Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 219
Filter
1.
Data Brief ; 50: 109513, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37663773

ABSTRACT

Population-averaged brain atlases, that are represented in a standard space with anatomical labels, are instrumental tools in neurosurgical planning and the study of neurodegenerative conditions. Traditional brain atlases are primarily derived from anatomical scans and contain limited information regarding the axonal organization of the white matter. With the advance of diffusion MRI that allows the modeling of fiber orientation distribution (FOD) in the brain tissue, there is an increasing interest for a population-averaged FOD template, especially based on a large healthy aging cohort, to offer structural connectivity information for connectomic surgery and analysis of neurodegeneration. The dataset described in this article contains a set of multi-contrast structural connectomic MRI atlases, including T1w, T2w, and FOD templates, along with the associated whole brain tractograms. The templates were made using multi-contrast group-wise registration based on 3T MRIs of 422 Human Connectome Project in Aging (HCP-A) subjects. To enhance the usability, probabilistic tissue maps and segmentation of 22 subcortical structures are provided. Finally, the subthalamic nucleus shown in the atlas is parcellated into sensorimotor, limbic, and associative sub-regions based on their structural connectivity to facilitate the analysis and planning of deep brain stimulation procedures. The dataset is available on the OSF Repository: https://osf.io/p7syt.

2.
J Neurosci Methods ; 397: 109948, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37572883

ABSTRACT

BACKGROUND: Accurate targeting of brain structures for in-vivo electrophysiological recordings is essential for basic as well as clinical neuroscience research. Although methodologies for precise targeting and recording from the cortical surface are abundant, such protocols are scarce for deep brain structures. NEW METHOD: We have incorporated stable fiducial markers within a custom cranial cap for improved image-guided neuronavigation targeting of subcortical structures in macaque monkeys. Anchor bolt chambers allowed for a minimally invasive entrance into the brain for chronic recordings. A 3D-printed microdrive allowed for semi-chronic applications. RESULTS: We achieved an average Euclidean targeting error of 1.6 mm and a radial error of 1.2 mm over three implantations in two animals. Chronic and semi-chronic implantations allowed for recording of extracellular neuronal activity, with single-neuron activity examples shown from one macaque monkey. COMPARISON WITH EXISTING METHOD(S): Traditional stereotactic methods ignore individual anatomical variability. Our targeting approach allows for a flexible, subject-specific surgical plan with targeting errors lower than what is reported in humans, and equal to or lower than animal models using similar methods. Utilizing an anchor bolt as a chamber reduced the craniotomy size needed for electrode implantation, compared to conventional large access chambers which are prone to infection. Installation of an in-house, 3D-printed, screw-to-mount mechanical microdrive is in contrast to existing semi-chronic methods requiring fabrication, assembly, and installation of complex parts. CONCLUSIONS: Leveraging commercially available tools for implantation, our protocol decreases the risk of infection from open craniotomies, and improves the accuracy of chronic electrode implantations targeting deep brain structures in large animal models.


Subject(s)
Brain , Neuronavigation , Humans , Animals , Neuronavigation/methods , Microelectrodes , Stereotaxic Techniques , Craniotomy , Electrodes, Implanted
3.
Int J Comput Assist Radiol Surg ; 18(7): 1225-1233, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37222930

ABSTRACT

PURPOSE: Existing field generators (FGs) for magnetic tracking cause severe image artifacts in X-ray images. While FG with radio-lucent components significantly reduces these imaging artifacts, traces of coils and electronic components may still be visible to trained professionals. In the context of X-ray-guided interventions using magnetic tracking, we introduce a learning-based approach to further reduce traces of field-generator components from X-ray images to improve visualization and image guidance. METHODS: An adversarial decomposition network was trained to separate the residual FG components (including fiducial points introduced for pose estimation), from the X-ray images. The main novelty of our approach lies in the proposed data synthesis method, which combines existing 2D patient chest X-ray and FG X-ray images to generate 20,000 synthetic images, along with ground truth (images without the FG) to effectively train the network. RESULTS: For 30 real images of a torso phantom, our enhanced X-ray image after image decomposition obtained an average local PSNR of 35.04 and local SSIM of 0.97, whereas the unenhanced X-ray images averaged a local PSNR of 31.16 and local SSIM of 0.96. CONCLUSION: In this study, we proposed an X-ray image decomposition method to enhance X-ray image for magnetic navigation by removing FG-induced artifacts, using a generative adversarial network. Experiments on both synthetic and real phantom data demonstrated the efficacy of our method.


