended one. In this paper, an algorithm is proposed that corrects for both of these offsets. The algorithm also performs a filtering operation in the frequency-wavenumber domain of all spurious (i.e., flow-insensitive) wave modes. The advantage of implementing the proposed algorithm is demonstrated on simulations and measurements, showing improved accuracy and precision of the transit time differences compared to the values obtained when the algorithm is not applied. The proposed algorithm can be implemented in both in-line and clamp-on configuration of UFMs based on transducer arrays.


Subject(s)
Algorithms , Transducers , Ultrasonography , Ultrasonics
3.
Sensors (Basel) ; 22(24)2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36560168

ABSTRACT

High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for channel reduction. However, the fabrication of such a transducer integrated with one very large ASIC is very challenging and expensive. In this study, we develop a prototype matrix transducer mounted on top of multiple identical ASICs in a tiled configuration. The matrix was designed to have 7680 piezoelectric elements with a pitch of 300 µm × 150 µm integrated with an array of 8 × 1 tiled ASICs. The performance of the prototype is characterized by a series of measurements. The transducer exhibits a uniform behavior with the majority of the elements working within the -6 dB sensitivity range. In transmit, the individual elements show a center frequency of 7.5 MHz, a -6 dB bandwidth of 45%, and a transmit efficiency of 30 Pa/V at 200 mm. In receive, the dynamic range is 81 dB, and the minimum detectable pressure is 60 Pa per element. To demonstrate the imaging capabilities, we acquired 3D images using a commercial wire phantom.


Subject(s)
Imaging, Three-Dimensional , Transducers , Equipment Design , Ultrasonography/methods , Imaging, Three-Dimensional/methods , Phantoms, Imaging , Carotid Arteries/diagnostic imaging
4.
Sensors (Basel) ; 22(14)2022 Jul 06.
Article in English | MEDLINE | ID: mdl-35890749

ABSTRACT

Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe wall until the maximum amplitude of the relevant acoustic pulse is obtained. This process is time-consuming and operator-dependent. Next to this, at least five parameters of the pipe and the liquid need to be provided manually to compute the flow speed. In this work, a method is proposed to obtain the five parameters of the pipe and the liquid required to compute the flow speed. The method consists of obtaining the optimal angles for different wave travel paths by varying the steering angle of the emitted acoustic beam systematically. Based on these optimal angles, a system of equations is built and solved to extract the desired parameters. The proposed method was tested experimentally with a custom-made clamp-on UFM consisting of two linear arrays placed on a water-filled stainless steel pipe. The obtained parameters of the pipe and the liquid correspond very well with the expected (nominal) values. Furthermore, the performed experiment also demonstrates that a clamp-on UFM based on transducer arrays can achieve self-alignment without the need to manually move the transducers.


Subject(s)
Transducers , Ultrasonics , Acoustics , Equipment Design
5.
Article in English | MEDLINE | ID: mdl-35749331

ABSTRACT

Common clamp-on ultrasonic flow meters consist of two single-element transducers placed on the pipe wall. Flow speed is measured noninvasively, i.e., without interrupting the flow and without perforating the pipe wall, which also minimizes safety risks and avoids pressure drops inside the pipe. However, before metering, the transducers have to be carefully positioned along the pipe axis to correctly align the acoustic beams and obtain a well-calibrated flowmeter. This process is done manually, is dependent on the properties of the pipe and the liquid, does not account for pipe imperfections, and becomes troublesome on pipelines with an intricate shape. Matrix transducer arrays are suitable to dynamically steer acoustic beams and realize self-alignment upon reception, without user input. In this work, the design of a broadband 37×17 matrix array (center frequency of 1 MHz) to perform clamp-on ultrasonic flow measurements over a wide range of liquids ( c=1000-2000 m/s, α ≤ 1 dB/MHz · cm) and pipe sizes is presented. Three critical aspects were assessed: efficiency, electronic beam steering, and wave mode conversion in the pipe wall. A prototype of a proof-of-concept flowmeter consisting of two 36-element linear arrays (center frequency of 1.1 MHz) was fabricated and placed on a 1-mm-thick, 40-mm inner diameter stainless steel pipe in a custom-made flow loop filled with water. At resonance, simulated and measured efficiencies in water of the linear arrays compared well: 0.88 and 0.81 kPa/V, respectively. Mean flow measurements were achieved by electronic beam steering of the acoustic beams and using both compressional and shear waves generated in the pipe wall. Correlation coefficients of between measured and reference flow speeds were obtained, thus showing the operational concept of an array-based clamp-on ultrasonic flowmeter.


