Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Phys Med ; 30(1): 18-24, 2014 Feb.
Article in English | MEDLINE | ID: mdl-22749733

ABSTRACT

Dental CT dose evaluations are commonly performed using thermoluminescent dosimeters (TLD) inside anthropomorphic phantoms. Radiochromic films with good sensitivity in the X-ray diagnostic field have recently been developed and are commercially available as GAFCHROMIC XR-QA. There are potential advantages in the use of radiochromic films such as a more comprehensive dosimetry thanks to the adjustable size of the film samples. The purpose of this study was to investigate the feasibility of using radiochromic films for dental CT dose evaluations. Film samples were cut with a width of 5mm and a length of 25 mm (strips), the same size as the Alderson Rando anthropomorphic phantom holes used in this study. Dental CT dose measurements were performed using simultaneously both TLD and radiochromic strips in the same phantom sites. Two equipment types were considered for dental CT examinations: a 16 slice CT and a cone beam CT. Organ equivalent doses were then obtained averaging the measurements from the sites of the same organ and effective doses were calculated using ICRP 103 weighting factors. The entire procedure was repeated four times for each CT in order to compare also the repeatability of the two dosimeter types. A linear correlation was found between the absorbed dose evaluated with radiochromic films and with TLD, with slopes of 0.930 and 0.944 (correlation r>0.99). The maximum difference between the two dosimeter's measurements was 25%, whereas the average difference was 7%. The measurement repeatability was comparable for the two dosimeters at cumulative doses above 15 mGy (estimated uncertainty at 1 sigma level of about 5%), whereas below this threshold radiochromic films show a greater dispersion of data, of about 10% at 1 sigma level. We obtained, using respectively Gafchromic and TLD measurements, effective dose values of 107 µSv and 117 µSv (i.e. difference of 8.6%) for the cone beam CT and of 523 µSv and 562 µSv (i.e. difference of 7%) for the multislice CT. This study demonstrates the feasibility of radiochromic films for dental CT dosimetry, pointing out a good agreement with the results obtained using TLD, with potential advantages and the chance of a more extensive dose investigation.


Subject(s)
Dentistry , Film Dosimetry/methods , Tomography, X-Ray Computed , Feasibility Studies , Humans , Phantoms, Imaging , Radiation Dosage
2.
Radiat Prot Dosimetry ; 157(3): 339-47, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23816980

ABSTRACT

The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be considered as representative of the level I countries, as defined by the United Nations Scientific Committee on the Effects of Atomic Radiation. The NM per-procedures effective doses were within the range of 0.018-35 mSv. A steady frequency per 10 000 inhabitants has been observed, together with a decrease for thyroid and whole-body bone scintigraphy. Myocardial and bone scintigraphy studies were the major contributors to the total collective effective dose. The mean annual collective and per-capita effective doses to the population were 15 man Sv y(-1) and 120 µSv y(-1), respectively. The NM contribution to the total per-capita effective dose accounts for 5.9 % of that due to the medical ionising radiation examinations overall.


Subject(s)
Diagnostic Imaging , Nuclear Medicine , Occupational Exposure/analysis , Radiation Monitoring , Adult , Body Burden , Female , Humans , Male , Middle Aged , Radiation Dosage , Whole-Body Counting
3.
Br J Radiol ; 85(1015): e330-8, 2012 Jul.
Article in English | MEDLINE | ID: mdl-21937611

ABSTRACT

OBJECTIVE: Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009. METHOD: Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose. RESULTS: The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose. CONCLUSION: The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009.


Subject(s)
Diagnostic Imaging/statistics & numerical data , Radiation Dosage , Radiation, Ionizing , Radiometry/methods , Adolescent , Adult , Aged , Child , Cohort Studies , Databases, Factual , Diagnostic Imaging/trends , Dose-Response Relationship, Radiation , Environmental Exposure , Female , Humans , Incidence , Italy , Male , Middle Aged , Radiography/statistics & numerical data , Radiography/trends , Radiology Department, Hospital , Reference Values , Retrospective Studies , Risk Assessment , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...