Subject(s)
Artifacts , Image Processing, Computer-Assisted , Humans , Image Processing, Computer-Assisted/methods , X-Rays , Radiography , Phantoms, Imaging
4.
Int J Comput Assist Radiol Surg ; 18(7): 1159-1166, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37162735

ABSTRACT

PURPOSE: US-guided percutaneous focal liver tumor ablations have been considered promising curative treatment techniques. To address cases with invisible or poorly visible tumors, registration of 3D US with CT or MRI is a critical step. By taking advantage of deep learning techniques to efficiently detect representative features in both modalities, we aim to develop a 3D US-CT/MRI registration approach for liver tumor ablations. METHODS: Facilitated by our nnUNet-based 3D US vessel segmentation approach, we propose a coarse-to-fine 3D US-CT/MRI image registration pipeline based on the liver vessel surface and centerlines. Then, phantom, healthy volunteer and patient studies are performed to demonstrate the effectiveness of our proposed registration approach. RESULTS: Our nnUNet-based vessel segmentation model achieved a Dice score of 0.69. In healthy volunteer study, 11 out of 12 3D US-MRI image pairs were successfully registered with an overall centerline distance of 4.03±2.68 mm. Two patient cases achieved target registration errors (TRE) of 4.16 mm and 5.22 mm. CONCLUSION: We proposed a coarse-to-fine 3D US-CT/MRI registration pipeline based on nnUNet vessel segmentation models. Experiments based on healthy volunteers and patient trials demonstrated the effectiveness of our registration workflow. Our code and example data are publicly available in this r epository.


Subject(s)
Liver Neoplasms , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Liver Neoplasms/pathology , Imaging, Three-Dimensional/methods , Image Processing, Computer-Assisted/methods
5.
Phys Med Biol ; 68(8)2023 04 05.
Article in English | MEDLINE | ID: mdl-36893468

ABSTRACT

Objective. The treatment of glioblastoma (GBM) using low intensity electric fields (∼1 V cm-1) is being investigated using multiple implanted bioelectrodes, which was termed intratumoral modulation therapy (IMT). Previous IMT studies theoretically optimized treatment parameters to maximize coverage with rotating fields, which required experimental investigation. In this study, we employed computer simulations to generate spatiotemporally dynamic electric fields, designed and purpose-built an IMT device forin vitroexperiments, and evaluated the human GBM cellular responses to these fields.Approach. After measuring the electrical conductivity of thein vitroculturing medium, we designed experiments to evaluate the efficacy of various spatiotemporally dynamic fields: (a) different rotating field magnitudes, (b) rotating versus non-rotating fields, (c) 200 kHz versus 10 kHz stimulation, and (d) constructive versus destructive interference. A custom printed circuit board (PCB) was fabricated to enable four-electrode IMT in a 24-well plate. Patient derived GBM cells were treated and analyzed for viability using bioluminescence imaging.Main results. The optimal PCB design had electrodes placed 6.3 mm from the center. Spatiotemporally dynamic IMT fields at magnitudes of 1, 1.5, and 2 V cm-1reduced GBM cell viability to 58%, 37% and 2% of sham controls respectively. Rotating versus non-rotating, and 200 kHz versus 10 kHz fields showed no statistical difference. The rotating configuration yielded a significant reduction (p< 0.01) in cell viability (47 ± 4%) compared to the voltage matched (99 ± 2%) and power matched (66 ± 3%) destructive interference cases.Significance. We found the most important factors in GBM cell susceptibility to IMT are electric field strength and homogeneity. Spatiotemporally dynamic electric fields have been evaluated in this study, where improvements to electric field coverage with lower power consumption and minimal field cancellations has been demonstrated. The impact of this optimized paradigm on cell susceptibility justifies its future use in preclinical and clinical trial investigations.


