Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Neurourol Urodyn ; 40(2): 714-721, 2021 02.
Article in English | MEDLINE | ID: mdl-33508155

ABSTRACT

AIMS: Sacral neuromodulation (SNM) is a guideline-recommended treatment with proven therapeutic benefit for urinary urgency incontinence (UUI) patients. The Axonics® System is the first Food and Drug Administration-approved rechargeable SNM system and is designed to deliver therapy for a minimum of 15 years. The ARTISAN-SNM study was designed to evaluate UUI participants treated with the Axonics System. Two-year follow-up results are presented. METHODS: One hundred and twenty-nine UUI participants underwent implantation with the Axonics System. Therapeutic response rate, participant quality of life (QoL), and satisfaction were determined using 3-day voiding diaries, ICIQ-OABqol, and satisfaction questionnaires. Participants were considered responders if they had a 50% or greater reduction in UUI episodes post-treatment. As-treated and Completers analyses are presented. RESULTS: At 2 years, 93% of the participants (n = 121 Completers at 2 years) were therapy responders, of which 82% achieved ≥ 75% reduction in UUI episodes and 37% were dry (100% reduction). Daily UUI episodes reduced from 5.6 ± 0.3 at baseline to 1.0 ± 0.2 at 2 years. Statistically significant improvements in ICIQ-OABqol were reported. All participants were able to recharge their device and 94% of participants reported that the recharging frequency and duration were acceptable. Participant demographics nor condition severity were correlated with clinical outcomes or recharging experience. No unanticipated or serious device-related adverse events occurred. CONCLUSIONS: At 2 years, participants treated with the Axonics System demonstrated sustained safety and efficacy, high levels of satisfaction with therapy and recharging. Participant-related factors were not associated with efficacy or recharging outcomes, indicating the reported results are applicable to a diverse population.


Subject(s)
Electric Stimulation Therapy/methods , Quality of Life/psychology , Sacrum/physiopathology , Urinary Incontinence, Urge/therapy , Female , Follow-Up Studies , Humans , Male , Time Factors , Treatment Outcome
2.
Neurourol Urodyn ; 39(5): 1482-1488, 2020 06.
Article in English | MEDLINE | ID: mdl-32339339

ABSTRACT

AIMS: Sacral neuromodulation (SNM) is a guideline-recommended treatment for voiding dysfunction including urgency, urge incontinence, and nonobstructive retention as well as fecal incontinence. The Axonics® System is a miniaturized, rechargeable SNM system designed to provide therapy for at least 15 years, which is expected to significantly reduce revision surgeries as it will not require replacement as frequently as the non-rechargeable SNM system. The ARTISAN-SNM study is a pivotal study designed to treat patients with urinary urgency incontinence (UUI). Clinical results at 1-year are presented. METHODS: A total of 129 eligible UUI patients were treated. All participants were implanted with a quadripolar tined lead and neurostimulator in a single procedure. Efficacy data were collected using a 3-day bladder diary, a validated quality of life questionnaire (ICIQ-OABqol), and a participant satisfaction questionnaire. Therapy responders were defined as participants with ≥50% reduction in UUI episodes compared to baseline. Data were analyzed on all 129 participants. RESULTS: At 1 year, 89% of the participants were therapy responders. The average UUI episodes per day reduced from 5.6 ± 0.3 at baseline to 1.4 ± 0.2. Participants experienced an overall clinically meaningful improvement of 34 points on the ICIQ-OABqol questionnaire. All study participants (100%) were able to recharge their device at 1 year, and 96% of participants reported that the frequency and duration of recharging was acceptable. There were no serious device-related adverse events. CONCLUSIONS: The Axonics System is safe and effective at 1 year, with 89% of participants experiencing clinically and statistically significant improvements in UUI symptoms.


Subject(s)
Electric Stimulation Therapy/instrumentation , Electrodes, Implanted , Lumbosacral Plexus/surgery , Urinary Incontinence, Urge/therapy , Urologic Surgical Procedures/methods , Adult , Aged , Aged, 80 and over , Electric Stimulation Therapy/adverse effects , Electric Stimulation Therapy/methods , Electrodes, Implanted/adverse effects , Fecal Incontinence/complications , Fecal Incontinence/epidemiology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Patient Satisfaction , Prostheses and Implants , Quality of Life , Surveys and Questionnaires , Treatment Outcome , Urinary Incontinence, Urge/psychology , Urinary Retention/complications , Urinary Retention/therapy , Young Adult
3.
J Urol ; 203(1): 185-192, 2020 01.
Article in English | MEDLINE | ID: mdl-31347955

