Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Liver ; 22 Suppl 2: 30-4, 2002.
Article in English | MEDLINE | ID: mdl-12220300

ABSTRACT

UNLABELLED: Albumin dialysis with the MARSystem is used in many hospitals to support excretory hepatic function in acute or acute on chronic liver failure. Potential pathogenic albumin bound substances accumulated in excretory liver insufficiency can be removed from patients blood by dialysis against albumin solution. A specific membrane enables the selective transport of albumin bound metabolites to the albumin containing dialysate compartment, where the loaded transport albumin is cleared and regenerated at the same time by adsorption columns and a second dialyser. Between 1993 and 1995 different membranes, set-ups and components in albumin dialysis were tested and led finally to the recirculating MARSystem with a modified polysulphone based membrane (P3/5S Gambro, Hechingen) and two adsorption columns (N350 and BR 350, ASAHI Medical Ltd.), which showed the best performance at this time. This first generation of MARSystems was used clinically between 1995 and 1998 with only minor changes in 15 patients with acute (n = 1) or acute deterioration of chronic liver disease in our department until the improved next generation of MARSystems has been available (MARS set and monitor, Teraklin AG, Rostock, Germany). Changes in blood tests pre/post during 95 single MARS treatments and in clinical status over treatment period were evaluated retrospectively. RESULTS: A significant decrease of albumin bound substances (average reduction during single MARS treatments: bilirubin -18%, bile acids -43.7%) as well as of water soluble metabolites (creatinine -32%, urea -31%) was observed. During extracorporeal therapy also a significant drop in platelets (- 15.4%) and a prolongation of activated prothrombin time (- 21%) was documented, whereas haemoglobin, WBC, electrolytes as well as transaminases and albumin were not affected significantly. CONCLUSION: Albumin dialysis with the first generation of MARS enables the removal of albumin bound and water soluble toxins. Unwanted side-effects and changes in laboratory tests are comparable to conventional haemodialysis (drop of platelets and prolongation of coagulation tests). The elimination of albumin bound and water soluble substances was accompanied by an improvement of clinical status.


Subject(s)
Liver Failure, Acute/therapy , Renal Dialysis , Serum Albumin/metabolism , Sorption Detoxification , Hepatitis, Alcoholic/blood , Hepatitis, Alcoholic/therapy , Humans , Liver Failure, Acute/blood , Retrospective Studies , Treatment Outcome
2.
Liver ; 22 Suppl 2: 40-2, 2002.
Article in English | MEDLINE | ID: mdl-12220302

ABSTRACT

The single pass albumin dialysis (SPAD) was reported to be an alternative to the Molecular Adsorbent Recirculating System (MARS) for the effective removal of protein bound substances in liver failure. Three SPAD experiments using different albumin concentrations and dialysate flow rates were performed. In each experiment, 1000 ml human donor plasma, spiked with 250 mg unconjugated bilirubin, 200 mg sulfobromophthalein (BSP) and 115 mg glycocholic acid (N-[3alpha,7alpha,12alpha-trihydroxy-24-oxycholan-24-yl]glycine) - a conjugated bile acid (BA), circulated in a closed loop with 150 ml/min and was dialysed against albumin solution. These substances are bound to the different binding sites of albumin and have different association constants. For the comparison, the standard MARS experiment was performed using the same plasma flow rate of 150 ml/min. Moreover, the clearances of bilirubin for MARS and SPAD during clinical treatments were calculated using own data and those reported by Seige, Kreymann, Jeschke, et al. in Transplant Proc 1999; 31: 1371-5. The concentrations of bilirubin, BSP and BA were measured in plasma and dialysate and for these substances clearances (Cl) were calculated. It is known that the elimination rate of bilirubin is not very high during albumin dialysis in comparison to other substances, like bile acids, due to the high association constant. An increase of albumin concentration or the flow rate improved the efficacy but also raised the costs substantially. In this study, we have shown that MARS is the more effective kind of albumin dialysis for the important substances like bile acids. By SPAD an improvement of efficacy can be reached only by dramatic increase of the costs. Also, the earlier experiments showed that MARS is safer because of the removal of the stabilizers, which are normally included in the commercial albumin solutions.


