Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Glob Heart ; 23: 28, 2024.
Article in English | MEDLINE | ID: mdl-38737456

ABSTRACT

Background: Patients diagnosed with Marfan syndrome or a related syndrome require frequent aorta monitoring using imaging techniques like transthoracic echocardiography (TTE) and computed tomography (CT). Accurate aortic measurement is crucial, as even slight enlargement (>2 mm) often necessitates surgical intervention. The 2022 ACC/AHA guideline for Aortic Disease Diagnosis and Management includes updated imaging recommendations. We aimed to compare these with the 2010 guideline. Methods: This retrospective study involved 137 patients with Marfan syndrome or a related disorder, undergoing TTE and ECG-triggered CT. Aortic diameter measurements were taken based on the old 2010 guideline (TTE: inner edge to inner edge, CT: external diameter) and the new 2022 guideline (TTE: leading edge to leading edge, CT: internal diameter). Bland-Altman plots compared measurement differences. Results: Using the 2022 guideline significantly reduced differences outside the clinical agreement limit from 49% to 26% for the aortic sinus and from 41% to 29% for the ascending aorta. Mean differences were -0.30 mm for the aortic sinus and +1.12 mm for the ascending aorta using the 2022 guideline, compared to -2.66 mm and +1.21 mm using the 2010 guideline. Conclusion: This study demonstrates for the first time that the 2022 ACC/AHA guideline improves concordance between ECG-triggered CT and TTE measurements in Marfan syndrome patients, crucial for preventing life-threatening aortic complications. However, the frequency of differences >2 mm remains high. Clinical Relevance/Application: Accurate aortic diameter measurement is vital for patients at risk of fatal aortic complications. While the 2022 guideline enhances concordance between imaging modalities, frequent differences >2 mm persist, potentially impacting decisions on aortic repair. The risk of repeat radiation exposure from ECG-triggered CT, considered the 'gold standard', continues to be justified.


Subject(s)
Echocardiography , Marfan Syndrome , Tomography, X-Ray Computed , Humans , Marfan Syndrome/diagnostic imaging , Marfan Syndrome/diagnosis , Retrospective Studies , Male , Female , Echocardiography/methods , Adult , Tomography, X-Ray Computed/methods , Middle Aged , Practice Guidelines as Topic , United States/epidemiology , Young Adult , Aorta/diagnostic imaging , Adolescent
2.
Diagnostics (Basel) ; 13(20)2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37892098

ABSTRACT

Marfan syndrome (MFS) is an autosomal-dominant multisystem connective tissue disorder that is based on mutations in the FBN1 gene and variably affects different organs, including the heart. In this study, we investigated cardiac function with a focus on the left atrium (LA) in a relatively large cohort of patients with MFS. After screening of 1165 patients that had been examined in our center between 2016 and 2020, 231 adult MFS patients with and without aortic operation were included in our study and compared to a healthy control group (n = 106). Cardiac function was assessed by transthoracic echocardiography and NT-proBNP was used as a secretory marker. Most (94.8%) of the patients received genetic testing. Left ventricular function was within normal ranges and not impaired. Interestingly, we found that LA size and secretory activity were increased in MFS patients, despite normal left ventricular filling pressures. This finding was even more pronounced in MFS patients with prior aortic surgery. A correlation between LA size or NT-proBNP levels and the type of pathogenic FBN1 variant could not be identified. Right ventricular function and right atrial size were increased only in MFS patients that had undergone aortic surgery. In conclusion, these findings suggest that MFS leads to structural changes in the LA that are not solely resulting from left ventricular dysfunction, but probably can be considered a primary pathology of MFS.

3.
Sci Rep ; 12(1): 15333, 2022 09 12.
Article in English | MEDLINE | ID: mdl-36097197

ABSTRACT

Patients with Marfan syndrome and related disorders are at risk for aortic dissection and aortic rupture and therefore require appropriate monitoring. Computed tomography (CT) and transthoracic echocardiography (TTE) are routinely used for initial diagnosis and follow-up. The purpose of this study is to compare whole-heart CT and TTE aortic measurement for initial work-up, 2-year follow-up, and detection of progressive aortic enlargement. This retrospective study included 95 patients diagnosed with Marfan syndrome or a related disorder. All patients underwent initial work-up including aortic diameter measurement using both electrocardiography-triggered whole-heart CT and TTE. Forty-two of these patients did not undergo aortic repair after initial work-up and were monitored by follow-up imaging within 2 years. Differences between the two methods for measuring aortic diameters were compared using Bland-Altman plots. The acceptable clinical limit of agreement (acLOA) for initial work-up, follow-up, and progression within 2 years was predefined as < ± 2 mm. Bland-Altman analysis revealed a small bias of 0.2 mm with wide limits of agreement (LOA) from + 6.3 to - 5.9 mm for the aortic sinus and a relevant bias of - 1.6 mm with wide LOA from + 5.6 to - 8.9 mm for the ascending aorta. Follow-up imaging yielded a small bias of 0.5 mm with a wide LOA from + 6.7 to - 5.8 mm for the aortic sinus and a relevant bias of 1.1 mm with wide LOA from + 8.1 to - 10.2 mm for the ascending aorta. Progressive aortic enlargement at follow-up was detected in 57% of patients using CT and 40% of patients using TTE. Measurement differences outside the acLOA were most frequently observed for the ascending aorta. Whole-heart CT and TTE measurements show good correlation, but the frequency of measurement differences outside the acLOA is high. TTE systematically overestimates aortic diameters. Therefore, whole-heart CT may be preferred for aortic monitoring of patients with Marfan syndrome and related disorders. TTE remains an indispensable imaging tool that provides additional information not available with CT.


Subject(s)
Marfan Syndrome , Echocardiography/methods , Follow-Up Studies , Humans , Marfan Syndrome/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...