1.
Surg Endosc ; 35(4): 1610-1617, 2021 04.
Article in English | MEDLINE | ID: mdl-32253555

ABSTRACT

BACKGROUND: Minimally invasive endopancreatic surgery (EPS), performing a pancreatic resection from inside the pancreatic duct, has been proposed as an experimental alternative to duodenum-preserving pancreatic head resection in benign diseases such as chronic pancreatitis, but is complicated by difficult spatial orientation when trying to reach structures of interest. This study assessed the feasibility and potential benefits of image-guided EPS using a computer-assisted navigation system in artificial pancreas silicon model. METHODS: A surgical navigation system displayed a 3D reconstruction of the original computed tomography (CT) scan and the endoscope in relation to a selected target structure. In a first step, different surface landmark (LM)-based and intraparenchymal LM-based approaches for image-to-physical space registration were evaluated. The accuracy of registration was measured as fiducial registration error (FRE). Subsequently, intrapancreatic lesions (n = 8) that were visible on preoperative imaging, but not on the endoscopic view, were targeted with a computer-assisted, image-guided endopancreatic resection technique in pancreas silicon models. After each experiment, a CT scan was obtained for measurement of the shortest distance from the resection cavity to the centre of the lesion. RESULTS: Intraparenchymal LM registration [FRE 2.24 mm (1.40-2.85)] was more accurate than surface LM registration [FRE 3.46 mm (2.25-4.85); p = 0.035], but not more accurate than combined registration of intraparenchymal and surface LM [FRE 2.46 mm (1.60-3.35); p = 0.052]. Using image-guided EPS, six of seven lesions were successfully targeted. The median distance from the resection cavity to the centre of the lesion on CT was 1.52 mm (0-2.4). In one pancreas, a lesion could not be resected due to the fragility of the pancreas model. CONCLUSION: Image-guided minimally invasive EPS using a computer-assisted navigation system enabled successful targeting of pancreatic lesions that were invisible on the endoscopic image, but detectable on preoperative imaging. In the clinical setting, this tool could facilitate complex minimally invasive and robotic pancreatic procedures.


Subject(s)
Endoscopy/methods , Image Processing, Computer-Assisted/methods , Minimally Invasive Surgical Procedures/methods , Pancreatectomy/methods , Surgery, Computer-Assisted/methods , Female , Humans , Male
2.
IEEE Open J Eng Med Biol ; 1: 166-173, 2020.
Article in English | MEDLINE | ID: mdl-35402946

ABSTRACT

Training of surgical residents and the establishment of innovative surgical techniques require training phantoms that realistically mimic human anatomy. Because animal models have their limitations due to ethical aspects, costs, and the required efforts to set up such training, artificial phantoms are a promising alternative. In the field of image-guided surgery, the challenge lies in developing phantoms that are accurate both anatomically and in terms of imaging properties, while taking the cost factor into account. With respect to the pancreas, animal models are less suitable because their anatomy differs significantly from human anatomy and tissue properties rapidly degrade in the case of ex vivo models. Nevertheless, progress with artificial phantoms has been sparse, although the need for innovative, minimally invasive therapies that require adequate training is steadily increasing. Methods: In the course of this project, an artificial pancreas phantom that is compatible with basic electrosurgical techniques was developed with realistic anatomic and haptic properties, computed tomography, and ultrasound imaging capabilities. This article contains step-by-step instructions for the fabrication of a low-cost pancreatic phantom. The molds are also available for download in a 3D file format. Results: The phantom was successfully validated with regard to its computed tomography and ultrasound properties. As a result, the phantom could be used in combination with a state-of-the-art computer-assisted navigation system. The resection capabilities were positively evaluated in a preclinical study evaluating endoscopic resections using the navigation system. Finally, the durability of the phantom material was tested in a study with multiple needle insertions. Conclusion: The developed phantom represents an open-access and low-cost durable alternative to conventional animal models in the continuous process of surgical training and development of new techniques.

