Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Scand J Clin Lab Invest ; 78(4): 281-286, 2018 07.
Article in English | MEDLINE | ID: mdl-29575927

ABSTRACT

Dual antiplatelet therapy is recommended in patients undergoing primary percutaneous coronary intervention (p-PCI) for ST-segment elevation myocardial infarction (STEMI). Pre-analytical variables may influence platelet function analysis results. Our aim was to evaluate the on-treatment platelet reactivity in peripheral artery vs coronary blood in patients with STEMI. We enrolled one hundred and nine patients who consecutively underwent p-PCI at Cardiology Unit of Padua University Hospital between June 2014 and June 2015. Before the procedure, all patients received intravenous aspirin 250 mg and either of the thienopyridines; clopidogrel 600 mg, prasugrel 60 mg or ticagrelor 180 mg. ASPI-test and ADP-test using multiple electrode aggregometry (MEA) were performed in samples collected from both a peripheral artery and the culprit coronary artery. 'Low responders' were patients with an ASPI-test or ADP-test value greater than or equal to a pre-established normal range. No significant differences were observed in ASPI-test values between peripheral (19 (median) [3-49 (10-90 percentiles)] U) vs coronary (12 [1-40] U, p = .06) blood and in ADP-test (40 [14-82] U vs 33 [7-79] U, p =.68) blood. In peripheral blood, fifteen (14%) patients were 'low aspirin' and forty-one (38%) 'low thienopyridines' responders. The prevalence of 'low clopidogrel' responders was higher (45%) than prasugrel (36%) and ticagrelor (33%). Similar results were observed in coronary blood. In patients undergoing p-PCI for STEMI, MEA platelet function observed in coronary arteries was consistent with peripheral artery blood's independently of the antiplatelet drug used. The clinical significance of peripheral and coronary on-aspirin/thienopyridines platelet reactivity needs further clarification.


Subject(s)
Blood Platelets/pathology , Coronary Vessels/pathology , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/blood , ST Elevation Myocardial Infarction/surgery , Adenosine Diphosphate/pharmacology , Arachidonic Acid/pharmacology , Aspirin/therapeutic use , Demography , Female , Humans , Male , Middle Aged , Platelet Aggregation/drug effects , Platelet Aggregation Inhibitors/therapeutic use , Pyridines/pharmacology , Pyridines/therapeutic use , ST Elevation Myocardial Infarction/drug therapy
2.
Phys Chem Chem Phys ; 17(42): 28387-93, 2015 Nov 14.
Article in English | MEDLINE | ID: mdl-26112754

ABSTRACT

Metallic silver, copper, and Ag-Cu nanoparticles (NPs) have been produced by a chemical reduction method. The obtained nanoparticles were characterized by powder X-ray diffraction (XRD) and transmission electron microscopy (TEM). A side-segregated configuration was observed for the one-pot synthesized Ag-Cu NPs, and the melting temperature depression of about 14 °C was found by differential scanning calorimetry (DSC). A comparison between the new experimental data, the literature data on Ag-Cu bimetallic NPs and the corresponding theoretical values obtained from the Ag-Cu nano-sized phase diagram was done, whereas the melting behaviour of Ag and Cu metal nanoparticles was discussed in the framework of the liquid layer model (LLM).

3.
Blood Press ; 24(2): 124-9, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25555153

ABSTRACT

Absolute blood pressure (BP) values are not the only causes of adverse cardiovascular consequences. BP variability (BPV) has also been demonstrated to be a predictor of mortality for cardiovascular events; however, its determinants are still unknown. This study considers 426 subjects with ambulatory BP monitoring (ABPM) measuring 24-h, diurnal and nocturnal absolute BP values and their standard deviations of the mean, along with nocturnal fall, age, sex and current treatment. Patients were divided in two subgroups, controlled and uncontrolled BP, and BPV of patients with "true" and "false" resistant hypertension was also analyzed. Nocturnal and 24-h BPV were higher in the group with uncontrolled hypertension. Multiple regression analysis showed that absolute BP, age, nocturnal fall, but not sex predicted BPV. Patients with "true" resistant hypertension had greater BPV than "false" resistant hypertension patients. Absolute BP resulted as the main determinant of 24-h and nocturnal BPV but not daytime BPV. Also nocturnal BP fall and age resulted as predictors of BPV in treated and untreated patients. Patients with "true" resistant hypertension have a higher BPV, suggesting a higher sympathetic activation. Evidence is still limited regarding the importance of short-term BPV as a prognostic factor and assessment of BPV cannot yet represent a parameter for routine use in clinical practice. Future prospective trials are necessary to define which targets of BPV can be achieved with antihypertensive drugs and whether treatment-induced reduction in BPV is accompanied by a corresponding reduction in cardiovascular events.


Subject(s)
Blood Pressure Monitoring, Ambulatory/methods , Hypertension/physiopathology , Cohort Studies , Female , Humans , Male , Middle Aged , Retrospective Studies
4.
Appl Opt ; 52(36): 8732-46, 2013 Dec 20.
Article in English | MEDLINE | ID: mdl-24513938

ABSTRACT

The space-qualified design of a miniaturized laser for pulsed operation at a wavelength of 1064 nm and at repetition rates up to 10 Hz is presented. This laser consists of a pair of diode-laser pumped, actively q-switched Nd:YAG rod oscillators hermetically sealed and encapsulated in an environment of dry synthetic air. The system delivers at least 300 million laser pulses with 50 mJ energy and 5 ns pulse width (FWHM). It will be launched in 2017 aboard European Space Agency's Mercury Planetary Orbiter as part of the BepiColombo Laser Altimeter, which, after a 6-years cruise, will start recording topographic data from orbital altitudes between 400 and 1500 km above Mercury's surface.

5.
Appl Opt ; 51(20): 4907-15, 2012 Jul 10.
Article in English | MEDLINE | ID: mdl-22781273

ABSTRACT

The accurate co-alignment of the transmitter to the receiver of the BepiColombo Laser Altimeter is a challenging task for which an original alignment concept had to be developed. We present here the design, construction and testing of a large collimator facility built to fulfill the tight alignment requirements. We describe in detail the solution found to attenuate the high energy of the instrument laser transmitter by an original beam splitting pentaprism group. We list the different steps of the calibration of the alignment facility and estimate the errors made at each of these steps. We finally prove that the current facility is ready for the alignment of the flight instrument. Its angular accuracy is 23 µrad.

SELECTION OF CITATIONS
SEARCH DETAIL
...