Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 8(1): 9156, 2018 06 14.
Article in English | MEDLINE | ID: mdl-29904138

ABSTRACT

Sepsis is a common and often deadly systemic response to an infection, usually caused by bacteria. The gold standard for finding the causing pathogen in a blood sample is blood culture, which may take hours to days. Shortening the time to diagnosis would significantly reduce mortality. To replace the time-consuming blood culture we are developing a method to directly separate bacteria from red and white blood cells to enable faster bacteria identification. The blood cells are moved from the sample flow into a parallel stream using acoustophoresis. Due to their smaller size, the bacteria are not affected by the acoustic field and therefore remain in the blood plasma flow and can be directed to a separate outlet. When optimizing for sample throughput, 1 ml of undiluted whole blood equivalent can be processed within 12.5 min, while maintaining the bacteria recovery at 90% and the blood cell removal above 99%. That makes this the fastest label-free microfluidic continuous flow method per channel to separate bacteria from blood with high bacteria recovery (>80%). The high throughput was achieved by matching the acoustic impedance of the parallel stream to that of the blood sample, to avoid that acoustic forces relocate the fluid streams.


Subject(s)
Acoustics/instrumentation , Blood Cells/cytology , Cell Separation , Pseudomonas aeruginosa/isolation & purification , Pseudomonas putida/isolation & purification , Cell Separation/instrumentation , Cell Separation/methods , Humans , Pseudomonas aeruginosa/cytology , Pseudomonas putida/cytology
2.
Anal Chim Acta ; 1000: 199-204, 2018 Feb 13.
Article in English | MEDLINE | ID: mdl-29289309

ABSTRACT

Hematocrit (HCT) measurements of blood from patients, blood donors and athletes are routinely performed on a daily basis. These measurements are often performed in centralized hospital labs by whole blood analyzers, which leads to long time-to-result. On site measurements, based on centrifugation can be done, but these assays require manual handling, are slow and can just measure HCT in contrast to the central lab whole blood analyzers. In this work, we present a microfluidic based method to measure HCT in blood samples by acoustic separation of whole blood into discrete regions of plasma and red blood cells. Comparison of the areas of the red blood cell and plasma regions gives an accurate HCT value, with a linear correlation to the centrifugation-based reference method. A readout can be performed within 2 s of acoustic actuation providing a readout accuracy of approximately 3% points (pp) HCT. Additional accuracy can be achieved by extending the acoustic actuation to 20 s, yielding an error of less than 1 pp HCT. This acoustic tool is optimal for integration into a lab-on-a-chip device with in-line measurements of different clinical parameters.


Subject(s)
Acoustics , Erythrocytes/cytology , Hematocrit , Microfluidic Analytical Techniques , Healthy Volunteers , Humans
3.
Anal Chem ; 88(19): 9403-9411, 2016 10 04.
Article in English | MEDLINE | ID: mdl-27264110

ABSTRACT

This paper describes an integrated microsystem for rapid separation, enrichment, and detection of bacteria from blood, addressing the unmet clinical need for rapid sepsis diagnostics. The blood sample is first processed in an acoustophoresis chip, where red blood cells are focused to the center of the channel by an acoustic standing wave and sequentially removed. The bacteria-containing plasma proceeds to a glass capillary with a localized acoustic standing wave field where the bacteria are trapped onto suspended polystyrene particles. The trapped bacteria are subsequently washed while held in the acoustic trap and released into a polymer microchip containing dried polymerase chain reaction (PCR) reagents, followed by thermocycling for target sequence amplification. The entire process is completed in less than 2 h. Testing with Pseudomonas putida spiked into whole blood revealed a detection limit of 1000 bacteria/mL for this first-generation analysis system. In samples from septic patients, the system was able to detect Escherichia coli in half of the cases identified by blood culture. This indicates that the current system detects bacteria in patient samples in the upper part of the of clinically relevant bacteria concentration range and that a further developed acoustic sample preparation system may open the door for a new and faster automated method to diagnose sepsis.


Subject(s)
Blood Culture/methods , Blood/microbiology , Microchip Analytical Procedures/methods , Sepsis/blood , Sepsis/diagnosis , Acoustics , Escherichia coli , Humans , Limit of Detection , Polymerase Chain Reaction , Pseudomonas putida
SELECTION OF CITATIONS
SEARCH DETAIL
...