Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 918: 69-76, 2016 Apr 28.
Article in English | MEDLINE | ID: mdl-27046212

ABSTRACT

This study reports multiplex sorting of Salmonella typhimurium and Escherichia coli 0157, from broth cultures and from pathogen-spiked skinned chicken breast enrichment broths by employing microfluidic free-flow magnetophoresis. Magnetic beads of different sizes and magnetite content, namely Dynabeads anti-salmonella and Hyglos-Streptavidin beads together with the corresponding pathogen-specific biotinylated recombinant phages, were utilised as affinity solid phases for the capture and concentration of viable S. typhimurium and E. coli 0157. Following optimisation, the protocol was used to demonstrate continuous magnetophoretic sorting of the two pathogen-bound magnetic bead populations from mixed cultures and from pathogen-spiked chicken pre-enrichment broths under the influence of a Halbach magnet array. For example, in the latter case, a pure population of S. typhimurium-bound Dynabeads (72% recovery) was sorted from a 100 µL mixture containing E. coli 0157-bound Hyglos beads (67% recovery) within 1.2 min in the presence of 0.1% Tween 20. This proof-of-principle study demonstrates how more than one pathogen type can be simultaneously isolated/enriched from a single food pre-enrichment broth (e.g. Universal food enrichment broth).


Subject(s)
Food Microbiology , Immunomagnetic Separation/methods , Microscopy, Electron, Scanning
2.
Micromachines (Basel) ; 7(5)2016 Apr 26.
Article in English | MEDLINE | ID: mdl-30404252

ABSTRACT

Conventional immunoassays offer selective and quantitative detection of a number of biomarkers, but are laborious and time-consuming. Magnetic particle-based assays allow easy and rapid selection of analytes, but still suffer from the requirement of tedious multiple reaction and washing steps. Here, we demonstrate the trapping of functionalised magnetic particles within a microchannel for performing rapid immunoassays by flushing consecutive reagent and washing solutions over the trapped particle plug. Three main studies were performed to investigate the potential of the platform for quantitative analysis of biomarkers: (i) a streptavidin-biotin binding assay; (ii) a sandwich assay of the inflammation biomarker, C-reactive protein (CRP); and (iii) detection of the steroid hormone, progesterone (P4), towards a competitive assay. Quantitative analysis with low limits of detection was demonstrated with streptavidin-biotin, while the CRP and P4 assays exhibited the ability to detect clinically relevant analytes, and all assays were completed in only 15 min. These preliminary results show the great potential of the platform for performing rapid, low volume magnetic particle plug-based assays of a range of clinical biomarkers via an exceedingly simple technique.

3.
Anal Chem ; 86(21): 10552-9, 2014 Nov 04.
Article in English | MEDLINE | ID: mdl-25275437

ABSTRACT

We demonstrate the application of a multilaminar flow platform, in which functionalized magnetic particles are deflected through alternating laminar flow streams of reagents and washing solutions via an external magnet, for the rapid detection of the inflammatory biomarker, C-reactive protein (CRP). The two-step sandwich immunoassay was accomplished in less than 60 s, a vast improvement on the 80-300 min time frame required for enzyme-linked immunosorbent assays (ELISA) and the 50 min necessary for off-chip magnetic particle-based assays. The combination of continuous flow and a stationary magnet enables a degree of autonomy in the system, while a detection limit of 0.87 µg mL(-1) makes it suitable for the determination of CRP concentrations in clinical diagnostics. Its applicability was further proven by assaying real human serum samples and comparing those results to values obtained using standard ELISA tests.


Subject(s)
C-Reactive Protein/analysis , Immunoassay/instrumentation , Magnets/chemistry , Microfluidic Analytical Techniques/instrumentation , Equipment Design , Humans , Immunoassay/economics , Limit of Detection , Magnetic Phenomena , Magnetics/instrumentation , Microfluidic Analytical Techniques/economics
4.
Lab Chip ; 14(13): 2334-43, 2014 Jul 07.
Article in English | MEDLINE | ID: mdl-24832933

ABSTRACT

We have developed a magnetic particle-based assay platform in which functionalised magnetic particles are transferred sequentially through laminated volumes of reagents and washing buffers. Lamination of aqueous liquids is achieved via the use of phaseguide technology; microstructures that control the advancing air-liquid interface of solutions as they enter a microfluidic chamber. This allows manual filling of the device, eliminating the need for external pumping systems, and preparation of the system requires only a few minutes. Here, we apply the platform to two on-chip strategies: (i) a one-step streptavidin-biotin binding assay, and (ii) a two-step C-reactive protein immunoassay. With these, we demonstrate how condensing multiple reaction and washing processes into a single step significantly reduces procedural times, with both assay procedures requiring less than 8 seconds.


Subject(s)
Biotin/chemistry , C-Reactive Protein/analysis , Magnetic Fields , Microfluidic Analytical Techniques , Streptavidin/chemistry , Humans , Immunoassay/instrumentation , Immunoassay/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...