Subject(s)
Brain Neoplasms , Electric Stimulation Therapy , Glioblastoma , Humans , Electric Stimulation Therapy/methods , Brain Neoplasms/therapy , Glioblastoma/radiotherapy , Electric Conductivity
6.
Neuroimage Clin ; 36: 103201, 2022.
Article in English | MEDLINE | ID: mdl-36126518

ABSTRACT

This study aimed to evaluate the use of diffusion kurtosis imaging (DKI) to detect microstructural abnormalities within the temporal pole (TP) and its temporopolar cortex in temporal lobe epilepsy (TLE) patients. DKI quantitative maps were obtained from fourteen lesional TLE and ten non-lesional TLE patients, along with twenty-three healthy controls. Data collected included mean (MK); radial (RK) and axial kurtosis (AK); mean diffusivity (MD) and axonal water fraction (AWF). Automated fiber quantification (AFQ) was used to quantify DKI measurements along the inferior longitudinal (ILF) and uncinate fasciculus (Unc). ILF and Unc tract profiles were compared between groups and tested for correlation with disease duration. To characterize temporopolar cortex microstructure, DKI maps were sampled at varying depths from superficial white matter (WM) towards the pial surface. Patients were separated according to the temporal lobe ipsilateral to seizure onset and their AFQ results were used as input for statistical analyses. Significant differences were observed between lesional TLE and controls, towards the most temporopolar segment of ILF and Unc proximal to the TP within the ipsilateral temporal lobe in left TLE patients for MK, RK, AWF and MD. No significant changes were observed with DKI maps in the non-lesional TLE group. DKI measurements correlated with disease duration, mostly towards the temporopolar segments of the WM bundles. Stronger differences in MK, RK and AWF within the temporopolar cortex were observed in the lesional TLE and noticeable differences (except for MD) in non-lesional TLE groups compared to controls. This study demonstrates that DKI has potential to detect subtle microstructural alterations within the temporopolar segments of the ILF and Unc and the connected temporopolar cortex in TLE patients including non-lesional TLE subjects. This could aid our understanding of the extrahippocampal areas, more specifically the temporal pole role in seizure generation in TLE and might inform surgical planning, leading to better seizure outcomes.


Subject(s)
Epilepsy, Temporal Lobe , White Matter , Humans , Epilepsy, Temporal Lobe/diagnostic imaging , Diffusion Tensor Imaging/methods , Temporal Lobe/diagnostic imaging , White Matter/diagnostic imaging , Seizures
7.
Med Phys ; 49(9): 6055-6067, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35754362

ABSTRACT

BACKGROUND: The use of non-ionizing electric fields from low-intensity voltage sources (< 10 V) to control malignant tumor growth is showing increasing potential as a cancer treatment modality. A method of applying these low-intensity electric fields using multiple implanted electrodes within or adjacent to tumor volumes has been termed as intratumoral modulation therapy (IMT). PURPOSE: This study explores advancements in the previously established IMT optimization algorithm, and the development of a custom treatment planning system for patient-specific IMT. The practicality of the treatment planning system is demonstrated by implementing the full optimization pipeline on a brain phantom with robotic electrode implantation, postoperative imaging, and treatment stimulation. METHODS: The integrated planning pipeline in 3D Slicer begins with importing and segmenting patient magnetic resonance images (MRI) or computed tomography (CT) images. The segmentation process is manual, followed by a semi-automatic smoothing step that allows the segmented brain and tumor mesh volumes to be smoothed and simplified by applying selected filters. Electrode trajectories are planned manually on the patient MRI or CT by selecting insertion and tip coordinates for a chosen number of electrodes. The electrode tip positions and stimulation parameters (phase shift and voltage) can then be optimized with the custom semi-automatic IMT optimization algorithm where users can select the prescription electric field, voltage amplitude limit, tissue electrical properties, nearby organs at risk, optimization parameters (electrode tip location, individual contact phase shift and voltage), desired field coverage percent, and field conformity optimization. Tables of optimization results are displayed, and the resulting electric field is visualized as a field-map superimposed on the MR or CT image, with 3D renderings of the brain, tumor, and electrodes. Optimized electrode coordinates are transferred to robotic electrode implantation software to enable planning and subsequent implantation of the electrodes at the desired trajectories. RESULTS: An IMT treatment planning system was developed that incorporates patient-specific MRI or CT, segmentation, volume smoothing, electrode trajectory planning, electrode tip location and stimulation parameter optimization, and results visualization. All previous manual pipeline steps operating on diverse software platforms were coalesced into a single semi-automated 3D Slicer-based user interface. Brain phantom validation of the full system implementation was successful in preoperative planning, robotic electrode implantation, and postoperative treatment planning to adjust stimulation parameters based on actual implant locations. Voltage measurements were obtained in the brain phantom to determine the electrical parameters of the phantom and validate the simulated electric field distribution. CONCLUSIONS: A custom treatment planning and implantation system for IMT has been developed in this study and validated on a phantom brain model, providing an essential step in advancing IMT technology toward future clinical safety and efficacy investigations.