Subject(s)
Transducers , Ultrasonics , Acoustics , Equipment Design , Water
6.
Article in English | MEDLINE | ID: mdl-35759589

ABSTRACT

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is normally treated by RF ablation. Intracardiac echography (ICE) is widely employed during RF ablation procedures to guide the electrophysiologist in navigating the ablation catheter, although only 2-D probes are currently clinically used. A 3-D ICE catheter would not only improve visualization of the atrium and ablation catheter, but it might also provide the 3-D mapping of the electromechanical wave (EW) propagation pattern, which represents the mechanical response of cardiac tissue to electrical activity. The detection of this EW needs 3-D high-frame-rate imaging, which is generally only realizable in tradeoff with channel count and image quality. In this simulation-based study, we propose a high volume rate imaging scheme for a 3-D ICE probe design that employs 1-D micro-beamforming in the elevation direction. Such a probe can achieve a high frame rate while reducing the channel count sufficiently for realization in a 10-Fr catheter. To suppress the grating-lobe (GL) artifacts associated with micro-beamforming in the elevation direction, a limited number of fan-shaped beams with a wide azimuthal and narrow elevational opening angle are sequentially steered to insonify slices of the region of interest. An angular weighted averaging of reconstructed subvolumes further reduces the GL artifacts. We optimize the transmit beam divergence and central frequency based on the required image quality for EW imaging (EWI). Numerical simulation results show that a set of seven fan-shaped transmission beams can provide a frame rate of 1000 Hz and a sufficient spatial resolution to visualize the EW propagation on a large 3-D surface.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Artifacts , Atrial Fibrillation/surgery , Echocardiography/methods , Heart Atria/diagnostic imaging , Humans
7.
Article in English | MEDLINE | ID: mdl-34506280

ABSTRACT

Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-to-noise ratio (SNR) is achieved. This distance depends on the sound speed, thickness, and diameter of the pipe and on the sound speed of the liquid. However, these parameters are either known with low accuracy or completely unknown during positioning, making it a manual and troublesome process. Furthermore, even when sensor positioning is done properly, uncertainty about the mentioned parameters, and therefore on the path of the acoustic beams, limits the final accuracy of flow measurements. In this research, we address these issues using an ultrasonic clamp-on flow meter consisting of two matrix arrays, which enables the measurement of pipe and liquid parameters by the flow meter itself. Automatic parameter extraction, combined with the beam-steering capabilities of transducer arrays, yields a sensor capable of compensating for pipe imperfections. Three parameter extraction procedures are presented. In contrast to similar literature, the procedures proposed here do not require that the medium be submerged nor do they require a priori information about it. First, axial Lamb waves are excited along the pipe wall and recorded with one of the arrays. A dispersion curve-fitting algorithm is used to extract bulk sound speeds and wall thickness of the pipe from the measured dispersion curves. Second, circumferential Lamb waves are excited, measured, and corrected for dispersion to extract the pipe diameter. Third, pulse-echo measurements provide the sound speed of the liquid. The effectiveness of the first two procedures has been evaluated using simulated and measured data of stainless steel and aluminum pipes, and the feasibility of the third procedure has been evaluated using simulated data.


Subject(s)
Acoustics , Ultrasonics , Algorithms , Sound , Transducers
8.
Ultrasonics ; 116: 106476, 2021 Jun 02.
Article in English | MEDLINE | ID: mdl-34098419

ABSTRACT

Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would translate into more information to estimate the flow and therefore a higher precision relative to the linear case. In this work, we investigate how the generated harmonics can be used to measure flow. Measurements in a custom-made flow loop and simulations using the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation will show that the second harmonic component provides similar transit time differences to those obtained from the fundamental component, their linear combination results in more precise flow measurements compared to the estimations with the fundamental component alone.

9.
J Acoust Soc Am ; 147(4): 2670, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32359301

ABSTRACT

During ultrasonic clamp-on flow metering, Lamb waves propagating in the pipe wall may limit the measurement accuracy by introducing absolute errors in the flow estimates. Upon reception, these waves can interfere with the up and downstream waves refracting from the liquid, and disturb the measurement of the transit time difference that is used to obtain the flow speed. Thus, suppression of the generation of Lamb waves might directly increase the accuracy of a clamp-on flow meter. Existing techniques apply to flow meters with single element transducers. This paper considers the application of transducer arrays and presents a method to achieve a predefined amount of suppression of these spurious Lamb waves based on appropriate amplitude weightings of the transducer elements. Finite element simulations of an ultrasonic clamp-on flow measurement setting will be presented to show the effect of array aperture control on the suppression of the Lamb waves in a 1-mm-thick stainless steel pipe wall. Furthermore, a proof-of-principle experiment will be shown that demonstrates a good agreement with the simulations.

