Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Clin Pathol ; 112(5): 712-9, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10549259

ABSTRACT

We report an evaluation of current laboratory and clinical practice for the diagnosis and management of von Willebrand disease (VWD) for a wide geographic area including Australia, New Zealand, and parts of Southeast Asia. This assessment has been undertaken in conjunction with the RCPA Quality Assurance Program (QAP) in Haematology. This external QAP currently comprises around 550 participating laboratories, of which some 450 perform coagulation testing, and from which 32 laboratories were identified to be actively involved in testing for VWD. These laboratories were targeted and their current laboratory and clinical practice evaluated by using various questionnaires. Our overall findings indicate a wide variation in laboratory test practice for VWD-based investigations. There was considerable variation among laboratories in the tests and test methods used, the control and calibration material used, the reported test reference intervals and units used, and the composite test panels used to diagnose VWD. However, substantial consensus in the clinical evaluation process, as undertaken by hematologists, also was identified. Despite the observed variations, most laboratory professionals seemed to understand the complexities involved in the diagnosis and subclassification of VWD, and the laboratories can provide an effective diagnostic service.


Subject(s)
Hematologic Tests/standards , Practice Patterns, Physicians' , von Willebrand Diseases , von Willebrand Factor/analysis , Asia, Southeastern , Australia , Evaluation Studies as Topic , Hematologic Tests/methods , Humans , Multicenter Studies as Topic , New Zealand , Quality Assurance, Health Care , Reference Values , Surveys and Questionnaires , von Willebrand Diseases/blood , von Willebrand Diseases/diagnosis , von Willebrand Diseases/therapy
2.
Thromb Haemost ; 82(4): 1276-82, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10544913

ABSTRACT

We report an evaluation of current laboratory practice for the diagnosis of von Willebrand's disease (VWD) by means of a multilaboratory survey. This assessment was undertaken with the RCPA Quality Assurance Program (QAP) in Haematology, which covers a wide geographic area encompassing Australia, New Zealand and Asia. A total of 25 laboratories actively involved in testing for VWD were selected to participate in a sample testing assessment exercise. Samples comprised 10 plasmas: (i) a normal plasma pool (in duplicate), (ii) this pool diluted to 50% (in duplicate), (iii) a normal individual (X1), (iv) severe Type 1 VWD (X1), (v) Type 2B VWD (x2 unrelated donors), (vi) Type 3 VWD (x1), (vii) Type 2A VWD (x1). Laboratories were asked to perform all tests available to them in order to establish a laboratory diagnosis of VWD, and then to comment on the possibility or otherwise of VWD. Overall findings indicated a wide variation in test practice, in the effectiveness of various test procedures in detecting VWD, and in the ability of various composite test panels to identify type 2 VWD subtypes. Firstly, while all laboratories (n = 25) performed tests for FVIII:C activity, von Willebrand factor 'antigen' (VWF:Ag) and a functional VWF assay [using the ristocetin cofactor assay (VWF:RCo; n = 23) and/or the collagen binding assay (VWF:CBA; n = 12)], only three laboratories carried out VWF:Multimer analysis. Secondly, for the three quantitative VWF assays, 10/25 (40%) laboratories performed all three, whereas 15/25 (60%) performed only two [VWF:Ag and VWF:RCo (n = 13); VWF:Ag and VWF:CBA (n = 2)]. Thirdly, a variety of assay methodologies were evident for VWF:Ag [ELISA, electro-immuno diffusion (EID), latex immuno-assay (LIA), and VIDAS assay] and VWF:RCo (platelet agglutination/'aggregometry' and a 'functional VWF:RCo-alternative' ELISA assay). Between method analysis for the quantitative VWF assays showed that the VWF:RCo yielded the greatest degree of inter-laboratory assay variation, and had the poorest overall performance with respect to sensitivity to low levels of VWF. The VWF:CBA also performed better than the VWF:RCo in terms of ability to detect functional VWF 'discordance' (i.e. Type 2 VWD). Within VWF:Ag method analysis showed that the EID assay procedure was associated with the greatest variation in assay results, while the EID and LIA test methods showed poorer sensitivity at low VWF levels compared to the ELISA method. Within the VWF:RCo assay procedure, greatest variation in assay results and poorest sensitivity to low VWF levels was obtained using the agglutination method; however, the agglutination procedure showed better performance than the 'functional VWF:RCo-alternative' ELISA assay in identifying Type 2 VWD plasma samples. Finally, despite identified variations, most laboratories appeared to understand the complexities involved in the VWD-diagnostic process, and made appropriate diagnostic predictions regarding tested samples. From a total possible 246 interpretation events, laboratories in most cases correctly identified normal samples as normal (67/75 events = 89%), and VWD samples as derived from individuals with VWD (117/121 events = 97%). Moreover, when VWD was suggested by laboratory findings, laboratories usually correctly predicted the general subtype of VWD present (96/109 events = 88%). When 'misinterpretations' occurred, these could often be linked to the test panels utilised by laboratories. That is, laboratories using the VWF:Ag and VWF:RCo combination were more likely to incorrectly identify samples derived from Type 2 VWD patients as being Type 1, Type 1 VWD patients as being Type 2, and normal plasma samples as potentially derived from patients with VWD, compared to those using the VWF:Ag and VWF:CBA.


Subject(s)
Clinical Laboratory Techniques/standards , von Willebrand Diseases/diagnosis , Evaluation Studies as Topic , Health Surveys , Humans , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...