3.
J Gastrointest Surg ; 24(10): 2251-2258, 2020 10.
Article in English | MEDLINE | ID: mdl-31621024

ABSTRACT

BACKGROUND: To investigate efficiency, accuracy and clinical benefit of a new augmented reality system for 3D laparoscopic liver surgery. METHODS: All patients who received laparoscopic liver resection by a new image-guided surgery system with augmented 3D-imaging in a university hospital were included for analysis. Digitally processed preoperative cross-sectional imaging was merged with the laparoscopic image. Intraoperative efficiency of the procedure was measured as time needed to achieve sufficient registration accuracy. Technical accuracy was reported as fiducial registration error (FRE). Clinical benefit was assessed trough a questionnaire, reporting measures in a 5-point Likert scale format ranging from 1 (high) to 5 (low). RESULTS: From January to March 2018, ten laparoscopic liver resections of a total of 18 lesions were performed using the novel augmented reality system. Median time for registration was 8:50 min (range 1:31-23:56). The mean FRE was reduced from 14.0 mm (SD 5.0) in the first registration attempt to 9.2 mm (SD 2.8) in the last attempt. The questionnaire revealed the ease of use of the system (1.2, SD 0.4) and the benefit for resection of vanishing lesions (1.0, SD 0.0) as convincing positive aspects, whereas image registration accuracy for resection guidance was consistently judged as too inaccurate. CONCLUSIONS: Augmented reality in 3D laparoscopic liver surgery with landmark-based registration technique is feasible with only little impact on the intraoperative workflow. The benefit for detecting particularly vanishing lesions is high. For an additional benefit during the resection process, registration accuracy has to be improved and non-rigid registration algorithms will be required to address intraoperative anatomical deformation.


Subject(s)
Laparoscopy , Surgery, Computer-Assisted , Algorithms , Hepatectomy , Humans , Imaging, Three-Dimensional , Liver/diagnostic imaging , Liver/surgery
4.
Liver Int ; 39(10): 1975-1985, 2019 10.
Article in English | MEDLINE | ID: mdl-31276296

ABSTRACT

BACKGROUND & AIMS: Ablation plays an important role in the treatment of hepatocellular carcinoma. Because image-guided navigation technology has recently entered the clinical setting, we aimed to analyse its safety, therapeutic and procedural efficiency. METHODS: Retrospective analysis of patients treated with stereotactic image-guided microwave ablation (SMWA) between January 2015 and December 2017. Interventions were performed using computertomography-guidance with needle trajectory, ablation planning and automatic single-marker patient registration. Needle placement and ablation coverage was controlled by image fusion under general anaesthesia with jet-ventilation. RESULTS: In total 174 ablations were performed in 88 patients during 119 interventions. Mean age was 66 (46-84) years, 74 (84.1%) were men and 74% were Child Pugh Class A. Median tumour size was 16 (4-45) mm, 62.2% were BCLC A. Median lateral and longitudinal error of needle placement were 3.2 (0.2-14.1) and 1.6 (0-15.8) mm. Median one tumour (1-4) was ablated per session. One patient developed a Dindo IIIb (0.8%) complication, six minor complications. After re-ablation of 12 lesions, an efficacy rate of 96.3% was achieved. Local tumour progression was 6.3% (11/174). Close proximity to major vessels was significantly correlated with local tumour progression (P < .05). Median overall follow-up was 17.5 months after intervention and 24 months after initial diagnosis. BCLC stage, child class and previous treatment were significantly correlated with overall survival (P < .05). CONCLUSION: Stereotactic image-guided microwave ablation is a safe and efficient treatment for HCC offering a curative treatment approach in general and in particular for lesions not detectable on conventional imaging or untreatable because of difficult anatomic locations.


Subject(s)
Carcinoma, Hepatocellular/surgery , Catheter Ablation/methods , Liver Neoplasms/surgery , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/mortality , Female , Hepatectomy/methods , High-Frequency Jet Ventilation/methods , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/mortality , Male , Microwaves/therapeutic use , Middle Aged , Patient Safety , Retrospective Studies , Stereotaxic Techniques , Survival Analysis , Switzerland , Treatment Outcome
5.
Surg Endosc ; 31(4): 1982-1985, 2017 04.
Article in English | MEDLINE | ID: mdl-27572065

ABSTRACT

BACKGROUND: Palliative irreversible electroporation of pancreatic adenocarcinomas is rapidly gaining in interest since a large proportion of these patients cannot be radically resected. METHODS: This is a description of a minimally invasive approach to irreversible electroporation of pancreatic tumors using computer-assisted navigation, laparoscopy and laparoscopic ultrasound to correctly guide electrodes into the tissue. RESULTS: The procedure is presented. CONCLUSION: Minimally invasive irreversible electroporation of pancreatic tumors through computer-assisted navigation of needles during laparoscopy is a feasible and accurate approach.