Subject(s)
Brain Neoplasms , Magnetic Resonance Imaging , Brain/surgery , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Electrodes , Electrodes, Implanted , Humans , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods
8.
IEEE Trans Med Imaging ; 41(11): 3344-3356, 2022 11.
Article in English | MEDLINE | ID: mdl-35724283

ABSTRACT

Complete tumor coverage by the thermal ablation zone and with a safety margin (5 or 10 mm) is required to achieve the entire tumor eradication in liver tumor ablation procedures. However, 2D ultrasound (US) imaging has limitations in evaluating the tumor coverage by imaging only one or multiple planes, particularly for cases with multiple inserted applicators or irregular tumor shapes. In this paper, we evaluate the intra-procedural tumor coverage using 3D US imaging and investigate whether it can provide clinically needed information. Using data from 14 cases, we employed surface- and volume-based evaluation metrics to provide information on any uncovered tumor region. For cases with incomplete tumor coverage or uneven ablation margin distribution, we also proposed a novel margin uniformity -based approach to provide quantitative applicator adjustment information for optimization of tumor coverage. Both the surface- and volume-based metrics showed that 5 of 14 cases had incomplete tumor coverage according to the estimated ablation zone. After applying our proposed applicator adjustment approach, the simulated results showed that 92.9% (13 of 14) cases achieved 100% tumor coverage and the remaining case can benefit by increasing the ablation time or power. Our proposed method can evaluate the intra-procedural tumor coverage and intuitively provide applicator adjustment information for the physician. Our 3D US-based method is compatible with the constraints of conventional US-guided ablation procedures and can be easily integrated into the clinical workflow.


Subject(s)
Catheter Ablation , Liver Neoplasms , Humans , Ultrasonography , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Imaging, Three-Dimensional/methods , Radionuclide Imaging , Catheter Ablation/methods
9.
Int J Comput Assist Radiol Surg ; 17(9): 1569-1577, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35588338

ABSTRACT

PURPOSE: Tricuspid valve (TV) interventions face the challenge of imaging the anatomy and tools because of the 'TEE-unfriendly' nature of the TV. In edge-to-edge TV repair, a core step is to position the clip perpendicular to the coaptation gap. In this study, we provide a semi-automated method to localize the VC from Doppler intracardiac echo (ICE) imaging in a tracked 3D space, thus providing a pre-mapped location of the coaptation gap to assist device positioning. METHODS: A magnetically tracked ICE probe with Doppler imaging capabilities is employed in this study for imaging three patient-specific TVs placed in a pulsatile heart phantom. For each of the valves, the ICE probe is positioned to image the maximum regurgitant flow for five cardiac cycles. An algorithm then extracts the regurgitation imaging and computes the exact location of the vena contracta on the image. RESULTS: Across the three pathological, patient-specific valves, the average distance error between the detected VC and the ground truth model is [Formula: see text]mm. For each of the valves, one case represented the outlier where the algorithm misidentified the vena contracta to be near the annulus. In such cases, it is recommended to retake the five-second imaging data. CONCLUSION: This study presented a method for ultrasound-based localization of vena contracta in 3D space. Mapping such anatomical landmarks has the potential to assist with device positioning and to simplify tricuspid valve interventions by providing more contextual information to the interventionalists, thus enhancing their spatial awareness. Additionally, ICE can be used to provide live US and Doppler imaging of the complex TV anatomy throughout the procedure.