ABSTRACT

PURPOSE: Sacral neuromodulation is a guideline recommended treatment of urinary dysfunction and fecal incontinence in patients in whom conservative treatments have failed. Historically sacral neuromodulation has been delivered using a nonrechargeable device with an average life span of 4.4 years. Surgery is required to replace the implanted neurostimulator due to battery depletion. Implantation of a long-lived implanted neurostimulator can eliminate the need for replacement surgeries, potentially reducing patient surgical risks and health care costs. The Axonics r-SNM System™ is a miniaturized, rechargeable sacral neuromodulation system designed to deliver therapy for at least 15 years. The ARTISAN-SNM (Axonics® Sacral Neuromodulation System for Urinary Urgency Incontinence Treatment) study is a pivotal study using rechargeable sacral neuromodulation therapy to treat urinary urgency incontinence. Six-month results are presented. MATERIALS AND METHODS: A total of 129 eligible patients with urinary urgency incontinence were treated. All participants were implanted with a tined lead and the rechargeable sacral neuromodulation system in a nonstaged procedure. Efficacy data were collected using a 3-day bladder diary, the validated ICIQ-OABqol (International Consultation on Incontinence Questionnaire Overactive Bladder quality of life) questionnaire and a participant satisfaction questionnaire. Therapy responders were identified as participants with a 50% or greater reduction in urinary urgency incontinence episodes compared to baseline. We performed an as-treated analysis in all implanted participants. RESULTS: At 6 months 90% of participants were therapy responders. The mean ± SE number of urinary urgency incontinence episodes per day was reduced from 5.6 ± 0.3 at baseline to 1.3 ± 0.2. Participants experienced a clinically meaningful 34-point improvement on the ICIQ-OABqol questionnaire. There were no serious device related adverse events. CONCLUSIONS: The Axonics r-SNM System is safe and effective with 90% of participants experiencing clinically and statistically significant improvements in urinary urgency incontinence symptoms.


Subject(s)
Implantable Neurostimulators , Urinary Incontinence, Urge/therapy , Adult , Aged , Aged, 80 and over , Electric Power Supplies , Female , Humans , Male , Middle Aged , Patient Satisfaction , Quality of Life , Sacrum , Urinary Incontinence, Urge/physiopathology
5.
Lasers Surg Med ; 51(9): 760-766, 2019 11.
Article in English | MEDLINE | ID: mdl-31172580

ABSTRACT

BACKGROUND AND OBJECTIVES: Urinary incontinence is a common and distressing condition which interferes with everyday life. Patients frequently experience discomfort related to urine leakage and the subsequent need to use absorbent pads. Since the continence mechanism is primarily maintained by a proper function of pelvic floor muscles (PFM), many treatment methods focused on strengthening of the PFM have been introduced in the past. The aim of this study was to evaluate the safety and efficacy of a high-intensity focused electromagnetic technology (HIFEM) for treatment of urinary incontinence with emphasis on effects on prospective patients' quality of life. STUDY DESIGN/MATERIALS AND METHODS: The study followed an institutional review board approved protocol. A total of 75 women (55.45 ± 12.80 years, 1.85 ± 1.28 deliveries) who showed symptoms of stress, urge, or mixed urinary incontinence were enrolled. They received six HIFEM treatments (2 per week) in duration of 28 minutes. Outcomes were evaluated after the sixth treatment and at the 3-month follow-up. The primary outcome was to assess changes in urinary incontinence by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) and changes in the number of absorbent pads used per day. The secondary outcome was subjective evaluation of the therapy and self-reported changes in quality of life. The statistical analysis was conducted by paired T-test and Pearson correlation coefficient ( α = 0.05). RESULTS: After the sixth session, 61 out of 75 patients (81.33%) reported significant reduction of their symptoms. The average improvement of 49.93% in ICIQ-SF score was observed after the sixth treatment, which further increased to 64.42% at the follow-up (both P < 0.001). Individually, the highest level of improvement was reached in patients suffering from mixed urinary incontinence (69.90%). The reduction of absorbent pads averaged 43.80% after the sixth treatment and 53.68% at 3 months (both P < 0.001), while almost 70% of patients (30 out of 43) reported decreased number of used pads. At the follow-up, a highly significant medium correlation (r = 0.53, P < 0.001) was found between the ICIQ-SF score improvement and the reduction in pad usage. A substantial decrease in the frequency of urine leakage triggers was documented. Patients reported no pain, downtime or adverse events, and also reported additional beneficial effects of the therapy such as increased sexual desire and better urination control. CONCLUSIONS: This study demonstrated that HIFEM technology is able to safely and effectively treat a wide range of patients suffering from urinary incontinence. After six treatments, an improvement in ICIQ-SF score and reduction in absorbent pads usage was observed. Based on subjective evaluation, these changes positively influenced quality of life. © 2019 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Subject(s)
Magnetic Field Therapy , Quality of Life , Urinary Incontinence/therapy , Adult , Aged , Female , Humans , Magnetic Field Therapy/adverse effects , Magnetic Field Therapy/instrumentation , Magnetic Field Therapy/methods , Middle Aged , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...