Subject(s)
Liver Failure/therapy , Renal Dialysis/methods , Serum Albumin/metabolism , Sorption Detoxification/methods , Bile Acids and Salts/blood , Humans , Liver Failure/blood , Treatment Outcome
3.
Metab Brain Dis ; 17(4): 463-75, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12602522

ABSTRACT

The Molecular Adsorbent Recirculating System (MARS) is a nonbiological liver support method based on the principles of dialysis, filtration, and adsorption. It allows the safe and efficient removal of both albumin-bound and water-soluble toxic metabolites, including ammonia, aromatic amino acids, tryptophan, and related phenolic and indolic products, as well as benzodiazepines. A well-documented effect of the treatment is the improvement of the hemodynamic situation of decompensated chronic patients. Systemic vascular resistance, mean arterial pressure, cerebral blood flow, and cerebral oxygen consumption increased significantly. The degree of hepatic encephalopathy decreased significantly. Increased intracranial pressure could be normalized in both chronic and fulminant liver failure. In three randomized clinical trials significant improvement of survival could be demonstrated. In a model of murine neuronal networks cultured on multi-microelectrode array plates and incubated with plasma from liver failure patients, a normalization of the spike and burst pattern could be observed, if plasma samples from MARS-treated patients before and after treatment were compared. In conclusion, MARS significantly improves central nervous system functions. It can serve as a model for the further investigation of the role of protein-bound substances in hepatic encephalopathy and cerebral hemodynamics.


Subject(s)
Brain/physiopathology , Liver Failure/therapy , Renal Dialysis , Serum Albumin/isolation & purification , Sorption Detoxification/methods , Humans
4.
Curr Opin Nephrol Hypertens ; 10(6): 777-83, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11706305

ABSTRACT

Liver support systems based on either dialysis, filtration, and adsorption or plasmaperfusion over hepatocytes have been tested clinically with varying success. A new approach in this field is the selective removal of albumin-bound end products of metabolism. This can be achieved in a high-flux dialysis setting by the addition of human serum albumin as a molecular adsorbent to the dialysate with subsequent recirculation of the dialysate over sorbents (molecular adsorbent recirculating system). The current knowledge about the albumin dialysis molecular adsorbent recirculating system is reviewed in this article.


Subject(s)
Albumins/administration & dosage , Renal Dialysis/methods , Adsorption , Cost-Benefit Analysis , Humans , Renal Dialysis/economics , Renal Dialysis/mortality , Survival Rate
5.
J Am Soc Nephrol ; 12 Suppl 17: S75-82, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11251037

ABSTRACT

Liver failure resulting from different causes and its concomitant complications represent difficult-to-treat conditions with high mortality rates, despite improved therapeutic modalities in intensive care medicine. The accumulation of albumin-bound metabolites that are normally cleared by the liver, such as bilirubin and bile acids, contributes substantially to the development of multiorgan dysfunction in these clinical situations. The molecular adsorbent recirculating system (MARS) represents a cell-free, extracorporeal, liver assistance method for the selective removal of albumin-bound substances. Moreover, it enables the removal of excess water and water-soluble substances via an inbuilt dialysis step. Since 1993, >400 patients have been treated in 53 centers in Europe, the United States, and Asia. Diseases treated with MARS included acute exacerbation of chronic hepatic failure, hepatorenal syndrome, acute hepatic failure, and primary nonfunction/poor function after liver transplantation and major liver resection. Treatments were well tolerated. No severe adverse events were observed. Six- to 8-h MARS treatments resulted in significant (P < 0.05) removal of bilirubin, bile acids, tryptophan, short- and middle-chain fatty acids, aromatic amino acids, and ammonia. Clearance rates for strongly albumin-bound substances were between 10 and 60 ml/min. The removal of albumin-bound toxins resulted in decreases in hepatic encephalopathy, increases in mean arterial pressure, and improvements in kidney and liver function. In the first randomized clinical trial of the MARS method for treatment of the hepatorenal syndrome, significant prolongation of survival was observed for the MARS-treated group. It is concluded that the MARS method can contribute to the treatment of critically ill patients with liver failure and different underlying diseases.