10.
Sensors (Basel) ; 21(1)2020 Dec 29.
Article in English | MEDLINE | ID: mdl-33383681

ABSTRACT

This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a programmable switch matrix that allowed selected transducer elements in each row to be connected to a transmit and receive channel of an imaging system. This made the probe operate like an electronically translatable linear array, allowing large-aperture matrix arrays to be interfaced with a manageable number of system channels. This paper presents a second-generation ASIC that employed an improved switch design to minimize clock feedthrough and charge-injection effects of high-voltage metal-oxide-semiconductor field-effect transistors (HV MOSFETs), which in the first-generation ASIC caused parasitic transmissions and associated imaging artifacts. The proposed switch controller, implemented with cascaded non-overlapping clock generators, generated control signals with improved timing to mitigate the effects of these non-idealities. Both simulation results and electrical measurements showed a 20 dB reduction of the switching artifacts. In addition, an acoustic pulse-echo measurement successfully demonstrated a 20 dB reduction of imaging artifacts.


Subject(s)
Artifacts , Carotid Arteries/diagnostic imaging , Transducers , Ultrasonography , Equipment Design , Imaging, Three-Dimensional
11.
Article in English | MEDLINE | ID: mdl-31449014

ABSTRACT

This article quantitatively analyzes the impact of bit errors in digitized RF data on ultrasound image quality. The quality of B-mode images in both linear array and phased array imaging is evaluated by means of three objective image quality metrics: peak signal-to-noise ratio, structural similarity index, and contrast-to-noise ratio, when bit errors are introduced to the RF data with different bit-error rates (BERs). The effectiveness of coding schemes for forward error detection and correction to improve the image quality is also studied. The results show that ultrasound imaging is inherently resilient to high BER. The image quality suffers unnoticeable degradation for BER lower than 1E-6. Simple 1-bit parity coding with 9% added redundancy helps to retain similar image quality for BER up to 1E-4, and Hamming coding with 33.3% added redundancy allows the BER to increase to 1E-3. These results can serve as a guideline in the datalink design for ultrasound probes with in-probe receive digitization. With much more relaxed BER requirements than in typical datalinks, the design can be optimized by allowing fewer cables with higher data rate per cable or lower power consumption with the same cable count.

12.
Ultrasound Med Biol ; 44(10): 2143-2154, 2018 10.
Article in English | MEDLINE | ID: mdl-30072206

ABSTRACT

This paper presents the design, fabrication and characterization of a miniature PZT-on-CMOS matrix transducer for real-time pediatric 3-dimensional (3D) transesophageal echocardiography (TEE). This 3D TEE probe consists of a 32 × 32 array of PZT elements integrated on top of an Application Specific Integrated Circuit (ASIC). We propose a partitioned transmit/receive array architecture wherein the 8 × 8 transmitter elements, located at the centre of the array, are directly wired out and the remaining receive elements are grouped into 96 sub-arrays of 3 × 3 elements. The echoes received by these sub-groups are locally processed by micro-beamformer circuits in the ASIC that allow pre-steering up to ±37°. The PZT-on-CMOS matrix transducer has been characterized acoustically and has a centre frequency of 5.8 MHz, -6 dB bandwidth of 67%, a transmit efficiency of 6 kPa/V at 30 mm, and a receive dynamic range of 85 dB with minimum and maximum detectable pressures of 5 Pa and 84 kPa respectively. The properties are very suitable for a miniature pediatric real-time 3D TEE probe.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/instrumentation , Echocardiography, Transesophageal/methods , Phantoms, Imaging , Signal Processing, Computer-Assisted , Transducers , Acoustics , Child , Echocardiography, Three-Dimensional/instrumentation , Equipment Design , Humans , Pediatrics/methods
13.
Article in English | MEDLINE | ID: mdl-30047876

ABSTRACT

Intravascular ultrasound (IVUS) is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking IVUS (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2-D array transducers, which present major challenges in reducing cable count and device integration. In this work, we present an 80-element lead zirconium titanate matrix ultrasound transducer for FL-IVUS imaging with a front-end application-specific integrated circuit (ASIC) requiring only four cables. After investigating optimal transducer designs, we fabricated the matrix transducer consisting of 16 transmit (TX) and 64 receive (RX) elements arranged on top of an ASIC having an outer diameter of 1.5 mm and a central hole of 0.5 mm for a guidewire. We modeled the transducer using finite-element analysis and compared the simulation results to the values obtained through acoustic measurements. The TX elements showed uniform behavior with a center frequency of 14 MHz, a -3-dB bandwidth of 44%, and a transmit sensitivity of 0.4 kPa/V at 6 mm. The RX elements showed center frequency and bandwidth similar to the TX elements, with an estimated receive sensitivity of /Pa. We successfully acquired a 3-D FL image of three spherical reflectors in water using delay-and-sum beamforming and the coherence factor method. Full synthetic-aperture acquisition can be achieved with frame rates on the order of 100 Hz. The acoustic characterization and the initial imaging results show the potential of the proposed transducer to achieve 3-D FL-IVUS imaging.