Subject(s)
Cardiac Surgical Procedures , Echocardiography, Three-Dimensional , Cardiac Surgical Procedures/methods , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Humans , Severity of Illness Index , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery
10.
Ultrasound Med Biol ; 48(7): 1290-1298, 2022 07.
Article in English | MEDLINE | ID: mdl-35487839

ABSTRACT

Transcatheter cardiovascular interventions have the advantage of patient safety, reduced surgery time and minimal trauma to the patient's body. Transcathether interventions, which are performed percutaneously, are limited by the lack of direct line of sight with the procedural tools and the patient anatomy. Therefore, such interventional procedures rely heavily on image guidance for navigating toward and delivering therapy at the target site. Vascular navigation via the inferior vena cava, from the groin to the heart, is an imperative part of most transcatheter cardiovascular interventions including heart valve repair surgeries and ablation therapy. Traditionally, the inferior vena cava is navigated using fluoroscopic techniques such as venography and computed tomography venography. These X-ray-based techniques can have detrimental effects on the patient as well as the surgical team, causing increased radiation exposure, leading to risk of cancer, fetal defects and eye cataracts. The use of a heavy lead apron has also been reported to cause back pain and spine issues, thus leading to interventionalist's disc disease. We propose the use of a catheter-based ultrasound augmented with electromagnetic tracking technology to generate a vascular roadmap in real time and perform navigation without harmful radiation. In this pilot study, we used spatially tracked intracardiac echocardiography to reconstruct a vessel from a phantom in a 3-D virtual environment. We illustrate how the proposed ultrasound-based navigation will appear in a virtual environment, by navigating a tracked guidewire within the vessels in the phantom without any radiation-based imaging. The geometric accuracy is assessed using a computed tomography scan of the phantom, with a Dice coefficient of 0.79. The average distance between the surfaces of the two models comes out to be 1.7 ± 1.12 mm.


Subject(s)
Heart , Surgery, Computer-Assisted , Equipment Design , Humans , Phantoms, Imaging , Pilot Projects , Ultrasonography
11.
J Imaging ; 8(1)2022 Jan 07.
Article in English | MEDLINE | ID: mdl-35049848

ABSTRACT

While ultrasound (US) guidance has been used during central venous catheterization to reduce complications, including the puncturing of arteries, the rate of such problems remains non-negligible. To further reduce complication rates, mixed-reality systems have been proposed as part of the user interface for such procedures. We demonstrate the use of a surgical navigation system that renders a calibrated US image, and the needle and its trajectory, in a common frame of reference. We compare the effectiveness of this system, whereby images are rendered on a planar monitor and within a head-mounted display (HMD), to the standard-of-care US-only approach, via a phantom-based user study that recruited 31 expert clinicians and 20 medical students. These users performed needle-insertions into a phantom under the three modes of visualization. The success rates were significantly improved under HMD-guidance as compared to US-guidance, for both expert clinicians (94% vs. 70%) and medical students (70% vs. 25%). Users more consistently positioned their needle closer to the center of the vessel's lumen under HMD-guidance compared to US-guidance. The performance of the clinicians when interacting with this monitor system was comparable to using US-only guidance, with no significant difference being observed across any metrics. The results suggest that the use of an HMD to align the clinician's visual and motor fields promotes successful needle guidance, highlighting the importance of continued HMD-guidance research.

12.
IEEE Trans Med Imaging ; 41(7): 1651-1664, 2022 07.
Article in English | MEDLINE | ID: mdl-35085075

ABSTRACT

Stereo matching has become an active area of research in the field of computer vision. In minimally invasive surgery, stereo matching provides depth information to surgeons, with the potential to increase the safety of surgical procedures, particularly those performed laparoscopically. Many stereo matching methods have been reported to perform well for natural images, but for images acquired during a laparoscopic procedure, they are limited by image characteristics including illumination differences, weak texture content, specular highlights, and occlusions. To overcome these limitations, we propose a robust edge-preserving stereo matching method for laparoscopic images, comprising an efficient sparse-dense feature matching step, left and right image illumination equalization, and refined disparity optimization. We validated the proposed method using both benchmark biological phantoms and surgical stereoscopic data. Experimental results illustrated that, in the presence of heavy illumination differences between image pairs, texture and textureless surfaces, specular highlights and occlusions, our proposed approach consistently obtains a more accurate estimate of the disparity map than state-of-the-art stereo matching methods in terms of robustness and boundary preservation.