Subject(s)
Adenocarcinoma/surgery , Electroporation/methods , Pancreatic Neoplasms/surgery , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/pathology , Aged , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Needles , Palliative Care , Pancreas/diagnostic imaging , Pancreas/surgery , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Tomography, X-Ray Computed , Ultrasonography
7.
Acta Neurochir (Wien) ; 158(9): 1711-20, 2016 09.
Article in English | MEDLINE | ID: mdl-27416860

ABSTRACT

BACKGROUND: Treatment of complex intracranial aneurysms requires strategic pre-interventional or preoperative planning. In addition to modern three-dimensional (3D) rotational angiography, computed tomography angiography (CTA) or magnetic resonance angiogram (MRA), a solid, tangible 3D model may improve anatomical comprehension and treatment planning. A 3D rapid prototyping (RP) technique based on multimodal imaging data was evaluated for use in planning of treatment for complex aneurysmal configurations. METHODS: Six patients with complex aneurysms were selected for 3D RP based on CTA and 3D rotational angiography data. Images were segmented using image-processing software to create virtual 3D models. Three-dimensional rapid prototyping techniques transformed the imaging data into physical 3D models, which were used and evaluated for interdisciplinary treatment planning. RESULTS: In all cases, the model provided a comprehensive 3D representation of relevant anatomical structures and improved understanding of related vessels. Based on the 3D model, primary bypass surgery with subsequent reconstruction of the aneurysm was then considered advantageous in all but one patient after simulation of multiple approaches. CONCLUSIONS: Preoperative prediction of intraoperative anatomy using the 3D model was considered helpful for treatment planning. The use of 3D rapid prototyping may enhance understanding of complex configurations in selected large or giant aneurysms, especially those pretreated with clips or coils.


Subject(s)
Cerebral Angiography/methods , Embolization, Therapeutic/methods , Image Processing, Computer-Assisted/methods , Intracranial Aneurysm/surgery , Patient-Specific Modeling , Adult , Embolization, Therapeutic/adverse effects , Female , Humans , Intracranial Aneurysm/diagnostic imaging , Male , Middle Aged
8.
Langenbecks Arch Surg ; 401(4): 495-502, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27122364

ABSTRACT

BACKGROUND: Image-guided systems have recently been introduced for their application in liver surgery. We aimed to identify and propose suitable indications for image-guided navigation systems in the domain of open oncologic liver surgery and, more specifically, in the setting of liver resection with and without microwave ablation. METHOD: Retrospective analysis was conducted in patients undergoing liver resection with and without microwave ablation using an intraoperative image-guided stereotactic system during three stages of technological development (accuracy: 8.4 ± 4.4 mm in phase I and 8.4 ± 6.5 mm in phase II versus 4.5 ± 3.6 mm in phase III). It was evaluated, in which indications image-guided surgery was used according to the different stages of technical development. RESULTS: Between 2009 and 2013, 65 patients underwent image-guided surgical treatment, resection alone (n = 38), ablation alone (n = 11), or a combination thereof (n = 16). With increasing accuracy of the system, image guidance was progressively used for atypical resections and combined microwave ablation and resection instead of formal liver resection (p < 0.0001). CONCLUSION: Clinical application of image guidance is feasible, while its efficacy is subject to accuracy. The concept of image guidance has been shown to be increasingly efficient for selected indications in liver surgery. While accuracy of available technology is increasing pertaining to technological advancements, more and more previously untreatable scenarios such as multiple small, bilobar lesions and so-called vanishing lesions come within reach.


Subject(s)
Hepatectomy , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Surgery, Computer-Assisted , Aged , Female , Humans , Imaging, Three-Dimensional , Liver Neoplasms/pathology , Male , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed , Ultrasonography
9.
Int J Comput Assist Radiol Surg ; 11(8): 1499-513, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26476640

ABSTRACT

PURPOSE: Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS: In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS: Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS: We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.