Subject(s)
Critical Illness/therapy , Liver Failure/therapy , Sorption Detoxification/methods , Humans , Liver Failure/physiopathology
8.
Ther Apher ; 5(5): 417-22, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11778928

ABSTRACT

Recently, significant improvement of renal function and prolongation of survival were reported in hepatorenal syndrome (HRS) patients treated with the Molecular Adsorbent Recirculating System (MARS). As no impact on extrarenal organ function was documented, this trial looked into multiple organ function changes during MARS in HRS patients. Eight HRS patients (4 male, mean age 42.1 years, range 30-58, all United Network for Organ Sharing [UNOS] status 2A) were treated intermittendly 4-14 times (total 47, mean 5.9 +/- 3.4) between 4 and 8 h/single treatment. The following changes were observed pre- and posttreatment: bilirubin 466 +/- 146 to 284 +/- 134 micromol/L, creatinine 380 +/- 182 to 163 +/- 119 micromol/L, urea 26.4 +/- 10.3 to 12.9 +/- 4.9 mmol/L, plasma sodium 127.5 +/- 7.7 to 137.5 +/- 4.8 mmol/L (all p < 0.01). Mean arterial pressure (MAP) increased from 71.9 +/- 12.8 to 95.6 +/- 7.8 Torr (p < 0.001). Oliguria or anuria, present in all patients, was successfully reverted. Ascites, present in all patients, was not detectable after the treatment period. The hepatic encephalopathy grade decreased from 2.8 +/- 0.8 to 0.8 +/- 0.7 (p < 0.0001). Child-Index decreased from 13.25 +/- 1.3 to 9.4 +/- 1.8 (p < 0.001). The hospital survival rate was 62%. One man underwent successful liver transplantation 18 months after the treatment. We conclude that MARS can improve multiple organ functions in patients with HRS.


Subject(s)
Albumins/therapeutic use , Hepatorenal Syndrome/blood , Hepatorenal Syndrome/therapy , Multiple Organ Failure/blood , Multiple Organ Failure/therapy , Renal Dialysis/methods , Adult , Chronic Disease , Extracorporeal Circulation/methods , Female , Hemodialysis Solutions/therapeutic use , Humans , Liver Diseases, Alcoholic/blood , Liver Diseases, Alcoholic/complications , Liver Diseases, Alcoholic/therapy , Liver Failure, Acute/blood , Liver Failure, Acute/therapy , Male , Middle Aged
9.
Liver Transpl ; 6(5): 603-13, 2000 Sep.
Article in English | MEDLINE | ID: mdl-10980060

ABSTRACT

Liver failure associated with excretory insufficiency and jaundice results in an endogenous accumulation of toxins involved in the impairment of cardiovascular, kidney, and cerebral function. Moreover, these toxins have been shown to damage the liver itself by inducing hepatocellular apoptosis and necrosis, thus creating a vicious cycle of the disease. We report a retrospective cohort study of 26 patients with acute or chronic liver failure with intrahepatic cholestasis (bilirubin level > 20 mg/dL) who underwent a new extracorporeal blood purification treatment. A synthetic hydrophilic/hydrophobic domain-presenting semipermeable membrane (pore size < albumin size, 100-nm thick) was used for extracorporeal blood detoxification using dialysis equipment. The opposite side was rinsed with ligandin-like proteins as molecular adsorbents that were regenerated online using a chromatography-like recycling system (molecular adsorbent recirculating system [MARS]). Bile acid and bilirubin levels, representing the previously described toxins, were reduced by 16% to 53% and 10% to 90% of the initial concentration by a single treatment of 6 to 8 hours, respectively. Toxicity testing of patient plasma onto primary rat hepatocytes by live/dead fluorescence microscopy showed cell-damaging effects of jaundiced plasma that were not observed after treatment. Patients with a worsening of Child-Turcotte-Pugh (CTP) index before the treatments showed a significant improvement of this index during a period of 2 to 14 single treatments with an average of 14 days. After withdrawal of MARS treatment, this improvement was sustained in all long-term survivors. Ten patients represented a clinical status equivalent to the United Network for Organ Sharing (UNOS) status 2b (group A1), and all survived. Sixteen patients represented a clinical status equivalent to UNOS status 2a, and 7 of these patients survived (group A2), whereas 9 patients (group B) died. We conclude that in acute excretory failure caused by a chronic liver disease, this treatment provides a therapy option to remove toxins involved in multiorgan dysfunction secondary to liver failure.


