Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Circ Arrhythm Electrophysiol ; 13(3): e007917, 2020 03.
Article in English | MEDLINE | ID: mdl-32078362

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) using point-by-point radiofrequency energy or single-application one-shot balloons is either technically challenging or have limited ability to accommodate variable patient anatomy to achieve acute and durable pulmonary vein (PV) isolation. A novel ablation system employs low intensity collimated ultrasound (LICU)-guided anatomic mapping and robotic ablation to isolate PVs. In this first-in-human, single-center, multioperator trial, VALUE trial (VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation; NCT03639597) in patients with paroxysmal atrial fibrillation, this LICU system was evaluated to determine its safety, effectiveness in PV isolation, and freedom from recurrent atrial arrhythmias. METHODS: In the enrolled 52 patients with paroxysmal atrial fibrillation, ultrasound M-mode-based left atrial anatomies were successfully created, and ablation was performed under robotic control along an operator-defined lesion path. The LICU system software advanced over the course of the study: the last 13 patients were ablated with enhanced software. RESULTS: Acute PV isolation was achieved in 98% of PVs-using LICU-only in 77.3% (153/198) of PVs and requiring touch-up with a standard radiofrequency ablation catheter in 22.7% (45/198) PVs. The touch-up rate decreased to 5.8% (3/52) in patients undergoing LICU-ablation with enhanced software. Freedom from atrial arrhythmia recurrence was 79.6% (39/49 patients) at 12 months or 92.3% (12/13 patients) with the enhanced software. Major adverse events occurred in 3 patients (5.8%): one had transient diaphragmatic paralysis, one vascular access complication, and one had transient ST-segment elevation from air-embolism, without sequelae. CONCLUSIONS: In this first-in-human study, low- intensity collimated ultrasound-guided anatomic mapping and robotic ablation allows PV isolation with good chronic safety; PV isolation success is improving with device enhancements. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03639597.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Heart Conduction System/physiopathology , Pulmonary Veins/surgery , Surgery, Computer-Assisted/methods , Ultrasonography/instrumentation , Adolescent , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Equipment Design , Female , Follow-Up Studies , Heart Conduction System/diagnostic imaging , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Veins/diagnostic imaging , Recurrence , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...