Subject(s)
Laparoscopy/methods , Lasers , Liver/surgery , Surgery, Computer-Assisted/methods , Humans , Laparoscopy/instrumentation , Liver/diagnostic imaging , Motion , Phantoms, Imaging , Surgery, Computer-Assisted/instrumentation
10.
World J Gastroenterol ; 20(40): 14992-6, 2014 Oct 28.
Article in English | MEDLINE | ID: mdl-25356061

ABSTRACT

For patients with extensive bilobar colorectal liver metastases (CRLM), initial surgery may not be feasible and a multimodal approach including microwave ablation (MWA) provides the only chance for prolonged survival. Intraoperative navigation systems may improve the accuracy of ablation and surgical resection of so-called "vanishing lesions", ultimately improving patient outcome. Clinical application of intraoperative navigated liver surgery is illustrated in a patient undergoing combined resection/MWA for multiple, synchronous, bilobar CRLM. Regular follow-up with computed tomography (CT) allowed for temporal development of the ablation zones. Of the ten lesions detected in a preoperative CT scan, the largest lesion was resected and the others were ablated using an intraoperative navigation system. Twelve months post-surgery a new lesion (Seg IVa) was detected and treated by trans-arterial embolization. Nineteen months post-surgery new liver and lung metastases were detected and a palliative chemotherapy started. The patient passed away four years after initial diagnosis. For patients with extensive CRLM not treatable by standard surgery, navigated MWA/resection may provide excellent tumor control, improving longer-term survival. Intraoperative navigation systems provide precise, real-time information to the surgeon, aiding the decision-making process and substantially improving the accuracy of both ablation and resection. Regular follow-ups including 3D modeling allow for early discrimination between ablation zones and recurrent tumor lesions.


Subject(s)
Ablation Techniques/methods , Colorectal Neoplasms/pathology , Hepatectomy/methods , Liver Neoplasms/secondary , Liver Neoplasms/surgery , Microwaves/therapeutic use , Surgery, Computer-Assisted/methods , Disease Progression , Fatal Outcome , Humans , Liver Neoplasms/diagnostic imaging , Middle Aged , Palliative Care , Predictive Value of Tests , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
11.
J Surg Res ; 184(2): 825-31, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23684617

ABSTRACT

BACKGROUND: Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS: Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS: Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS: The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.


Subject(s)
Carcinoma, Hepatocellular/surgery , Imaging, Three-Dimensional/methods , Liver Neoplasms/surgery , Robotics , Surgery, Computer-Assisted/methods , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/etiology , Endoscopy , Female , Humans , Liver/surgery , Liver Cirrhosis/complications , Liver Neoplasms/etiology , Male , Minimally Invasive Surgical Procedures , Pilot Projects , Stereotaxic Techniques , Surgery, Computer-Assisted/instrumentation , Treatment Outcome
12.
Crit Rev Biomed Eng ; 40(3): 199-220, 2012.
Article in English | MEDLINE | ID: mdl-22694200

ABSTRACT

Oncological liver surgery and interventions aim for removal of tumor tissue while preserving a sufficient amount of functional tissue to ensure organ regeneration. This requires detailed understanding of the patient-specific internal organ anatomy (blood vessel system, bile ducts, tumor location). The introduction of computer support in the surgical process enhances anatomical orientation through patient-specific 3D visualization and enables precise reproduction of planned surgical strategies though stereotactic navigation technology. This article provides clinical background information on indications and techniques for the treatment of liver tumors, reviews the technological contributions addressing the problem of organ motion during navigated surgery on a deforming organ, and finally presents an overview of the clinical experience in computer-assisted liver surgery and interventions. The review concludes that several clinically applicable solutions for computer aided liver surgery are available and small-scale clinical trials have been performed. Further developments will be required more accurate and faster handling of organ deformation and large clinical studies will be required for demonstrating the benefits of computer aided liver surgery.


Subject(s)
Imaging, Three-Dimensional/methods , Liver Neoplasms/surgery , Liver/surgery , Surgery, Computer-Assisted/methods , Computer Simulation , Humans , Liver/anatomy & histology , Motion , Respiration
13.
Comput Aided Surg ; 16(5): 203-19, 2011.
Article in English | MEDLINE | ID: mdl-21787176

ABSTRACT

Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Bone and Bones , Positron-Emission Tomography/instrumentation , Tomography, X-Ray/instrumentation , Angioplasty, Balloon, Coronary/methods , Cadaver , Diagnosis, Computer-Assisted , Equipment Failure Analysis , Feasibility Studies , Humans , Radiotherapy, Computer-Assisted/instrumentation , Workflow
14.
IEEE Trans Biomed Eng ; 58(6): 1855-64, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21411401

ABSTRACT

Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system's position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device's projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.


