Biomed Tech (Berl) ; 60(4): 301-16, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26352349

ABSTRACT

Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 µl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 µl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.


Subject(s)
Calibration/standards , Chromatography, Liquid/instrumentation , Humans , Nanotechnology
2.
Biomed Tech (Berl) ; 60(4): 337-45, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26154192

ABSTRACT

This work presents the improvements of an experimental setup for measuring ultra-low flow rates down to 5 nl/min. The system uses a telecentric CCD imaging system mounted on a high-precision, computer-controlled linear stage to track a moving liquid meniscus inside a glass capillary. Compared to the original setup, the lowest attainable expanded uncertainty at any flow rate has been reduced from 5.4% to 2%. In addition, the conformity with specification of three commercial micro-fluidic devices was evaluated using the new setup: one syringe pump, one implantable infusion pump and one thermal flow sensor. The flow sensor and the implantable infusion pump met the compliance criteria (coverage probability 95%). The syringe pump however, failed to meet the specifications at 5 nl/min and 10 nl/min. No assessment could be made at higher flow rates.


Subject(s)
Calibration , Syringes/standards , Humans , Infusion Pumps , Infusion Pumps, Implantable
3.
Biomed Tech (Berl) ; 60(4): 347-57, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25945719

ABSTRACT

For critical drug delivery, it is important to have a constant and well-known infusion rate delivered by the complete infusion set-up (pump, tubing, and accessories). Therefore, various drug delivery devices and accessories were tested in this article in terms of their infusion accuracy, start-up delay, response time, and dependency on the viscosity. These measurements were performed as part of the European funded research project MeDD. The obtained results show that the infusion accuracy of the devices is flow rate and accessory depended, especially for low flow rates. Viscosity does not have a significant impact on the flow rate accuracy.


Subject(s)
Drug Delivery Systems/methods , Equipment Design/instrumentation , Research Design , Viscosity