Subject(s)
Algorithms , Laparoscopy , Imaging, Three-Dimensional/methods , Lighting , Phantoms, Imaging
13.
Brain Struct Funct ; 227(1): 393-405, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34687354

ABSTRACT

Establishing spatial correspondence between subject and template images is necessary in neuroimaging research and clinical applications such as brain mapping and stereotactic neurosurgery. Our anatomical fiducial (AFID) framework has recently been validated to serve as a quantitative measure of image registration based on salient anatomical features. In this study, we sought to apply the AFIDs protocol to the clinic, focusing on structural magnetic resonance images obtained from patients with Parkinson's disease (PD). We confirmed AFIDs could be placed to millimetric accuracy in the PD dataset with results comparable to those in normal control subjects. We evaluated subject-to-template registration using this framework by aligning the clinical scans to standard template space using a robust open preprocessing workflow. We found that registration errors measured using AFIDs were higher than previously reported, suggesting the need for optimization of image processing pipelines for clinical grade datasets. Finally, we examined the utility of using point-to-point distances between AFIDs as a morphometric biomarker of PD, finding evidence of reduced distances between AFIDs that circumscribe regions known to be affected in PD including the substantia nigra. Overall, we provide evidence that AFIDs can be successfully applied in a clinical setting and utilized to provide localized and quantitative measures of registration error. AFIDs provide clinicians and researchers with a common, open framework for quality control and validation of spatial correspondence and the location of anatomical structures, facilitating aggregation of imaging datasets and comparisons between various neurological conditions.


Subject(s)
Parkinson Disease , Brain Mapping , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Parkinson Disease/diagnostic imaging
14.
Can Assoc Radiol J ; 73(2): 396-402, 2022 May.
Article in English | MEDLINE | ID: mdl-34328021

ABSTRACT

PURPOSE: Assessment of patients for temporal lobe epilepsy (TLE) surgery requires multimodality input, including EEG recordings to ensure optimal surgical planning. Often EEG demonstrates abnormal foci not detected on 1.5T MRI. Ultra-high field MRI at 7T provides improved resolution of the brain. We investigated the utility of 7T MRI to detect potential anatomical abnormalities associated with EEG changes. METHODS: Ultra-high field data were acquired on a 7T MRI scanner for 13 patients with history of drug resistant TLE who had had EEG telemetry recordings. Qualitative evaluation of 7T imaging for presence of focal abnormalities detected on EEG was performed. Correlation of 7T MRI findings with EEG recordings of focal slowing or interictal epileptic spikes (IEDs), and seizures was performed. RESULTS: Assessment of 7T MRI demonstrated concordance with TLE as determined by the multidisciplinary team in 61.5% of cases (n = 8). Among these, 3 patients exhibited supportive abnormal 7T MRI abnormalities not detected by 1.5T MRI. In patients who underwent surgery, 72.7% had concordant histopathology findings with 7T MRI findings (n = 8). However, qualitative assessment of 7T images revealed focal anatomical abnormalities to account for EEG findings in only 15.4% of patients (n = 2). Other regions that were found to have localized IEDs in addition to the lesional temporal lobe, included the contralateral temporal lobe (n = 5), frontal lobe (n = 3), and parieto-occipital lobe (n = 2). CONCLUSION: Ultra-high field 7T MRI findings show concordance with clinical data. However, 7T MRI did not reveal anatomical findings to account for abnormalities detected by EEG.


Subject(s)
Epilepsy, Temporal Lobe , Epilepsy , Electroencephalography , Epilepsy/diagnostic imaging , Epilepsy/surgery , Epilepsy, Temporal Lobe/diagnostic imaging , Epilepsy, Temporal Lobe/surgery , Humans , Magnetic Resonance Imaging/methods , Temporal Lobe
15.
Surg Endosc ; 36(5): 3169-3177, 2022 05.
Article in English | MEDLINE | ID: mdl-34231070