Subject(s)
Digestive System Surgical Procedures/instrumentation , Image Processing, Computer-Assisted/instrumentation , Liver/surgery , Surgery, Computer-Assisted/instrumentation , Animals , Equipment Design , Feasibility Studies , Humans , Swine , User-Computer Interface
15.
Z Med Phys ; 21(2): 113-23, 2011 May.
Article in English | MEDLINE | ID: mdl-21247744

ABSTRACT

This article presents the implementation and validation of a dose calculation approach for deforming anatomical objects. Deformation is represented by deformation vector fields leading to deformed voxel grids representing the different deformation scenarios. Particle transport in the resulting deformed voxels is handled through the approximation of voxel surfaces by triangles in the geometry implementation of the Swiss Monte Carlo Plan framework. The focus lies on the validation methodology which uses computational phantoms representing the same physical object through regular and irregular voxel grids. These phantoms are chosen such that the new implementation for a deformed voxel grid can be compared directly with an established dose calculation algorithm for regular grids. Furthermore, separate validation of the aspects voxel geometry and the density changes resulting from deformation is achieved through suitable design of the validation phantom. We show that equivalent results are obtained with the proposed method and that no statistically significant errors are introduced through the implementation for irregular voxel geometries. This enables the use of the presented and validated implementation for further investigations of dose calculation on deforming anatomy.


Subject(s)
Algorithms , Monte Carlo Method , Neoplasms/radiotherapy , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Humans , Physics , Radiotherapy Setup Errors/statistics & numerical data
16.
IEEE Trans Biomed Eng ; 58(3): 531-40, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20693105

ABSTRACT

This paper presents methods based on information filters for solving matching problems with emphasis on real time, or effectively real-time applications. Both applications discussed in this paper deal with ultrasound-based rigid registration in computer-assisted orthopedic surgery. In the first application, the usual workflow of rigid registration is reformulated such that registration algorithms would iterate while the surgeon is acquiring ultrasound images of the anatomy to be operated. Using this effectively real-time approach to registration, the surgeon would then receive feedback in order to better gauge the quality of the final registration outcome. The second application considered in this paper circumvents the need to attach physical markers to bones for anatomical referencing. Experiments using anatomical objects immersed in water are performed in order to evaluate and compare the different methods presented herein, using both 2-D as well as real-time 3-D ultrasound.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Orthopedics/methods , Signal Processing, Computer-Assisted , Surgery, Computer-Assisted/methods , Ultrasonography/methods , Analysis of Variance , Fiducial Markers , Humans , Tomography, X-Ray Computed
17.
Article in English | MEDLINE | ID: mdl-21096767

ABSTRACT

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporeal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.


Subject(s)
Image Processing, Computer-Assisted/methods , Nephrostomy, Percutaneous/instrumentation , Surgery, Computer-Assisted/instrumentation , Equipment Design , Fiducial Markers , Humans , Models, Anatomic , Nephrostomy, Percutaneous/methods , Phantoms, Imaging , Reproducibility of Results , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed
18.
Article in English | MEDLINE | ID: mdl-21096125

ABSTRACT

Navigated ultrasound (US) imaging is used for the intra-operative acquisition of 3D image data during image-guided surgery. The presented approach includes the design of a compact and easy to use US calibration device and its integration into a software application for navigated liver surgery. User interaction during the calibration process is minimized through automatic detection of the calibration process followed by automatic image segmentation, calculation of the calibration transform and validation of the obtained result. This leads to a fast, interaction-free and fully automatic calibration procedure enabling intra-operative US calibration being performed by the surgical user.


Subject(s)
Hepatectomy/instrumentation , Hepatectomy/standards , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/standards , Ultrasonography, Interventional/instrumentation , Ultrasonography, Interventional/standards , Calibration/standards , Equipment Design , Equipment Failure Analysis , Humans , Reproducibility of Results , Sensitivity and Specificity , Surgery, Computer-Assisted/methods , Switzerland , Transducers