14.
Ultrasound Med Biol ; 44(9): 2025-2042, 2018 09.
Article in English | MEDLINE | ID: mdl-30037476

ABSTRACT

We describe a 3-D multiline parallel beamforming scheme for real-time volumetric ultrasound imaging using a prototype matrix transesophageal echocardiography probe with diagonally diced elements and separated transmit and receive arrays. The elements in the smaller rectangular transmit array are directly wired to the ultrasound system. The elements of the larger square receive aperture are grouped in 4 × 4-element sub-arrays by micro-beamforming in an application-specific integrated circuit. We propose a beamforming sequence with 85 transmit-receive events that exhibits good performance for a volume sector of 60°â€¯× 60°. The beamforming is validated using Field II simulations, phantom measurements and in vivo imaging. The proposed parallel beamforming achieves volume rates up to 59 Hz and produces good-quality images by angle-weighted combination of overlapping sub-volumes. Point spread function, contrast ratio and contrast-to-noise ratio in the phantom experiment closely match those of the simulation. In vivo 3-D imaging at 22-Hz volume rate in a healthy adult pig clearly visualized the cardiac structures, including valve motion.


Subject(s)
Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/instrumentation , Echocardiography, Transesophageal/methods , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted/instrumentation , Animals , Models, Animal , Phantoms, Imaging , Reproducibility of Results , Swine , Transducers
15.
Ultrasound Med Biol ; 42(5): 1239-43, 2016 May.
Article in English | MEDLINE | ID: mdl-26856788

ABSTRACT

Intravascular photoacoustic (IVPA) imaging can visualize the coronary atherosclerotic plaque composition on the basis of the optical absorption contrast. Most of the photoacoustic (PA) energy of human coronary plaque lipids was found to lie in the frequency band between 2 and 15 MHz requiring a very broadband transducer, especially if a combination with intravascular ultrasound is desired. We have developed a broadband polyvinylidene difluoride (PVDF) transducer (0.6 × 0.6 mm, 52 µm thick) with integrated electronics to match the low capacitance of such a small polyvinylidene difluoride element (<5 pF/mm(2)) with the high capacitive load of the long cable (∼100 pF/m). The new readout circuit provides an output voltage with a sensitivity of about 3.8 µV/Pa at 2.25 MHz. Its response is flat within 10 dB in the range 2 to 15 MHz. The root mean square (rms) output noise level is 259 µV over the entire bandwidth (1-20 MHz), resulting in a minimum detectable pressure of 30 Pa at 2.25 MHz.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Micro-Electrical-Mechanical Systems/instrumentation , Polyvinyls/chemistry , Signal Processing, Computer-Assisted/instrumentation , Transducers , Ultrasonography, Interventional/instrumentation , Amplifiers, Electronic , Equipment Design , Equipment Failure Analysis , Image Enhancement/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Polyvinyls/radiation effects , Reproducibility of Results , Sensitivity and Specificity , Systems Integration , Ultrasonic Waves , User-Computer Interface
16.
Article in English | MEDLINE | ID: mdl-26540683

ABSTRACT

This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal echocardiography (TEE) probe. It consists of an array of 9 ×12 piezoelectric elements mounted on the ASIC via an integration scheme that involves direct electrical connections between a bond-pad array on the ASIC and the transducer elements. The ASIC addresses the critical challenge of reducing cable count, and includes front-end amplifiers with adjustable gains and micro-beamformer circuits that locally process and combine echo signals received by the elements of each 3 ×3 subarray. Thus, an order-of-magnitude reduction in the number of receive channels is achieved. Dedicated circuit techniques are employed to meet the strict space and power constraints of TEE probes. The ASIC has been fabricated in a standard 0.18-µm CMOS process and consumes only 0.44 mW/channel. The prototype has been acoustically characterized in a water tank. The ASIC allows the array to be presteered across ±37° while achieving an overall dynamic range of 77 dB. Both the measured characteristics of the individual transducer elements and the performance of the ASIC are in good agreement with expectations, demonstrating the effectiveness of the proposed techniques.


Subject(s)
Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Transesophageal/instrumentation , Lead/chemistry , Signal Processing, Computer-Assisted/instrumentation , Titanium/chemistry , Transducers , Zirconium/chemistry , Equipment Design
17.
Article in English | MEDLINE | ID: mdl-22828845

ABSTRACT

There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-µm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.


Subject(s)
Algorithms , Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Transesophageal/instrumentation , Electronics/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Information Storage and Retrieval/methods , Pattern Recognition, Automated/methods , Signal Processing, Computer-Assisted/instrumentation , Transducers , Equipment Design , Equipment Failure Analysis , Image Enhancement/instrumentation , Reproducibility of Results , Sensitivity and Specificity