ABSTRACT

BACKGROUND: Colonoscopy is a technically challenging procedure. The colonoscope is prone to forming loops in the colon, which can lead patient discomfort and even perforation. We hypothesized that expert endoscopists use techniques to avoid loop formation, identify and straighten loops earlier, and thus exert less force. METHODS: Using a commercially available physical colon simulator model (Kyoto Kagaku), electromagnetic tracking markers (NDI Medical) were placed along the mobile segments of the colon (sigmoid, transverse) to measure the degree of displacement of the colon as the scope was advanced to the cecum. The colon model was set for each participant to simulate a redundant alpha loop in the sigmoid colon. Gastroenterology and surgical trainees and attendings were assessed. Demographic data were collected for each participant. RESULTS: Seventy-five participants were enrolled in the study. There were 17 (22.7%) attending physicians, and 58 (77.3%) trainees. Attending physicians advanced the scope to the cecum faster. The mean time required for procedure completion was 360.5 s compared to 178.4 s for the trainee and attending groups respectively (mean difference: 182.1 s, 95% CI: 93.0, 269.7; p = 0.0002). Attending physicians exerted significantly lower mean colonic displacement than trainees. The mean colonic displacement was 79.8 mm for the trainee group and 57.9 mm for the attending group (mean difference: 21.9 mm, 95% CI: 2.6, 41.2; p = 0.04). Those who used torque steering caused lower maximum colonic displacement than those who used knob steering. CONCLUSION: Attending physicians advance the scope during colonoscopy in a manner that results in significantly less colonic displacement than resident trainees. Although prior studies have shown a difference in force application between endoscopists and inexperienced students, ours is the first to differentiate across varying degrees of endoscopic skill. Future studies will define metrics for incorporation into endoscopic training curricula, focusing on techniques that encourage safety and comfort for patients.


Subject(s)
Clinical Competence , Colonoscopes , Colon , Colonoscopy/methods , Endoscopy, Gastrointestinal , Humans
16.
Sci Rep ; 11(1): 15576, 2021 08 02.
Article in English | MEDLINE | ID: mdl-34341427

ABSTRACT

Growing evidence suggests an association of lumbar paraspinal muscle morphology with low back pain (LBP) and lumbar pathologies. Unilateral spinal disorders provide unique models to study this association, with implications for diagnosis, prognosis, and management. Statistical shape analysis is a technique that can identify signature shape variations related to phenotypes but has never been employed in studying paraspinal muscle morphology. We present the first investigation using this technique to reveal disease-related paraspinal muscle asymmetry, using MRIs of patients with a single posterolateral disc herniation at the L5-S1 spinal level and unilateral leg pain. Statistical shape analysis was conducted to reveal disease- and phenotype-related morphological variations in the multifidus and erector spinae muscles at the level of herniation and the one below. With the analysis, shape variations associated with disc herniation were identified in the multifidus on the painful side at the level below the pathology while no pathology-related asymmetry in cross-sectional area (CSA) and fatty infiltration was found in either muscle. The results demonstrate higher sensitivity and spatial specificity for the technique than typical CSA and fatty infiltration measures. Statistical shape analysis holds promise in studying paraspinal muscle morphology to improve our understanding of LBP and various lumbar pathologies.


Subject(s)
Intervertebral Disc Displacement/pathology , Lumbar Vertebrae/pathology , Paraspinal Muscles/pathology , Statistics as Topic , Adult , Female , Humans , Intervertebral Disc Displacement/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Male , Organ Size , Paraspinal Muscles/diagnostic imaging
17.
Hum Brain Mapp ; 42(14): 4465-4477, 2021 10 01.
Article in English | MEDLINE | ID: mdl-34106502

ABSTRACT

Parkinson's disease (PD) is a progressive neurodegenerative disorder that is characterized by a range of motor and nonmotor symptoms, often with the motor dysfunction initiated unilaterally. Knowledge regarding disease-related alterations in white matter pathways can effectively help improve the understanding of the disease and propose targeted treatment strategies. Microstructural imaging techniques, including diffusion tensor imaging (DTI), allows inspection of white matter integrity to study the pathogenesis of various neurological conditions. Previous voxel-based analyses with DTI measures, such as fractional anisotropy and mean diffusivity have uncovered changes in brain regions that are associated with PD, but the conclusions were inconsistent, partially due to small patient cohorts and the lack of consideration for clinical laterality onset, particularly in early PD. Fixel-based analysis (FBA) is a recent framework that offers tract-specific insights regarding white matter health, but very few FBA studies on PD exist. We present a study that reveals strengthened and weakened white matter integrity that is subject to symptom laterality in a large drug-naïve de novo PD cohort using complementary DTI and FBA measures. The findings suggest that the disease gives rise to tissue degeneration and potential re-organization in the early stage.