Subject(s)
Extracorporeal Circulation , Inactivation, Metabolic , Liver Failure/metabolism , Liver/metabolism , Renal Dialysis , Toxins, Biological/blood , Adult , Female , Humans , Liver Failure/blood , Male , Middle Aged , Retrospective Studies , Treatment Outcome
10.
Liver Transpl ; 6(3): 277-86, 2000 May.
Article in English | MEDLINE | ID: mdl-10827226

ABSTRACT

In hepatorenal syndrome (HRS), renal insufficiency is often progressive, and the prognosis is extremely poor under standard medical therapy. The molecular adsorbent recirculating system (MARS) is a modified dialysis method using an albumin-containing dialysate that is recirculated and perfused online through charcoal and anion-exchanger columns. MARS enables the selective removal of albumin-bound substances. A prospective controlled trial was performed to determine the effect of MARS treatment on 30-day survival in patients with type I HRS at high risk (bilirubin level, > or =15 mg/dL) compared with standard treatment. Thirteen patients with cirrhosis with type I HRS were included from 1997 to 1999. All were Child's class C, with Child-Turcotte-Pugh scores of 12.4 +/- 1. 0, United Network for Organ Sharing status 2A, and total bilirubin values of 25.7 +/- 14.0 mg/dL. Eight patients were treated with the MARS method in addition to hemodiafiltration (HDF) and standard medical therapy, and 5 patients were in the control group (HDF and standard medical treatment alone). None of these patients underwent liver transplantation or received a transjugular intrahepatic portosystemic shunt or vasopressin analogues during the observation period. In the MARS group, 5.2 +/- 3.6 treatments (range, 1 to 10 treatments) were performed for 6 to 8 hours daily per patient. A significant decrease in bilirubin and creatinine levels (P <.01) and increase in serum sodium level and prothrombin activity (P <.01) were observed in the MARS group. Mortality rates were 100% in the control group at day 7 and 62.5% in the MARS group at day 7 and 75% at day 30, respectively (P <.01). We conclude that the removal of albumin-bound substances with the MARS method can contribute to the treatment of type I HRS.


Subject(s)
Albumins , Dialysis Solutions , Hepatorenal Syndrome/therapy , Renal Dialysis/methods , Hepatorenal Syndrome/mortality , Humans , Liver Cirrhosis/complications , Prospective Studies , Survival Rate , Treatment Outcome
11.
Artif Organs ; 23(4): 319-30, 1999 Apr.
Article in English | MEDLINE | ID: mdl-10226696

ABSTRACT

The use of xenogenic or genetically engineered cell types in bioartificial liver support systems requires separation methods between the patients' blood and the liver support bioreactors that guarantee the sufficient transfer of pathophysiologically relevant substances but prevent complications. The present paper describes a new membrane separation system that is nearly impermeable to proteins but enables the exchange of water soluble and protein bound toxins by a special membrane and a recycled protein containing dialysate. Because the full range of toxins in hepatic failure has still not been identified, the value of this membrane separation method was evaluated clinically. Thirteen patients suffering from life threatening hepatic failure who had not responded to state of the art therapy were treated with this device, the molecular adsorbent recycling system (MARS). The overall survival rate was 69%. All patients showed positive response to the therapy, indicating that the presented membrane separator combines therapeutic effectivity with the highest safety criteria for the patient by cutting the exchange of substances below the level of proteins.


Subject(s)
Liver Failure/therapy , Liver, Artificial , Renal Dialysis/methods , Adsorption , Adult , Ammonia/blood , Bilirubin/blood , Cholinesterases/blood , Creatinine/blood , Female , Hepatic Encephalopathy/blood , Hepatic Encephalopathy/mortality , Hepatic Encephalopathy/therapy , Humans , Liver Failure/blood , Liver Failure/mortality , Male , Membranes, Artificial , Middle Aged , Protein Binding , Serum Albumin/metabolism , Survival Rate , Urea/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...