Subject(s)
Diffusion Tensor Imaging , Parkinson Disease/pathology , White Matter/pathology , Aged , Cohort Studies , Female , Humans , Male , Middle Aged , Parkinson Disease/diagnostic imaging , White Matter/diagnostic imaging
19.
Comput Med Imaging Graph ; 88: 101850, 2021 03.
Article in English | MEDLINE | ID: mdl-33418302

ABSTRACT

Dual-modality 4D cardiac data visualization can convey a significant amount of complementary image information from various sources into a single and meaningful display. Even though there are existing publications on combining multiple medical images into a unique representation, there has been no work on rendering a series of cardiac image sequences, acquired from multiple sources, using web browsers and synchronizing the result over the Internet in real time. The ability to display multi-modality beating heart images using Web-based technology is hampered by the lack of efficient algorithms for fusing and visualizing constantly updated multi-source images and streaming the rendering results using internet protocols. To address this practical issue, in this paper we introduce a new Internet-based algorithm and a software platform running on a Node.js server, where a series of registered cardiac images from both magnetic resonance (MR) and ultrasound are employed to display dynamic fused cardiac structures in web browsers. Taking advantage of the bidirectional WebSocket protocol and WebGL-based graphics acceleration, internal cardiac structures are dynamically displayed, and the results of rendering and data exploration are synchronized among all the connected client computers. The presented research and software have the potential to provide clinicians with comprehensive information and intuitive feedback relating to cardiac behavior and anatomy and could impact areas such as distributed diagnosis of cardiac function and collaborative treatment planning for various heart diseases.


Subject(s)
Computer Graphics , Software , Algorithms , Humans , Internet , Magnetic Resonance Spectroscopy
20.
J Magn Reson Imaging ; 53(4): 1175-1187, 2021 04.
Article in English | MEDLINE | ID: mdl-33098227

ABSTRACT

BACKGROUND: Diffusion kurtosis imaging (DKI) quantifies the non-Gaussian diffusion of water within tissue microstructure. However, it has increased fitting parameters and requires higher b-values. Evaluation of DKI reproducibility is important for clinical purposes. PURPOSE: To assess the reproducibility in whole-brain high-resolution DKI at varying b-values. STUDY TYPE: Retrospective. SUBJECTS AND PHANTOMS: In all, 44 individuals from the test-retest Human Connectome Project (HCP) database and 12 3D-printed phantoms. FIELD STRENGTH/SEQUENCE: Diffusion-weighted multiband echo-planar imaging sequence at 3T and 9.4T. magnetization-prepared rapid acquisition gradient echo at 3T for in vivo structural data only. ASSESSMENT: From HCP data with b-values = 1000, 2000, 3000 s/mm2 (dataset A), two additional datasets with b-values = 1000, 3000 s/mm2 (dataset B) and b-values = 1000, 2000 s/mm2 (dataset C) were extracted. Estimated DKI metrics from each dataset were used for evaluating reproducibility and fitting quality in white matter (WM) and gray matter (GM) based on whole-brain and regions of interest (ROIs). STATISTICAL TESTS: DKI reproducibility was assessed using the within-subject coefficient of variation (CoV), fitting residuals to evaluate DKI fitting accuracy and Pearson's correlation to investigate the presence of systematic biases. Repeated measures analysis of variance was used for statistical comparison. RESULTS: Datasets A and B exhibited lower DKI CoVs (<20%) compared to C (<50%) in both WM and GM ROIs (all P < 0.05). This effect varies between DKI and DTI parameters (P < 0.005). Whole-brain fitting residuals were consistent across datasets (P > 0.05), but lower residuals in dataset B were detected for the WM ROIs (P < 0.001). A similar trend was observed for the phantom data CoVs (<7.5%) at varying fiber orientations for datasets A and B. Finally, dataset C was characterized by higher residuals across the different fiber crossings (P < 0.05). DATA CONCLUSION: The study demonstrates that high reproducibility can still be achieved within a reasonable scan time, specifically dataset B, supporting the potential of DKI for aiding clinical tools in detecting microstructural changes.


Subject(s)
Brain/diagnostic imaging , Diffusion Tensor Imaging/methods , Image Processing, Computer-Assisted/methods , Adult , Echo-Planar Imaging , Female , Humans , Male , Phantoms, Imaging , Reproducibility of Results , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...